Official Distributor
SKU
MPN
TRIO-PS-2G/1500DC/24DC/8
Weight
1.546 kg
Series TRIO-PS
TRIO-PS-2G/1500DC/24DC/8 - DC/DC converter
Primary-switched TRIO POWER DC/DC converter with Push-in connection for DIN rail mounting, input: 1,500 V DC, output: 24 V DC / 8 A
Technical Specifications
DC operation
Nominal input voltage range | 600 V DC ... 1500 V DC |
Input voltage range | 600 V DC ... 1500 V DC -15 % ... +10 % |
Wide-range input | no |
Input voltage range DC | 600 V DC ... 1500 V DC -15 % ... +10 % |
Electric strength, max. | ≤ 1800 V DC 1 s |
Typical national grid voltage | 1500 V DC |
Typical national grid voltage | 600 V DC |
Voltage type of supply voltage | DC |
Inrush current integral (I2t) | typ. 0.15 A2s |
Current consumption | typ. 0.35 A (600 V DC) |
Current consumption | typ. 0.145 A (1500 V DC) |
Recommended breaker for input protection | 2 A (gPV) |
Recommended fuse for input protection | 1500 V DC |
Output data
Efficiency | typ. 91.5 % (600 V DC) |
Efficiency | typ. 90.9 % (900 V DC) |
Efficiency | typ. 89 % (1500 V DC) |
Nominal Output Voltage | 24 V DC ±1 % |
Setting range of the output voltage (USet) | 24 V DC ... 28 V DC (> 24 V DC, constant capacity restricted) |
Nominal output current (IN) | 8 A |
Derating | > 60 °C ... 70 °C (2.5 %/K) |
Feedback voltage resistance | ≤ 35 V DC |
Protection against overvoltage at the output (OVP) | ≤ 30 V DC |
Control deviation | < 1 % (change in load, static 10 % ... 90 %) |
Control deviation | < 3 % (Dynamic load change 10 % ... 90 %, 10 Hz) |
Control deviation | < 0.1 % (change in input voltage ±10 %) |
Residual ripple | < 40 mVPP (Ripple) |
Residual ripple | < 50 mVPP (Noise) |
Short-circuit-proof | yes |
No-load proof | yes |
Output Power | 192 W |
Maximum no-load power dissipation | < 9 W |
Power loss nominal load max. | < 24 W |
Rise time | ≤ 30 ms (UOUT (10 % ... 90 %)) |
Connection in parallel | yes, for redundancy and increased capacity |
Connection in series | No |
Signal: DC OK
Continuous load current | 100 mA |
Signal relay 13/14
Default | closed |
Digital | 30 V AC 30 V DC 100 mA |
Input
Connection Method | Push-in connection |
Conductor cross section, rigid min. | 1 mm² |
Conductor cross section, rigid max. | 4 mm² |
Conductor cross section flexible min. | 1 mm² |
Conductor cross section flexible max. | 2.5 mm² |
Single conductor/flexible terminal point with ferrule with plastic sleeve, min. | 1 mm² |
Single conductor/flexible terminal point with ferrule with plastic sleeve, max. | 2.5 mm² |
Single conductor/flexible terminal point with ferrule without plastic sleeve, min. | 1 mm² |
Single conductor/flexible terminal point with ferrule without plastic sleeve, max. | 2.5 mm² |
Conductor cross section AWG min. | 18 |
Conductor cross section AWG max. | 12 |
Stripping length | 10 mm |
Output
Connection Method | Push-in connection |
Conductor cross section, rigid min. | 1 mm² |
Conductor cross section, rigid max. | 4 mm² |
Conductor cross section flexible min. | 1 mm² |
Conductor cross section flexible max. | 2.5 mm² |
Single conductor/flexible terminal point with ferrule with plastic sleeve, min. | 0.2 mm² |
Single conductor/flexible terminal point with ferrule with plastic sleeve, max. | 1.5 mm² |
Single conductor/flexible terminal point with ferrule without plastic sleeve, min. | 0.2 mm² |
Single conductor/flexible terminal point with ferrule without plastic sleeve, max. | 1.5 mm² |
Conductor cross section AWG min. | 18 |
Conductor cross section AWG max. | 12 |
Stripping length | 10 mm |
Signal
Connection Method | Push-in connection |
Conductor cross section, rigid min. | 0.2 mm² |
Conductor cross section, rigid max. | 1.5 mm² |
Conductor cross section flexible min. | 0.2 mm² |
Conductor cross section flexible max. | 1.5 mm² |
Single conductor/flexible terminal point with ferrule with plastic sleeve, min. | 0.2 mm² |
Single conductor/flexible terminal point with ferrule with plastic sleeve, max. | 1.5 mm² |
Single conductor/flexible terminal point with ferrule without plastic sleeve, min. | 0.2 mm² |
Single conductor/flexible terminal point with ferrule without plastic sleeve, max. | 1.5 mm² |
Conductor cross section AWG min. | 24 |
Conductor cross section AWG max. | 16 |
Stripping length | 8 mm |
Signaling
Types of signaling | LED |
Types of signaling | Floating signal contact |
Signal output: LED status indicator
Signalization designation | DC OK |
Status display | "DC OK" LED green |
Note on status display | UOUT > 21.5 V: LED lights up |
Color | green |
DC OK | UOUT > 0.9 x UN (UN = 24 V DC) |
Electrical properties
Number of phases | 1.00 |
Insulation voltage input/output | 4.2 kV DC (type test) |
Insulation voltage input/output | 2.6 kV DC (routine test) |
Product properties
Product family | TRIO POWER |
MTBF (IEC 61709, SN 29500) | > 1500000 h (25 °C) |
MTBF (IEC 61709, SN 29500) | > 900000 h (40 °C) |
