SKU
MPN
CBMC E4 24DC/1-4A NO
Weight
0.133 kg
Series CBMC-E4

CBMC E4 24DC/1-4A NO - Electronic circuit breaker

Multi-channel electronic circuit breaker for protecting four loads at 24 V DC in the event of overload and short circuit. With electronic locking of the set nominal currents. For installation on DIN rails.

  • Easy device replacement without replanning, thanks to compact design and options for individual adjustments
  • Circuits can be adjusted without any tools by means of one single pushable LED button
  • Optimum protection for cables and sensors as well as NEC Class 2 circuits by means of an additional internal output fuse
  • Reliable protection against unintentional adjustment of current values, thanks to electronic locking
  • Status LEDs in traffic light colors enable instantaneous determination of operating states
Technical Specifications

General

NoteRepeated hard short circuits can reduce the melting integral of the integrated backup fuse.

Product properties

Product familyCBMC
TypeDIN rail module, one-piece
Number of Positions1
No. of channels4

Insulation characteristics

Protection classIII
Pollution degree2

General

Operating Voltage18 V DC ... 30 V DC
Rated voltage24 V DC
Rated current INmax. 16 A DC (IN+)
Rated current INmax. 40 A DC (per terminal position when bridging additional devices via IN+)
Rated current IN1 / 2 / 3 / 4 A DC (adjustable per output channel)
Rated current (pre-adjusted)4 A
Rated surge voltage0.5 kV
Tripping methodE (electronic)
Feedback resistancemax. 35 V DC
Required backup fuseOnly required if Imax of the power supply > the short-circuit switching capacity. Integrated failsafe element.
Short-circuit switching capacity300 A
Dielectric strengthmax. 35 V DC (Load circuit)
Fuseelectronic
Efficiency> 99 %
Closed circuit current I0typ. 25 mA
Power dissipationtyp. 0.6 W (No-load operation)
Power dissipation< 4 W (Nominal operation)
Module initialization time1.6 s
Waiting time after switch off of a channel5 s (at overload / short circuit)
Measuring tolerance I± 15 %
MTBF (IEC 61709, SN 29500)11764705 h (at 25 °C with 21 % load)
MTBF (IEC 61709, SN 29500)5319148 h (at 40°C with 34.25% load)
MTBF (IEC 61709, SN 29500)846023 h (at 60°C with 100% load)
Fail-safe element4 A DC (per output channel)

Load circuit

Shutdown time≤ 10 ms (for short circuit > 2.0 x IN)
Shutdown time1 s (1.2 ... 2.0 x IN)
Undervoltage switch-off≤ 17.8 V DC (active)
Undervoltage switch-off≥ 18.8 V DC (inactive)
Overvoltage switch-off≥ 30.5 V DC (active)
Overvoltage switch-off≤ 29.5 V DC (inactive)
Max. capacitive load30000 µF (Depending on the current setting and the short-circuit current available)

Indicator/remote signaling

Connection nameRemote indication circuit
Switching functionN/O contact
Operating Voltage0 V DC ... 30 V DC
Operating current100 mA DC

Main circuit IN+

Connection MethodPush-in connection
Stripping length15 mm
Conductor cross section rigid0.2 mm² ... 10 mm²
Conductor cross section AWG24 ... 8
Conductor cross section, flexible, with ferrule, with plastic sleeve0.25 mm² ... 4 mm²
Conductor cross section flexible, with ferrule without plastic sleeve0.25 mm² ... 6 mm²

Main circuit IN-

Connection MethodPush-in connection
Stripping length10 mm
Conductor cross section rigid0.2 mm² ... 2.5 mm²
Conductor cross section AWG24 ... 12
Conductor cross section, flexible, with ferrule, with plastic sleeve0.25 mm² ... 1.5 mm²
Conductor cross section flexible, with ferrule without plastic sleeve0.25 mm² ... 2.5 mm²

