Series AXL-F-AI

AXL F AI8 XC 1F - Analog module

Axioline F, Analog input module, Analog inputs: 8, 0 V ... 5 V, -5 V ... 5 V, 0 V ... 10 V, -10 V ... 10 V, 0 mA ... 20 mA, 4 mA ... 20 mA, -20 mA ... 20 mA, connection technology: 2-conductor, transmission speed in the local bus: 100 Mbps, Extreme conditions version, degree of protection: IP20, including bus base module and Axioline F connectors

  • 8 analog, bipolar input channels for the connection of either voltage or current signals
  • Connection of sensors in 2-conductor technology
  • Voltage ranges: 0 V ... 10 V, ±10 V, 0 V ... 5 V, ±5 V
  • Current ranges: 0 mA ... 20 mA, 4 mA ... 20 mA, ±20 mA
  • Device rating plate stored
  • Can be used under extreme ambient conditions
  • Extended temperature range of -40 °C ... +70 °C (see “Tested successfully: use under extreme ambient conditions” in the data sheet)
  • Partially coated PCBs
Technical Specifications

Dimensions

Width53.6 mm
Height126.1 mm
Depth54 mm
Note on dimensionsThe depth applies when a TH 35-7.5 DIN rail is used (in accordance with EN 60715).

Axioline F local bus

Number of interfaces2
Connection MethodBus base module
Transmission Speed100 Mbps

Module

Input address area16 Byte
Output address area16 Byte
Required parameter data 27 Byte
Required configuration data 6 Byte

Analog: General

Input nameAnalog inputs
Description of the inputDifferential inputs, voltage or current can be chosen separately
Number of Inputs8
A/D conversion time2 µs
A/D converter resolution16 bit
Connection MethodPush-in connection
Connection technology2-conductor
Note regarding the connection technologyshielded, twisted pair
Current Input Signal0 mA ... 20 mA
Current Input Signal4 mA ... 20 mA
Current Input Signal-20 mA ... 20 mA
Input resistance current input104 Ω (typical)
Voltage input signal0 V ... 5 V
Voltage input signal-5 V ... 5 V
Voltage input signal0 V ... 10 V
Voltage input signal-10 V ... 10 V
Input resistance of voltage input268 kΩ (typical)
Data formatsIB IL, S7-compatible
Input filter30 Hz, 12 kHz and mean-value generation (can be parameterized)
FilteringRFI filtering / passive TP 1st order
Limit frequency (3 dB)30 Hz
Limit frequency (3 dB)12 kHz (in fast mode)
Common mode voltage range signal - ground-50 V DC ... 50 V DC
Measured value representation16 bits (15 bits + sign bit)
Protective circuitTransient protection of inputs; Suppressor diode
Protective circuitOverload protection of the current inputs; No; ±5.2 V DC, maximum, Imax = 50 mA
Protective circuitOverload protection of the voltage inputs; ±30 V DC, maximum

Product properties

Product familyAxioline F
Typeblock modular
Mounting Positionany (no temperature derating)
Scope of deliveryincluding bus base module and Axioline F connectors
Special PropertiesExtreme conditions version

Insulation characteristics

Overvoltage categoryII (IEC 60664-1, EN 60664-1)
Pollution degree2 (IEC 60664-1, EN 60664-1)

Electrical properties

Maximum power dissipation for nominal condition4.2 W

Potentials

Power consumptiontyp. 1.255 W (at UBus and UA (from HW 02))
Power consumptiontyp. 1.365 W (at UBus and UA (up to HW 01))
Power consumptionmax. 1.62 W (at UBus and UA (from HW 02))
Power consumptionmax. 1.605 W (at UBus and UA (up to HW 01))

Potentials: Axioline F local bus supply (UBus)

