AXL F AO8 XC 1F - Analog module

Axioline F, Analog output module, Analog outputs: 8, 0 V ... 5 V, -5 V ... 5 V, 0 V ... 10 V, -10 V ... 10 V, 0 mA ... 20 mA, 4 mA ... 20 mA, -20 mA ... 20 mA, connection technology: 2-conductor, transmission speed in the local bus: 100 Mbps, Extreme conditions version, degree of protection: IP20, including bus base module and Axioline F connectors

  • 8 analog, bipolar output channels for the connection of either voltage or current signals
  • Connection of actuators in 2-conductor technology
  • Voltage ranges: 0 V ... 10 V, ±10 V, 0 V ... 5 V, ±5 V
  • Current ranges: 0 mA ... 20 mA, 4 mA ... 20 mA, ±20 mA
  • Short-circuit-proof outputs
  • Device rating plate stored
  • Can be used under extreme ambient conditions
  • Extended temperature range of -40 °C ... +70 °C (see “Tested successfully: use under extreme ambient conditions” in the data sheet)
  • Partially coated PCBs
Technical Specifications

Dimensions

Width53.6 mm
Height126.1 mm
Depth54 mm
Note on dimensionsThe depth applies when a TH 35-7.5 DIN rail is used (in accordance with EN 60715).

Utilization restriction

EMC noteEMC: class A product, see manufacturer's declaration in the download area

Axioline F local bus

Number of interfaces2
Connection MethodBus base module
Transmission Speed100 Mbps

Module

Input address area16 Byte
Output address area16 Byte
Required parameter data 27 Byte
Required configuration data 7 Byte

Analog:

Output nameAnalog outputs
Connection MethodPush-in connection
Connection technology2-conductor
Note regarding the connection technologyshielded, twisted pair
Number of Outputs8
D/A conversion time5 µs
D/A converter resolution16 bit
Protective circuitShort-circuit and overload protection; electronic
Protective circuitTransient protection; Suppressor diode
Data formatsIB IL, S7-compatible
Representation of output values16 bits (15 bits + sign)
Process data update300 µs
Current Output Signal0 mA ... 20 mA
Current Output Signal4 mA ... 20 mA
Current Output Signal-20 mA ... 20 mA
Load/Output Load Current Outputto 500 Ω
Voltage output signal0 V ... 5 V
Voltage output signal-5 V ... 5 V
Voltage output signal0 V ... 10 V
Voltage output signal-10 V ... 10 V
Load/output load voltage output> 2 kΩ
Permissible cable lengthmax. 250 m (Reference cable type LiYCY (TP) n*2*0.5 mm²)

Product properties

Product familyAxioline F
Typeblock modular
Mounting Positionany (observe temperature derating)
Scope of deliveryincluding bus base module and Axioline F connectors
Special PropertiesExtreme conditions version

Insulation characteristics

Overvoltage categoryII (IEC 60664-1, EN 60664-1)
Pollution degree2 (IEC 60664-1, EN 60664-1)

Potentials

Power consumptiontyp. 1.725 W (To UBus and UA, intrinsic power input, no load, output 0 V, up to HW 02)
Power consumptiontyp. 1.4 W (To UBus and UA, intrinsic power input, no load, output 0 V, as of HW 03)
Power consumptionmax. 6.29 W (To UBus and UA, 8 current channels, output 20 mA, up to HW 02)
Power consumptionmax. 5.88 W (To UBus and UA, 8 current channels, output 20 mA, as of HW 03)

Potentials: Axioline F local bus supply (UBus)

Supply Voltage5 V DC (via bus base module)
Current drawmax. 130 mA (up to HW 02)
Current drawmax. 50 mA (from HW 03)
Current drawtyp. 105 mA (up to HW 02)
Current drawtyp. 40 mA (from HW 03)
Power consumptionmax. 0.65 W (up to HW 02)
Power consumptionmax. 0.25 W (from HW 03)
Power consumptiontyp. 0.525 W (up to HW 02)
Power consumptiontyp. 0.2 W (from HW 03)

Potentials: Supply for analog modules (UA)

Supply Voltage24 V DC
Supply Voltage Range19.2 V DC ... 30 V DC (including all tolerances, including ripple)
Current drawmax. 235 mA (8 current channels, 20 mA output)
Current drawtyp. 110 mA (8 voltage channels, 10 V output)
Power consumptionmax. 5.64 W (8 current channels, 20 mA output)
Protective circuitSurge protection; electronic (35 V, 0.5 s)
Protective circuitReverse polarity protection; up to HW 01: polarity protection diodefrom HW 02: parallel diode; with external 5 A fuse (for startup only)
Protective circuitTransient protection; Suppressor diode

Electrical isolation/isolation of the voltage ranges

Test voltage: 5 V supply of the local bus (UBus) / 24 V supply (I/Os)500 V AC, 50 Hz, 1 min.
Test voltage: 5 V supply of the local bus (UBus)/analog outputs500 V AC, 50 Hz, 1 min.
Test voltage: 5 V supply of the local bus (UBus) / functional ground500 V AC, 50 Hz, 1 min.
Test voltage: 24 V supply (I/O)/analog outputs500 V AC, 50 Hz, 1 min.
Test voltage: 24 V supply (I/O) / functional ground500 V AC, 50 Hz, 1 min.
Test voltage: Analog outputs/functional ground500 V AC, 50 Hz, 1 min.

Connection technology

Connection nameAxioline F connector
Note on the connection methodPlease observe the information provided on conductor cross sections in the “Axioline F: system and installation” user manual.

Conductor connection

Connection MethodPush-in connection
Conductor cross section rigid0.2 mm² ... 1.5 mm²
Conductor cross section flexible0.2 mm² ... 1.5 mm²
Conductor cross section AWG24 ... 16
Stripping length8 mm

Axioline F connector

Connection MethodPush-in connection
Note on the connection methodPlease observe the information provided on conductor cross sections in the “Axioline F: system and installation” user manual.
Conductor cross section, rigid0.2 mm² ... 1.5 mm²
Conductor cross section, flexible0.2 mm² ... 1.5 mm²
Conductor cross section AWG24 ... 16
Stripping length8 mm

Ambient conditions

Ambient Temperature (Operation)-25 °C ... 60 °C (Standard)
Ambient Temperature (Operation)-40 °C ... 70 °C (Extended, see section “Tested successfully: use under extreme ambient conditions” in the data sheet.)
Degree of ProtectionIP20
Air pressure (operation)70 kPa ... 106 kPa (up to 3000 m above sea level)
Air pressure (storage/transport)70 kPa ... 106 kPa (up to 3000 m above sea level)
Ambient temperature (storage/transport)-40 °C ... 85 °C
Permissible humidity (operation)5 % ... 95 % (non-condensing)
Permissible humidity (storage/transport)5 % ... 95 % (non-condensing)

Standards and Regulations

Protection classIII (IEC 61140, EN 61140, VDE 0140-1)

Mounting

Mounting TypeDIN rail mounting
Mounting Positionany (observe temperature derating)
Accessories

Why Proax for Phoenix Contact AXL F AO8 XC 1F?

Proax is an authorized distributor of Phoenix Contact AXL F AO8 XC 1F and one of Phoenix Contact's largest distributors in North America. Our highly skilled in-house technical team is ready to assist with any technical needs.

Have a question in mind? to help you get the right product as quickly as possible for your project. We're always here to help!

Short Lead Time
Highly Trained Staff
Live Chat
Technical Support
Local Inventory
60+ Years Experience
Additional Information

Alternate NamesAXLFAO8XC1F
Pack Size1
Recommended

Available for order