TRIO-PS-2G/3AC/24DC/40 - Power supply unit

Primary-switched TRIO power supply for DIN rail mounting, input: 3-phase, output: 24 V DC/40 A, dynamic boost, tool-free fast connection technology for solid and stranded conductors with ferrule

  • Save time and costs, thanks to the Push-in connection and narrow design
  • Increase system availability, thanks to dynamic boost with 150% of the nominal current for five seconds
  • Maximum flexibility due to the wide temperature range from -25°C to +70°C and device startup at -40°C
  • Electrically robust, thanks to high electric strength
  • Mechanically robust, thanks to high vibration and shock resistance
Technical Specifications

AC operation

Network TypeStar network
Nominal input voltage range3x 400 V AC ... 500 V AC
Input voltage range3x 400 V AC ... 500 V AC -20 % ... +15 %
Typical national grid voltage3x 400 V AC
Typical national grid voltage3x 480 V AC
Voltage type of supply voltageAC
Inrush current integral (I2t)≤ 1.1 A2s
Inrush current limitation35 A (after 1 ms)
AC frequency range50 Hz ... 60 Hz
Frequency range (fN)50 Hz ... 60 Hz ±5 Hz
Mains buffering time> 10 ms (400 V AC)
Mains buffering time> 20 ms (480 V AC)
Current consumption3x 1.9 A (400 V AC)
Current consumption3x 1.7 A (500 V AC)
Nominal Power Consumption1335.1 VA
Protective circuitTransient surge protection; Varistor
Power factor (cos phi)0.77
Typical response time< 1 s
Input fuse6.3 A (internal (device protection))
Recommended breaker for input protection10 A ... 16 A (Characteristics B, C, D, K)
Discharge current to PE< 3.5 mA
Discharge current to PE< 2.5 mA (550 V AC, 60 Hz)
POWER factor> 0.7 (400 V AC)
POWER factor> 0.7 (480 V AC)

Output data

Efficiencytyp. 93 % (400 V AC)
Efficiencytyp. 93.3 % (480 V AC)
Output characteristicU/I with dynamic load reserve
Nominal Output Voltage24 V DC ±1 %
Setting range of the output voltage (USet)24 V DC ... 28 V DC (> 24 V DC, constant capacity restricted)
Nominal output current (IN)40 A
Dynamic Boost (IDyn.Boost)60 A (5 s)
Derating> 60 °C ... 70 °C (2.5 %/K)
POWER factor> 0.7 (400 V AC)
POWER factor> 0.7 (480 V AC)
Feedback voltage resistance< 35 V
Protection against overvoltage at the output (OVP)≤ 30 V DC
Control deviation< 1 % (change in load, static 10 % ... 90 %)
Control deviation< 3 % (Dynamic load change 10 % ... 90 %, 10 Hz)
Control deviation< 0.1 % (change in input voltage ±10 %)
Residual ripple≤ 50 mVPP
Short-circuit-proofyes
No-load proofyes
Output Power960 W
Output Power1440 W
Maximum no-load power dissipationtyp. 14 W (400 V AC)
Maximum no-load power dissipationtyp. 17 W (480 V AC)
Power loss nominal load max.< 70 W (480 V AC)
Power loss nominal load max.typ. 72 W (480 V AC)
Short-circuit current< 48 A DC (Permanent)
Rise time≤ 1 s (UOUT (10 % ... 90 %))
Connection in parallelyes, for redundancy and increased capacity
Connection in seriesyes

Signal: DC OK

Continuous load current100 mA

Signal relay 13/14

Defaultclosed
Digital30 V AC 30 V DC 100 mA

Input

Connection MethodPush-in connection
Conductor cross section, rigid min.0.2 mm²
Conductor cross section, rigid max.4 mm²
Conductor cross section flexible min.0.2 mm²
Conductor cross section flexible max.2.5 mm²
Single conductor/terminal point, stranded, with ferrule, min.0.2 mm²
Single conductor/terminal point, stranded, with ferrule, max.2.5 mm²
Conductor cross section AWG min.24
Conductor cross section AWG max.12
Stripping length10 mm