Supply Voltage5 V DC (via bus base module)
Current drawmax. 130 mA (up to HW 01)
Current drawmax. 60 mA (from HW 02)
Current drawtyp. 105 mA (up to HW 01)
Current drawtyp. 45 mA (from HW 02)
Power consumptionmax. 650 mW (up to HW 01)
Power consumptionmax. 300 mW (from HW 02)
Power consumptiontyp. 525 mW (up to HW 01)
Power consumptiontyp. 225 mW (from HW 02)

Potentials: Supply for analog modules (UA)

Supply Voltage24 V DC
Supply Voltage Range19.2 V DC ... 30 V DC (including all tolerances, including ripple)
Current drawmax. 55 mA (from HW 02)
Current drawmax. 45 mA (up to HW 01)
Current drawtyp. 43 mA (from HW 02)
Current drawtyp. 35 mA (up to HW 01)
Power consumptionmax. 1.32 W (from HW 02)
Power consumptionmax. 1.08 W (up to HW 01)
Protective circuitSurge protection; electronic (35 V, 0.5 s)
Protective circuitReverse polarity protection; Polarity protection diode
Protective circuitTransient protection; Suppressor diode

Electrical isolation/isolation of the voltage ranges

Test voltage: 5 V supply of the local bus (UBus) / 24 V supply (I/Os)500 V AC, 50 Hz, 1 min.
Test voltage: 5 V supply of the local bus (UBus)/analog inputs500 V AC, 50 Hz, 1 min.
Test voltage: 5 V supply of the local bus (UBus) / functional ground500 V AC, 50 Hz, 1 min.
Test voltage: 24 V supply (I/O)/analog inputs500 V AC, 50 Hz, 1 min.
Test voltage: 24 V supply (I/O) / functional ground500 V AC, 50 Hz, 1 min.
Test voltage: Analog inputs/functional ground500 V AC, 50 Hz, 1 min.

Connection technology

Connection nameAxioline F connector
Note on the connection methodPlease observe the information provided on conductor cross sections in the “Axioline F: system and installation” user manual.

Conductor connection

Connection MethodPush-in connection
Conductor cross section rigid0.2 mm² ... 1.5 mm²
Conductor cross section flexible0.2 mm² ... 1.5 mm²
Conductor cross section AWG24 ... 16
Stripping length8 mm

Axioline F connector

Connection MethodPush-in connection
Note on the connection methodPlease observe the information provided on conductor cross sections in the “Axioline F: system and installation” user manual.
Conductor cross section, rigid0.2 mm² ... 1.5 mm²
Conductor cross section, flexible0.2 mm² ... 1.5 mm²
Conductor cross section AWG24 ... 16
Stripping length8 mm

Ambient conditions

Ambient Temperature (Operation)-25 °C ... 60 °C (Standard)
Ambient Temperature (Operation)-40 °C ... 70 °C (Extended, see section “Tested successfully: use under extreme ambient conditions” in the data sheet.)
Degree of ProtectionIP20
Air pressure (operation)70 kPa ... 106 kPa (up to 3000 m above sea level)
Air pressure (storage/transport)70 kPa ... 106 kPa (up to 3000 m above sea level)
Ambient temperature (storage/transport)-40 °C ... 85 °C
Permissible humidity (operation)5 % ... 95 % (non-condensing)
Permissible humidity (storage/transport)5 % ... 95 % (non-condensing)

Standards and Regulations

Protection classIII (IEC 61140, EN 61140, VDE 0140-1)

Mounting

Mounting TypeDIN rail mounting
Mounting Positionany (no temperature derating)
Accessories

Why Proax for Phoenix Contact AXL F AI8 XC 1F?

Proax is an authorized distributor of Phoenix Contact AXL F AI8 XC 1F and one of Phoenix Contact's largest distributors in North America. Our highly skilled in-house technical team is ready to assist with any technical needs.

Have a question in mind? to help you get the right product as quickly as possible for your project. We're always here to help!

Short Lead Time
Highly Trained Staff
Live Chat
Technical Support
Local Inventory
60+ Years Experience
Additional Information

Alternate NamesAXLFAI8XC1F
Pack Size1
Recommended

Available for order

Phoenix Contact Availability