Official Distributor
SKU
MPN
TRIO-DIODE/48DC/2X10/1X20
Weight
0.516 kg
This product is Not Cancellable/Not Returnable
Series TRIO-DIODE
TRIO-DIODE/48DC/2X10/1X20 - Redundancy module
Redundancy module with function monitoring, 48 V DC, 2x 10 A, 1x 20 A
- Save energy
- Permanent monitoring of redundancy
- Consistent redundancy up to the load
Technical Specifications
DC operation
Nominal input voltage range | 48 V DC |
Input voltage range | 30 V DC ... 56 V DC |
Voltage type of supply voltage | DC |
Reverse polarity protection | < yes60 V |
Nominal input current (IN) | 2x 10 A (-25 °C ... 55 °C) |
Nominal input current (IN) | 1x 20 A (-25 °C ... 55 °C) |
Maximum current Imax | 2x 15 A (-25 °C ... 40 °C) |
Maximum current Imax | 1x 30 A (-25 °C ... 40 °C) |
Transient surge protection | Varistor |
Voltage drop, input/output | approx. 0.65 V |
Output data
Efficiency | > 97 % |
Nominal Output Voltage | UIn - 0,65 V |
Nominal output current (IN) | 20 A (Increasing power) |
Nominal output current (IN) | 10 A (Redundancy) |
Derating | 55 °C ... 70 °C (2.5 %/K) |
Maximum no-load power dissipation | 7 W (IOUT = 10 A) |
Power loss nominal load max. | 14 W (IOUT = 20 A) |
Connection in series | No |
Signal: Floating redundancy OK
Output description | Contact closed when UIN1 & UIN2 > 28 V |
Maximum Switching Voltage | 30 V AC/DC |
Maximum Inrush Current | ≤ 100 mA (short-circuit-proof) |
Input
Connection Method | Screw connection |
Conductor cross section, rigid min. | 0.2 mm² |
Conductor cross section, rigid max. | 2.5 mm² |
Conductor cross section flexible min. | 0.2 mm² |
Conductor cross section flexible max. | 2.5 mm² |
Conductor cross section AWG min. | 24 |
Conductor cross section AWG max. | 14 |
Stripping length | 9 mm |
Screw thread | M2,5 |
Tightening torque, min | 0.4 Nm |
Tightening torque max | 0.5 Nm |
Output
Connection Method | Screw connection |
Conductor cross section, rigid min. | 0.5 mm² |
Conductor cross section, rigid max. | 6 mm² |
Conductor cross section flexible min. | 0.5 mm² |
Conductor cross section flexible max. | 4 mm² |
Conductor cross section AWG min. | 20 |
Conductor cross section AWG max. | 10 |
Stripping length | 14 mm |
Screw thread | M3 |
Tightening torque, min | 0.5 Nm |
Tightening torque max | 0.6 Nm |
Signal
Conductor cross section, rigid min. | 0.2 mm² |
Conductor cross section, rigid max. | 2.5 mm² |
Conductor cross section flexible min. | 0.2 mm² |
Conductor cross section flexible max. | 2.5 mm² |
Conductor cross section AWG min. | 24 |
Conductor cross section AWG max. | 14 |
Screw thread | M2,5 |
Tightening torque, min | 0.4 Nm |
Tightening torque max | 0.5 Nm |
Signaling
Types of signaling | LED |
Types of signaling | Relay contact |
Signal output: Floating redundancy OK
Status display | LED redundancy OK |
Note on status display | UIN1& UIN2 > 28 V: LED lights up green |
Electrical properties
Insulation voltage input, output / housing | 500 V |
Product properties
Product family | TRIO DIODE |
MTBF (IEC 61709, SN 29500) | > 10000000 h (40 °C) |
LED | yes |
Insulation characteristics
Protection class | III |
Degree of pollution | 2 |
Dimensions
Width | 32 mm |
Height | 130 mm |
Depth | 115 mm |
Horizontal pitch | 1.8 Div. |
Installation dimensions
Installation distance right/left | 0 mm / 0 mm |
Installation distance top/bottom | 50 mm / 50 mm |
Mounting
Mounting Type | DIN rail mounting |
Assembly instructions | alignable: horizontally 0 mm, vertically 50 mm |
Mounting Position | horizontal DIN rail NS 35, EN 60715 |
Material specifications
Housing Material | Metal |
Housing Material | Steel sheet, zinc-plated |
Type of housing | Steel sheet, zinc-plated |
Side element version | Aluminum |
Ambient conditions