Main circuit OUT

Connection MethodPush-in connection
Stripping length10 mm
Conductor cross section rigid0.2 mm² ... 2.5 mm²
Conductor cross section AWG24 ... 12
Conductor cross section, flexible, with ferrule, with plastic sleeve0.25 mm² ... 1.5 mm²
Conductor cross section flexible, with ferrule without plastic sleeve0.25 mm² ... 2.5 mm²

Remote indication circuit

Stripping length10 mm
Conductor cross section rigid0.2 mm² ... 2.5 mm²
Conductor cross section AWG24 ... 12
Conductor cross section, flexible, with ferrule, with plastic sleeve0.25 mm² ... 1.5 mm²
Conductor cross section flexible, with ferrule without plastic sleeve0.25 mm² ... 2.5 mm²

Signaling

Channel LED offoff (Channel switched off)
Channel LED yellowlit (Channel switched on, channel load > 80% )
Channel LED yellowflashing (Programming mode active)
Channel LED greenlit (Channel switched on)
Channel LED redlit (Channel switched off, over- or undervoltage active)
Channel LED redON temporarily (Channel switched off, 5 s cool-down phase, overload or short-circuit release)
Channel LED redflashing (Channel switched off, ready to be switched back on, overload or short-circuit release)
Channel LED redtwo flashes (Channel switched off, device total current limit 40 A exceeded)

Dimensions

Width36 mm
Height90 mm
Depth98 mm (incl. DIN rail 7.5 mm)

Material specifications

Colorlight grey (RAL 7035)
MaterialPC
MaterialPA 6.6
MaterialPA 6.3T
MaterialPOM
Flammability rating according to UL 94V-0

Ambient conditions

Degree of ProtectionIP20
Ambient Temperature (Operation)-25 °C ... 60 °C
Ambient temperature (storage/transport)-40 °C ... 70 °C
Altitude≤ 3000 m up to 52 °C (amsl)
Altitude≤ 4000 m up to 46 °C (amsl)
Humidity test96 h, 95 % RH, 40 °C
Shock (operation)30g (IEC 60068-2-27, Test Ea)
Vibration (Operation)10 Hz ... 57.6 Hz (Amplitude ±0.35 mm; in accordance with IEC 60068-2-6, Test Fc)
Vibration (Operation)57.6 Hz … 150 Hz (Acceleration 5g; in accordance with IEC 60068-2-6, Test Fc)

UL approval

IdentificationUL/C-UL Listed UL 508
IdentificationUL Recognized UL 2367
IdentificationNEC Class 2 according to UL 1310

Corrosive gas test

IdentificationISA S71.04.2013 G3 Harsh Group A

Standards and Regulations

Standards/specificationsEN 61000-6-2
NoteEMC – Immunity for industrial areas
Standards/specificationsEN 61000-6-3
NoteEMC – Emission for residential, business and commercial properties and small operations
Standards/specificationsEN 60068-2-6
NoteEnvironmental influences – Vibrations (sinusoidal)
Standards/specificationsEN 60068-2-27
NoteEnvironmental influences – Shocks
Standards/specificationsEN 60068-2-78
NoteEnvironmental influences – Moisture and heat, constant
Standards/specificationsEN 50178
NoteEquipping power installations with electronic equipment

Mounting

Mounting TypeDIN rail: 35 mm

Why Proax for Phoenix Contact 2906031?

Proax is an authorized distributor of Phoenix Contact 2906031 and one of Phoenix Contact's largest distributors in North America. Our highly skilled in-house technical team is ready to assist with any technical needs.

Have a question in mind? to help you get the right product as quickly as possible for your project. We're always here to help!

Short Lead Time
Highly Trained Staff
Live Chat
Technical Support
Local Inventory
60+ Years Experience
Additional Information

Pack Size1
Recommended

Not in stock

Request lead time or order—we'll ensure quick delivery

Phoenix Contact Availability