Series TRIO-PS

TRIO-PS-2G/3AC/72DC/14 - Power supply unit

Primary-switched TRIO power supply for DIN rail mounting, input: 3-phase, output: 72 V DC/14 A, dynamic boost, tool-free fast connection technology for rigid and flexible conductors with ferrule

Technical Specifications

AC operation

Network TypeStar network
Nominal input voltage range3x 400 V AC ... 500 V AC
Input voltage range3x 400 V AC ... 500 V AC -20 % ... +15 %
Typical national grid voltage3x 400 V AC
Typical national grid voltage3x 480 V AC
Voltage type of supply voltageAC
Inrush Current≤ 30 A (typical)
Inrush current integral (I2t)< 1.1 A2s
Inrush current limitation35 A (after 1 ms)
AC frequency range50 Hz ... 60 Hz
Frequency range (fN)50 Hz ... 60 Hz ±5 Hz
Mains buffering time> 10 ms (400 V AC)
Mains buffering time> 20 ms (480 V AC)
Current consumption3x 1.9 A (400 V AC)
Current consumption3x 1.7 A (500 V AC)
Nominal Power Consumption1335.1 VA
Protective circuitTransient surge protection; Varistor
Power factor (cos phi)0.77
Typical response time< 1 s
Input fuse6.3 A (internal (device protection))
Recommended breaker for input protection10 A ... 16 A (Characteristics B, C, D, K)
Discharge current to PE< 3.5 mA
Discharge current to PE< 2.5 mA (550 V AC, 60 Hz)

Output data

Efficiency> 94.6 % (400 V AC)
Efficiency> 94.3 % (480 V AC)
Output characteristicU/I with dynamic load reserve
Nominal Output Voltage72 V DC ±1 %
Setting range of the output voltage (USet)70 V DC ... 85 V DC (> 72 V DC, constant capacity restricted)
Nominal output current (IN)14 A
Dynamic Boost (IDyn.Boost)21 A (5 s)
Derating> 60 °C ... 70 °C (2.5 %/K)
Feedback voltage resistance< 105 V DC
Protection against overvoltage at the output (OVP)≤ 105 V DC
Control deviation< 1 % (change in load, static 10 % ... 90 %)
Control deviation< 3 % (Dynamic load change 10 % ... 90 %, 10 Hz)
Control deviation< 0.1 % (change in input voltage ±10 %)
Residual ripple≤ 300 mVPP
Short-circuit-proofyes
No-load proofyes
Output Power1008 W
Output Power1512 W
Maximum no-load power dissipation< 7 W (400 V AC)
Power loss nominal load max.< 58 W (400 V AC)
Short-circuit current< 23.5 A DC (Permanent)
Rise time≤ 2 ms (UOUT (10 % ... 90 %))
Connection in parallelyes
Connection in seriesyes

Signal: DC OK

Continuous load current100 mA

Signal relay 13/14

Defaultclosed
Digital30 V AC 30 V DC 100 mA

Input

Connection MethodPush-in connection
Conductor cross section, rigid min.0.2 mm²
Conductor cross section, rigid max.4 mm²
Conductor cross section flexible min.0.2 mm²
Conductor cross section flexible max.4 mm²
Single conductor/flexible terminal point with ferrule with plastic sleeve, min.0.2 mm²
Single conductor/flexible terminal point with ferrule with plastic sleeve, max.2.5 mm²
Single conductor/flexible terminal point with ferrule without plastic sleeve, min.0.2 mm²
Single conductor/flexible terminal point with ferrule without plastic sleeve, max.2.5 mm²
Conductor cross section AWG min.24
Conductor cross section AWG max.12
Stripping length10 mm