MTBF (IEC 61709, SN 29500) | > 400000 h (60 °C) |
Insulation characteristics
Protection class | I |
Degree of pollution | 2 |
Dimensions
Width | 88.5 mm |
Height | 130 mm |
Depth | 160 mm |
Installation dimensions
Installation distance right/left | 0 mm / 0 mm (≤ 40°C) |
Installation distance right/left (active) | 10 mm / 10 mm (≤ 70 °C) |
Installation distance top/bottom | 50 mm / 50 mm (≤ 70 °C) |
Installation distance top/bottom (active) | 50 mm / 50 mm (≤ 70 °C) |
Mounting
Mounting Type | DIN rail mounting |
Assembly instructions | alignable: horizontally 0 mm (≤ 40 °C) 10 mm (≤ 70 °C), vertically 50 mm |
Mounting Position | horizontal DIN rail NS 35, EN 60715 |
With protective coating | No |
Material specifications
Flammability rating according to UL 94 (housing / terminal blocks) | V0 |
Housing Material | Metal |
Type of housing | Aluminum (AlMg3) |
Hood version | Polycarbonate |
Ambient conditions
Degree of Protection | IP20 |
Ambient Temperature (Operation) | -25 °C ... 70 °C (>60°C derating: 1.2%/K) |
Ambient temperature (storage/transport) | -40 °C ... 85 °C |
Ambient temperature (start-up type tested) | -40 °C |
Maximum altitude | ≤ 4000 m (> 2000 m, Derating: 10 %/1000 m) |
Climatic class | 3K3 (in acc. with EN 60721) |
Max. permissible relative humidity (operation) | ≤ 95 % (at 25 °C, non-condensing) |
Shock | 18 ms, 30g, in each space direction (according to IEC 60068-2-27) |
Vibration (Operation) | < 15 Hz, amplitude ±2.5 mm (according to IEC 60068-2-6) |
Vibration (Operation) | 15 Hz ... 150 Hz, 2.3g, 90 min. |
Standards and Regulations
Standard - Electrical safety | EN 62109-1:2011 |
Standard – Safety extra-low voltage | IEC 62109-1:2011 (SELV) |
Standard - Safe isolation | DIN VDE 0100-410 |
Overvoltage category
IEC 62109-1 | II |
Approvals
UL approvals | UL 62109-1:2014 |
EMC data
Low Voltage Directive | Conformance with Low Voltage Directive 2014/35/EC |
Noise immunity | EN 61000-6-2:2005 |
Electromagnetic compatibility | Conformance with EMC Directive 2014/30/EU |
Conducted noise emission | EN 55016 |
Conducted noise emission | EN 61000-6-4 (Class A) |
Noise emission | EN 55016 |
Noise emission | EN 61000-6-4 (Class A) |
Electrostatic discharge
Standards/regulations | EN 61000-4-2 |
Contact discharge | 4 kV (Test Level 2) |
Discharge in air | 8 kV (Test Level 3) |
Comments | Criterion A |
Electromagnetic HF field
Standards/regulations | EN 61000-4-3 |
Frequency Range | 80 MHz ... 1 GHz |
Test field strength | 20 V/m (> Test intensity 3) |
Frequency Range | 1 GHz ... 2 GHz |
Test field strength | 10 V/m (Test Level 3) |
Frequency Range | 2 GHz ... 3 GHz |
Test field strength | 10 V/m (Test Level 3) |
Comments | Criterion A |
Fast transients (burst)
Standards/regulations | EN 61000-4-4 |
Input | 4 kV (Test Level 4 - asymmetrical) |
Output | 2 kV (Test Level 3 - asymmetrical) |
Signal | 1 kV (Test Level 3 - asymmetrical) |
Comments | Criterion B |
Surge voltage load (surge)
Standards/regulations | EN 61000-4-5 |
Input | 1 kV (Test Level 3 - symmetrical) |
Input | 2 kV (Test Level 3 - asymmetrical) |
Output | 0.5 kV (Test Level 2 - symmetrical) |
Output | 0.5 kV (Test Level 1 - asymmetrical) |
Signal | 1 kV (Test Level 2 - asymmetrical) |
Comments | Criterion B |
Conducted interference
Standards/regulations | EN 61000-4-6 |
Input/Output | asymmetrical |
Frequency Range | 0.15 MHz ... 80 MHz |
Comments | Criterion A |
Voltage | 10 V (Test Level 3) |
Voltage dips
Standards/regulations | EN 61000-4-11 |
Emitted interference
Standards/regulations | EN 61000-6-4 |
Radio interference voltage in acc. with EN 55011 | EN 55011 (EN 55022) Class A industrial area of application |
Emitted radio interference in acc. with EN 55011 | EN 55011 (EN 55022) Class A industrial area of application |
Criteria
Criterion A | Normal operating behavior within the specified limits. |
Criterion B | Temporary impairment to operational behavior that is corrected by the device itself. |
Accessories
Why Proax for Phoenix Contact 1075240?
Proax is an authorized distributor of Phoenix Contact 1075240 and one of Phoenix Contact's largest distributors in North America. Our highly skilled in-house technical team is ready to assist with any technical needs.
Have a question in mind? to help you get the right product as quickly as possible for your project. We're always here to help!
Short Lead Time
Highly Trained Staff
Live Chat
Technical Support
Local Inventory
60+ Years Experience
Additional Information
Pack Size | 1 |
Recommended
- TRIO-PS/1AC/48DC/ 5, TRIO POWER power supplies with standard functionalityTRIO POWER is particularly suited to standard machine production, thanks to 1- and 3-phase versions up to 960 W. The wide-range input and the international approval package enable worldwide use.The robust metal housing, the high electric strength, and the wide temperature range ensure a high level of power supply reliability.