Proax

Currency
0 Items
proax logo
Cart
Phoenix ContactOfficial Distributor

By Phoenix Contact

SKU
MPN
2903160
Series TRIO-PS

TRIO-PS-2G/1AC/48DC/10 - Power supply unit

Primary-switched TRIO POWER power supply with push-in connection for DIN rail mounting, input: single phase, output: 48 V DC/10 A

  • Save time and costs, thanks to the Push-in connection and narrow design
  • Increase system availability, thanks to dynamic boost with 150% of the nominal current for five seconds
  • Maximum flexibility due to the wide temperature range from -25°C to +70°C and device startup at -40°C
  • Electrically robust, thanks to high electric strength
  • Mechanically robust, thanks to high vibration and shock resistance
Technical Specifications

AC operation

Network TypeStar network
Nominal input voltage range100 V AC ... 240 V AC
Input voltage range100 V AC ... 240 V AC -15 % ... +10 %
Electric strength, max.≤ 300 V AC 15 s
Typical national grid voltage120 V AC
Typical national grid voltage230 V AC
Voltage type of supply voltageAC/DC
Inrush Current20 A (at 25 °C)
Inrush current integral (I2t)< 0.7 A2s
Inrush current limitationtyp. 20 A (after 1 ms)
AC frequency range50 Hz ... 60 Hz ±10 %
Mains buffering timetyp. 10 ms (120 V AC)
Mains buffering timetyp. 15 ms (230 V AC)
Current consumption5.6 A (100 V AC)
Current consumption5.4 A (120 V AC)
Current consumption2.6 A (230 V AC)
Current consumption2.4 A (240 V AC)
Nominal Power Consumption604.7 VA
Protective circuitTransient surge protection; Varistor
Power factor (cos phi)0.85
Typical response time< 1 s
Input fuse10 A (internal (device protection))
Recommended breaker for input protection10 A ... 16 A (Characteristics B, C, D, K)
Discharge current to PE< 3.5 mA

DC operation

Nominal input voltage range110 V DC ... 250 V DC
Input voltage range99 V DC ... 275 V DC
Switch-on voltage≥ 93 V DC
Shut-down voltage< 85 V DC
Voltage type of supply voltageAC/DC
Mains buffering time> 20 ms (230 V AC)
Current consumption5 A (110 V DC)
Current consumption2.2 A (250 V DC)

Output data

Efficiency> 93 % (for 230 V AC and nominal values)
Output characteristicU/I with dynamic load reserve
Nominal Output Voltage48 V DC ±1 %
Setting range of the output voltage (USet)36 V DC ... 55 V DC (> 48 V DC, constant capacity restricted)
Nominal output current (IN)10 A
Dynamic Boost (IDyn.Boost)15 A (5 s)
Derating> 60 °C ... 70 °C (2.5 %/K)
Feedback voltage resistance≤ 60 V DC
Protection against overvoltage at the output (OVP)≤ 60 V DC
Control deviation< 1 % (change in load, static 10 % ... 90 %)
Control deviation< 3 % (Dynamic load change 10 % ... 90 %, 10 Hz)
Control deviation< 0.1 % (change in input voltage ±10 %)
Residual ripple< 50 mVPP (with nominal values)
Short-circuit-proofyes
No-load proofyes
Output Power480 W
Output Power720 W
Peak switching voltages nominal load< 1000 mVPP
Maximum no-load power dissipation< 5.7 W (230 V)
Power loss nominal load max.< 44 W
Rise time≤ 30 ms (UOUT (10 % ... 90 %))
Connection in parallelyes, for redundancy and increased capacity
Connection in seriesyes

Signal: DC OK

Maximum Switching Voltage30 V AC/DC
Continuous load current100 mA

Input

Connection MethodPush-in connection
Conductor cross section, rigid min.0.2 mm²
Conductor cross section, rigid max.4 mm²
Conductor cross section flexible min.0.2 mm²
Conductor cross section flexible max.2.5 mm²
Conductor cross section AWG min.24
Conductor cross section AWG max.12
Stripping length10 mm

Output

Connection MethodPush-in connection
Conductor cross section, rigid min.0.2 mm²
Conductor cross section, rigid max.10 mm²
Conductor cross section flexible min.0.2 mm²
Conductor cross section flexible max.6 mm²
Conductor cross section AWG min.24
Conductor cross section AWG max.8
Stripping length15 mm

Signal

Connection MethodPush-in connection
Conductor cross section, rigid min.0.2 mm²
Conductor cross section, rigid max.1.5 mm²
Conductor cross section flexible min.0.2 mm²
Conductor cross section flexible max.1.5 mm²
Conductor cross section AWG min.24
Conductor cross section AWG max.16
Stripping length8 mm

Signaling

Types of signalingLED
Types of signalingFloating signal contact

Signal output: LED status indicator

Signalization designationDC OK
Status display“DC OK” LED
Colorgreen

Electrical properties

Number of phases1.00
Insulation voltage input/output3 kV AC
Insulation voltage input/output1.5 kV AC

Product properties

Product familyTRIO POWER
MTBF (IEC 61709, SN 29500)> 1800000 h (25 °C)
MTBF (IEC 61709, SN 29500)> 800000 h (40 °C)
MTBF (IEC 61709, SN 29500)> 480000 h (60 °C)