Output

Connection MethodPush-in connection
Conductor cross section, rigid min.0.75 mm²
Conductor cross section, rigid max.16 mm²
Conductor cross section flexible min.0.75 mm²
Conductor cross section flexible max.16 mm²
Single conductor/flexible terminal point with ferrule with plastic sleeve, min.0.75 mm²
Single conductor/flexible terminal point with ferrule with plastic sleeve, max.10 mm²
Single conductor/flexible terminal point with ferrule without plastic sleeve, min.0.75 mm²
Single conductor/flexible terminal point with ferrule without plastic sleeve, max.16 mm²
Conductor cross section AWG min.20
Conductor cross section AWG max.4
Stripping length18 mm

Signal

Connection MethodPush-in connection
Conductor cross section, rigid min.0.2 mm²
Conductor cross section, rigid max.0.75 mm²
Conductor cross section flexible min.0.2 mm²
Conductor cross section flexible max.1.5 mm²
Single conductor/flexible terminal point with ferrule with plastic sleeve, min.0.2 mm²
Single conductor/flexible terminal point with ferrule with plastic sleeve, max.0.75 mm²
Single conductor/flexible terminal point with ferrule without plastic sleeve, min.0.2 mm²
Single conductor/flexible terminal point with ferrule without plastic sleeve, max.1 mm²
Conductor cross section AWG min.24
Conductor cross section AWG max.18
Stripping length8 mm

Signaling

Types of signalingLED
Types of signalingFloating signal contact

Signal output: LED status indicator

Signalization designationDC OK
Status displayLED
Colorgreen
DC OKUOUT > 0.95 x UN (UN = 72 V DC)

Electrical properties

Number of phases3.00
Insulation voltage input/output3 kV AC (type test)
Insulation voltage input/output1.5 kV AC (routine test)

Product properties

Product familyTRIO POWER
MTBF (IEC 61709, SN 29500)> 1730000 h (25 °C)
MTBF (IEC 61709, SN 29500)> 1051000 h (40 °C)
MTBF (IEC 61709, SN 29500)> 510000 h (60 °C)

Insulation characteristics

Protection classI (in closed control cabinet)
Degree of pollution2

Dimensions

Width110 mm
Height130 mm
Depth160 mm

Installation dimensions

Installation distance right/left0 mm / 0 mm
Installation distance top/bottom50 mm / 50 mm

Mounting

Mounting TypeDIN rail mounting
Assembly instructionsalignable: horizontally 0 mm (≤ 40 °C) 10 mm (≤ 70 °C), vertically 50 mm
Mounting Positionhorizontal DIN rail NS 35, EN 60715
With protective coatingNo

Material specifications

Flammability rating according to UL 94 (housing / terminal blocks)V0
Housing MaterialPlastic
Type of housingAluminum (AlMg3)
Hood versionPolycarbonate

Ambient conditions

Degree of ProtectionIP20
Ambient Temperature (Operation)-25 °C ... 70 °C (> 60 °C Derating: 2,5 %/K)
Ambient temperature (storage/transport)-40 °C ... 85 °C
Ambient temperature (start-up type tested)-40 °C
Maximum altitude≤ 4000 m (> 2000 m, Derating: 10 %/1000 m)
Climatic class3K3 (in acc. with EN 60721)
Max. permissible relative humidity (operation)≤ 95 % (at 25 °C, non-condensing)
Shock11 ms, 15 g, in each space direction (according to IEC 60068-2-27)
Vibration (Operation)< 15 Hz, amplitude ±2.5 mm (according to IEC 60068-2-6)
Vibration (Operation)15 Hz ... 150 Hz, 0.7g, 90 min.