Output

Connection MethodPush-in connection
Conductor cross section, rigid min.0.75 mm²
Conductor cross section, rigid max.16 mm²
Conductor cross section flexible min.0.75 mm²
Conductor cross section flexible max.10 mm²
Single conductor/terminal point, stranded, with ferrule, min.0.75 mm²
Single conductor/terminal point, stranded, with ferrule, max.10 mm²
Conductor cross section AWG min.20
Conductor cross section AWG max.4
Stripping length18 mm

Signal

Connection MethodPush-in connection
Conductor cross section, rigid min.0.2 mm²
Conductor cross section, rigid max.1.5 mm²
Conductor cross section flexible min.0.2 mm²
Conductor cross section flexible max.1.5 mm²
Single conductor/terminal point, stranded, with ferrule, min.0.2 mm²
Single conductor/terminal point, stranded, with ferrule, max.1.5 mm²
Conductor cross section AWG min.24
Conductor cross section AWG max.16
Stripping length8 mm

Signaling

Types of signalingLED
Types of signalingFloating signal contact

Signal output: LED status indicator

Signalization designationDC OK
Status displayLED
Colorgreen
DC OKUOUT > 0.9 x UN (UN = 24 V DC)

Electrical properties

Number of phases3.00
Insulation voltage input/output3 kV AC (type test)
Insulation voltage input/output1.5 kV AC (routine test)

Product properties

Product familyTRIO POWER
MTBF (IEC 61709, SN 29500)> 1730000 h (25 °C)
MTBF (IEC 61709, SN 29500)> 1051000 h (40 °C)
MTBF (IEC 61709, SN 29500)> 510000 h (60 °C)

Insulation characteristics

Protection classI (in closed control cabinet)
Degree of pollution2

Dimensions

Width110 mm
Height130 mm
Depth160 mm

Installation dimensions

Installation distance right/left0 mm / 0 mm
Installation distance top/bottom50 mm / 50 mm

Mounting

Mounting TypeDIN rail mounting
Assembly instructionsalignable: horizontally 0 mm (≤ 40 °C) 10 mm (≤ 70 °C), vertically 50 mm
Mounting Positionhorizontal DIN rail NS 35, EN 60715
With protective coatingNo

Material specifications

Flammability rating according to UL 94 (housing / terminal blocks)V0
Housing MaterialMetal
Type of housingAluminum (AlMg3)
Hood versionPolycarbonate

Ambient conditions

Degree of ProtectionIP20
Ambient Temperature (Operation)-25 °C ... 70 °C (> 60 °C Derating: 2,5 %/K)
Ambient temperature (storage/transport)-40 °C ... 85 °C
Ambient temperature (start-up type tested)-40 °C
Maximum altitude≤ 4000 m (> 2000 m, Derating: 10 %/1000 m)
Climatic class3K3 (in acc. with EN 60721)
Max. permissible relative humidity (operation)≤ 95 % (at 25 °C, non-condensing)
Shock11 ms, 15 g, in each space direction (according to IEC 60068-2-27)
Vibration (Operation)DNV GL CG-0339 / Class B2 Hz - 100 Hz resonance search, 90 min. in resonance,2 Hz - 13.2 Hz, ±1 mm amplitude,13.2 Hz - 100 Hz, 0.7g acceleration

Standards and Regulations

Rail applicationsEN 50121-4
Standard – Electronic equipment for use in electrical power installations and their assembly into electrical power installationsEN 50178/VDE 0160 (PELV)
Standard – Limitation of mains harmonic currentsEN 61000-3-2
Standard - Electrical safetyIEC 62368-1 (SELV)
Standard – Safety extra-low voltageIEC 62368-1 (SELV) und EN 60204-1 (PELV)
Standard - Safe isolationDIN VDE 0100-410
Standard - Safety of power supply units up to 1100 V (insulation distances)DIN EN 61558-2-16