Insulation characteristics

Protection classI (in closed control cabinet)
Degree of pollution2

Dimensions

Width68 mm
Height130 mm
Depth160 mm

Installation dimensions

Installation distance right/left0 mm / 0 mm
Installation distance top/bottom50 mm / 50 mm

Mounting

Mounting TypeDIN rail mounting
Assembly instructionsalignable: horizontally 0 mm (≤ 40 °C) 10 mm (≤ 70 °C), vertically 50 mm
Mounting Positionhorizontal DIN rail NS 35, EN 60715
With protective coatingNo

Material specifications

Flammability rating according to UL 94 (housing / terminal blocks)V0
Housing MaterialMetal
Type of housingAluminum (AlMg3)
Hood versionPolycarbonate

Ambient conditions

Degree of ProtectionIP20
Ambient Temperature (Operation)-25 °C ... 70 °C (> 60 °C Derating: 2,5 %/K)
Ambient temperature (storage/transport)-40 °C ... 85 °C
Ambient temperature (start-up type tested)-40 °C
Maximum altitude≤ 5000 m (> 2000 m, Derating: 10 %/1000 m)
Climatic class3K3 (in acc. with EN 60721)
Max. permissible relative humidity (operation)≤ 95 % (at 25 °C, non-condensing)
Shock18 ms, 30g, in each space direction (according to IEC 60068-2-27)
Vibration (Operation)< 15 Hz, amplitude ±2.5 mm (according to IEC 60068-2-6)
Vibration (Operation)15 Hz ... 150 Hz, 4g, 90 min.

Standards and Regulations

Rail applicationsEN 50121-4
Standard – Electronic equipment for use in electrical power installations and their assembly into electrical power installationsEN 50178/VDE 0160 (PELV)
Standard – Limitation of mains harmonic currentsEN 61000-3-2
Standard - Electrical safetyIEC 62368-1 (SELV)
Standard – Safety extra-low voltageIEC 60950-1 (SELV) and EN 60204-1 (PELV)
Standard - Safe isolationDIN VDE 0100-410
Standard - Safety of transformersEN 61558-2-16 (air clearances and creepage distances only)

Approvals

UL approvalsUL Listed UL 508
UL approvalsUL/C-UL Recognized UL 60950-1
UL approvalsUL ANSI/ISA-12.12.01 Class I, Division 2, Groups A, B, C, D (Hazardous Location)

Conformity/Approvals

SIL in accordance with IEC 615080

EMC data

Low Voltage DirectiveConformance with Low Voltage Directive 2014/35/EC
EMC requirements for noise emissionEN 61000-6-3
EMC requirements for noise emissionEN 61000-6-4
EMC requirements for noise immunityEN 61000-6-1
EMC requirements for noise immunityEN 61000-6-2
Electromagnetic compatibilityConformance with EMC Directive 2014/30/EU
Noise emissionEN 55011 (EN 55022)

Electrostatic discharge

Standards/regulationsEN 61000-4-2
Contact discharge6 kV (Test Level 4)
Discharge in air8 kV (Test Level 4)
CommentsCriterion A

Electromagnetic HF field

Standards/regulationsEN 61000-4-3
Frequency Range80 MHz ... 1 GHz
Test field strength10 V/m (Test Level 3)
Frequency Range1 GHz ... 2 GHz
Test field strength10 V/m (Test Level 3)
Frequency Range2 GHz ... 3 GHz
Test field strength10 V/m (Test Level 3)
CommentsCriterion A

Fast transients (burst)

Standards/regulationsEN 61000-4-4
Input4 kV (Test Level 4 - asymmetrical)
Output2 kV (Test Level 3 - asymmetrical)
Signal1 kV (Test Level 2 - asymmetrical)
CommentsCriterion A

Surge voltage load (surge)

Standards/regulationsEN 61000-4-5
Input1 kV (Test Level 1 - symmetrical)
Input2 kV (Test Level 1 - asymmetrical)
Output0.5 kV (Test Level 1 - symmetrical)
Output0.5 kV (Test Level 1 - asymmetrical)
Signal0.5 kV (Test Level 2 - asymmetrical)
CommentsCriterion B

Conducted interference

Standards/regulationsEN 61000-4-6
I/O/Sasymmetrical
Frequency Range0.15 MHz ... 80 MHz
CommentsCriterion A
Voltage10 V (Test Level 3)

Emitted interference

Standards/regulationsEN 61000-6-3
Radio interference voltage in acc. with EN 55011EN 55011 (EN 55022) Class B, area of application: Industry and residential
Emitted radio interference in acc. with EN 55011EN 55011 (EN 55022) Class B, area of application: Industry and residential

Criteria

Criterion ANormal operating behavior within the specified limits.
Criterion BTemporary impairment to operational behavior that is corrected by the device itself.
Accessories

Why Proax for Phoenix Contact TRIO-PS-2G/1AC/48DC/10?

Proax is an authorized distributor of Phoenix Contact TRIO-PS-2G/1AC/48DC/10 and one of Phoenix Contact's largest distributors in North America. Our highly skilled in-house technical team is ready to assist with any technical needs.

Have a question in mind? to help you get the right product as quickly as possible for your project. We're always here to help!

Short Lead Time
Highly Trained Staff
Live Chat
Technical Support
Local Inventory
60+ Years Experience
Additional Information

Alternate NamesTRIOPS2G1AC48DC10
Pack Size1
Recommended

Available for order