Degree of Protection | IP20 |
Ambient Temperature (Operation) | -25 °C ... 70 °C (> 55° C derating : 2.5%/K) |
Ambient temperature (storage/transport) | -40 °C ... 85 °C |
Climatic class | 3K3 (in acc. with EN 60721) |
Max. permissible relative humidity (operation) | ≤ 95 % (at 25 °C, non-condensing) |
Shock | 15g in all directions in acc. with IEC 60068-2-27 |
Vibration (Operation) | < 15 Hz, amplitude ±2.5 mm |
Vibration (Operation) | 15 Hz ... 150 Hz, 2.3g tv = 90 min. |
Standards and Regulations
Standard – Electronic equipment for use in electrical power installations and their assembly into electrical power installations | EN 50178/VDE 0160 (PELV) |
Standard - Electrical safety | EN 60950-1/VDE 0805 (SELV) |
Standard – Protection against shock currents, basic requirements for protective separation in electrical equipment | EN 50178 |
Standard – Safety extra-low voltage | IEC 60950-1 (SELV) and EN 60204-1 (PELV) |
Standard - Safe isolation | DIN VDE 0100-410 |
Approvals
UL approvals | UL/C-UL listed UL 508 |
UL approvals | UL/C-UL Recognized UL 60950-1 |
Conformity/Approvals
SIL in accordance with IEC 61508 | 0 |
EMC data
Low Voltage Directive | Conformance with Low Voltage Directive 2014/35/EC |
EMC requirements for noise emission | EN 61000-6-3 |
EMC requirements for noise emission | EN 61000-6-4 |
EMC requirements for noise immunity | EN 61000-6-1 |
EMC requirements for noise immunity | EN 61000-6-2 |
Electromagnetic compatibility | Conformance with EMC Directive 2014/30/EU |
Electrostatic discharge
Standards/regulations | EN 61000-4-2 |
Contact discharge | 6 kV (Test Level 3) |
Discharge in air | 8 kV (Test Level 3) |
Comments | Criterion B |
Electromagnetic HF field
Standards/regulations | EN 61000-4-3 |
Frequency Range | 80 MHz ... 1 GHz |
Test field strength | 10 V/m (Test Level 3) |
Frequency Range | 1 GHz ... 2 GHz |
Test field strength | 10 V/m (Test Level 3) |
Frequency Range | 2 GHz ... 3 GHz |
Test field strength | 10 V/m (Test Level 3) |
Comments | Criterion A |
Fast transients (burst)
Standards/regulations | EN 61000-4-4 |
Input | 2 kV (Test Level 3 - asymmetrical) |
Output | 2 kV (Test Level 3 - asymmetrical) |
Comments | Criterion B |
Surge voltage load (surge)
Standards/regulations | EN 61000-4-5 |
Input | 0.5 kV (Test Level 1 - symmetrical) |
Input | 0.5 kV (Test Level 1 - asymmetrical) |
Output | 0.5 kV (Test Level 1 - symmetrical) |
Output | 0.5 kV (Test Level 1 - asymmetrical) |
Comments | Criterion B |
Conducted interference
Standards/regulations | EN 61000-4-6 |
I/O/S | asymmetrical |
Frequency Range | 0.15 MHz ... 80 MHz |
Comments | Criterion A |
Voltage | 10 V (Test Level 3) |
Emitted interference
Standards/regulations | EN 61000-6-3 |
Radio interference voltage in acc. with EN 55011 | EN 55011 (EN 55022) Class B, area of application: Industry and residential |
Emitted radio interference in acc. with EN 55011 | EN 55011 (EN 55022) Class B, area of application: Industry and residential |
Criteria
Criterion A | Normal operating behavior within the specified limits. |
Criterion B | Temporary impairment to operational behavior that is corrected by the device itself. |
Why Proax for Phoenix Contact 2866527?
Proax is an authorized distributor of Phoenix Contact 2866527 and one of Phoenix Contact's largest distributors in North America. Our highly skilled in-house technical team is ready to assist with any technical needs.
Have a question in mind? to help you get the right product as quickly as possible for your project. We're always here to help!
Short Lead Time
Highly Trained Staff
Live Chat
Technical Support
Local Inventory
60+ Years Experience
Additional Information
Pack Size | 1 |
Recommended