Overvoltage category

EN 60950-1II
EN 62477-1III

Approvals

UL approvalsUL Listed UL 508
UL approvalsUL/C-UL Recognized UL 60950-1

Conformity/Approvals

SIL in accordance with IEC 615080

EMC data

Low Voltage DirectiveConformance with Low Voltage Directive 2014/35/EC
EMC requirements for noise emissionEN 61000-6-3
EMC requirements for noise emissionEN 61000-6-4
EMC requirements for noise immunityEN 61000-6-1
EMC requirements for noise immunityEN 61000-6-2
Electromagnetic compatibilityConformance with EMC Directive 2014/30/EU
Conducted noise emissionEN 55016
Conducted noise emissionEN 61000-6-3 (Class B)
Noise emissionEN 55011 (EN 55022)
Noise emissionEN 55016
Noise emissionEN 61000-6-3 (Class B)

Harmonic currents

Frequency RangeClass A, B

Flicker

Frequency Range0 kHz ... 2 kHz

Electrostatic discharge

Standards/regulationsEN 61000-4-2
Contact discharge6 kV (Test Level 3)
Discharge in air8 kV (Test Level 3)
CommentsCriterion A

Electromagnetic HF field

Standards/regulationsEN 61000-4-3
Frequency Range80 MHz ... 6 GHz
Test field strength10 V/m (Test Level 3)
Frequency Range80 MHz ... 6 GHz
Test field strength10 V/m (Test Level 3)
Frequency Range80 MHz ... 6 GHz
Test field strength10 V/m (Test Level 3)
CommentsCriterion A

Fast transients (burst)

Standards/regulationsEN 61000-4-4
Input4 kV (Test Level 3 - asymmetrical)
Output2 kV (Test Level 3 - asymmetrical)
Signal2 kV (Test Level 3 - asymmetrical)
CommentsCriterion A

Surge voltage load (surge)

Standards/regulationsEN 61000-4-5
Input1 kV (Test Level 1 - symmetrical)
Input2 kV (Test Level 1 - asymmetrical)
Output0.5 kV (Test Level 1 - symmetrical)
Output0.5 kV (Test Level 1 - asymmetrical)
Signal1 kV (Test Level 2 - asymmetrical)
CommentsCriterion B

Conducted interference

Standards/regulationsEN 61000-4-6
Input/Outputasymmetrical
Frequency Range0.15 MHz ... 80 MHz
CommentsCriterion A
Voltage10 V (Test Level 3)

Voltage dips

Standards/regulationsEN 61000-4-11
Voltage230 V AC
Frequency50 Hz

Emitted interference

Standards/regulationsEN 61000-6-3
Radio interference voltage in acc. with EN 55011EN 55011 (EN 55022) Class B, area of application: Industry and residential
Emitted radio interference in acc. with EN 55011EN 55011 (EN 55022) Class B, area of application: Industry and residential

Criteria

Criterion ANormal operating behavior within the specified limits.
Criterion BTemporary impairment to operational behavior that is corrected by the device itself.
Criterion CTemporary adverse effects on the operating behavior, which the device corrects automatically or which can be restored by actuating the operating elements.
Accessories

Why Proax for Phoenix Contact 2903156?

Proax is an authorized distributor of Phoenix Contact 2903156 and one of Phoenix Contact's largest distributors in North America. Our highly skilled in-house technical team is ready to assist with any technical needs.

Have a question in mind? to help you get the right product as quickly as possible for your project. We're always here to help!

Short Lead Time
Highly Trained Staff
Live Chat
Technical Support
Local Inventory
60+ Years Experience
Additional Information

Pack Size1
Recommended

Not in stock

Request lead time or order—we'll ensure quick delivery

Phoenix Contact Availability