Standards and Regulations

Standard – Limitation of mains harmonic currentsEN 61000-3-2
Standard - Electrical safetyIEC 61010-2-201
Standard - Safe isolationDIN VDE 0100-410
Standard - Safety of transformersEN 61558-2-16 (air clearances and creepage distances only)

Overvoltage category

EN 61010-1II (≤ 2000 m)

Approvals

UL approvalsUL/C-UL Listed UL 61010-1

Conformity/Approvals

SIL in accordance with IEC 615080

EMC data

Low Voltage DirectiveConformance with Low Voltage Directive 2014/35/EC
Interference emissionInterference emission in accordance with EN 61000-6-3 (residential and commercial) and EN 61000-6-4 (industrial)
EMC requirements for noise immunityEN 61000-6-1
EMC requirements for noise immunityEN 61000-6-2
Electromagnetic compatibilityConformance with EMC Directive 2014/30/EU
Conducted noise emissionEN 55016-2-1
Conducted noise emissionEN 61000-6-4 (Class A)
Noise emissionEN 55011 (EN 55022)
Noise emissionEN 55016-2-3
Noise emissionEN 61000-6-4 (Class A)

Harmonic currents

Standards/regulationsEN 55016-2-3
Standards/regulationsEN 61000-3-2 (Class A)

Flicker

Standards/regulationsEN 61000-3-3
Standards/regulationsEN 61000-3-3

Electrostatic discharge

Standards/regulationsEN 61000-4-2
Contact discharge6 kV (Test Level 3)
Discharge in air8 kV (Test Level 3)
CommentsCriterion A

Electromagnetic HF field

Standards/regulationsEN 61000-4-3
Frequency Range80 MHz ... 1 GHz
Test field strength10 V/m (Test Level 3)
Frequency Range1 GHz ... 2 GHz
Test field strength10 V/m (Test Level 3)
Frequency Range2 GHz ... 6 GHz
Test field strength10 V/m (Test Level 3)
CommentsCriterion A

Fast transients (burst)

Standards/regulationsEN 61000-4-4
Input4 kV (Test Level 3 - asymmetrical)
Output2 kV (Test Level 3 - asymmetrical)
Signal2 kV (Test Level 3 - asymmetrical)
CommentsCriterion A

Surge voltage load (surge)

Standards/regulationsEN 61000-4-5
Input1 kV (Test Level 1 - symmetrical)
Input2 kV (Test Level 1 - asymmetrical)
Output0.5 kV (Test Level 1 - symmetrical)
Output0.5 kV (Test Level 1 - asymmetrical)
Signal1 kV (Test Level 2 - asymmetrical)
CommentsCriterion B

Conducted interference

Standards/regulationsEN 61000-4-6
Input/Outputasymmetrical
Frequency Range0.15 MHz ... 80 MHz
CommentsCriterion A
Voltage10 V (Test Level 3)

Voltage dips

Standards/regulationsEN 61000-4-11
Voltage400 V AC
Frequency50 Hz
Voltage dip70 %
Number of periods25 periods
CommentsCriterion A
Voltage dip40 %
Number of periods10 periods
CommentsCriterion A
Voltage dip0 %
Number of periods1 period
CommentsCriterion A

Emitted interference

Standards/regulationsEN 61000-6-3
Radio interference voltage in acc. with EN 55011EN 55011 (EN 55022) Class B, area of application: Industry and residential
Emitted radio interference in acc. with EN 55011EN 55011 (EN 55022) Class B, area of application: Industry and residential

Criteria

Criterion ANormal operating behavior within the specified limits.
Criterion BTemporary impairment to operational behavior that is corrected by the device itself.
Criterion CTemporary adverse effects on the operating behavior, which the device corrects automatically or which can be restored by actuating the operating elements.

Why Proax for Phoenix Contact TRIO-PS-2G/3AC/72DC/14?

Proax is an authorized distributor of Phoenix Contact TRIO-PS-2G/3AC/72DC/14 and one of Phoenix Contact's largest distributors in North America. Our highly skilled in-house technical team is ready to assist with any technical needs.

Have a question in mind? to help you get the right product as quickly as possible for your project. We're always here to help!

Short Lead Time
Highly Trained Staff
Live Chat
Technical Support
Local Inventory
60+ Years Experience
Additional Information

Alternate NamesTRIOPS2G3AC72DC14
Pack Size1
Recommended

Available for order