Official Distributor
SKU
MPN
2910411
Weight
0.139 kg
Series CBMC-E4
CBMC E4 24DC/1-10A IOL - Electronic circuit breaker
Multi-channel electronic circuit breaker with IO-Link interface for protecting four loads at 24 V DC in the event of overload and short circuit. With electronic locking of the set nominal currents. For installation on DIN rails.
- System transparency, thanks to comprehensive diagnostics capabilities
- Worldwide access to the device, thanks to integration into your IO-Link infrastructure
- Secure locking, thanks to interlock
- Plan service calls more efficiently since regular service interval calls can be performed conveniently via the interface.
- Convenient error diagnostics, thanks to precise error categorization and recording
- Autonomous operation since the device is fully functional even without the IO-Link interface connection
Technical Specifications
General
Note | Repeated hard short circuits can reduce the melting integral of the integrated backup fuse. |
Product properties
Product family | CBMC |
Type | DIN rail module, one-piece |
Number of Positions | 1 |
No. of channels | 4 |
Insulation characteristics
Protection class | III |
Pollution degree | 2 |
General
Operating Voltage | 18 V DC ... 30 V DC |
Rated voltage | 24 V DC |
Rated current IN | max. 40 A DC (IN+) |
Rated current IN | max. 40 A DC (per terminal position when bridging additional devices via IN+) |
Rated current IN | 1 / 2 / 3 / 4 / 5 / 6 / 7 / 8 / 9 / 10 A DC (adjustable per output channel) |
Rated current (pre-adjusted) | 4 A |
Rated surge voltage | 0.5 kV |
Tripping method | E (electronic) |
Feedback resistance | max. 35 V DC |
Required backup fuse | Only required if Imax of the power supply > the short-circuit switching capacity. Integrated failsafe element. |
Short-circuit switching capacity | 300 A |
Dielectric strength | max. 35 V DC (Load circuit) |
Fuse | electronic |
Efficiency | > 99 % |
Closed circuit current I0 | typ. 25 mA |
Power dissipation | typ. 0.6 W (No-load operation) |
Power dissipation | < 9 W (Nominal operation) |
Module initialization time | 1.6 s |
Waiting time after switch off of a channel | 5 s (at overload / short circuit) |
Measuring tolerance I | ± 15 % |
Temperature derating | 24 A DC (at 60 °C) |
Temperature derating | 28 A DC (at 54 °C) |
Temperature derating | 32 A DC (at 47 °C) |
Temperature derating | 36 A DC (at 41 °C) |
Temperature derating | 40 A DC (at 35 °C) |
MTBF (IEC 61709, SN 29500) | 6896552 h (at 25 °C with 21 % load) |
MTBF (IEC 61709, SN 29500) | 2597403 h (at 40°C with 34.25% load) |
MTBF (IEC 61709, SN 29500) | 443066 h (at 35 °C with 100 % load) |
Fail-safe element | 15 A DC (per output channel) |
Load circuit
Shutdown time | ≤ 10 ms (for short circuit > 2.0 x IN) |
Shutdown time | 1 s (1.2 ... 2.0 x IN) |
Undervoltage switch-off | ≤ 17.8 V DC (active) |
Undervoltage switch-off | ≥ 18.8 V DC (inactive) |
Overvoltage switch-off | ≥ 30.5 V DC (active) |
Overvoltage switch-off | ≤ 29.5 V DC (inactive) |
Max. capacitive load | 40000 µF (Depending on the current setting and the short-circuit current available) |
Main circuit IN+
Connection Method | Push-in connection |
Stripping length | 15 mm |
Conductor cross section rigid | 0.2 mm² ... 10 mm² |
Conductor cross section AWG | 24 ... 8 |
Conductor cross section, flexible, with ferrule, with plastic sleeve | 0.25 mm² ... 4 mm² |
Conductor cross section flexible, with ferrule without plastic sleeve | 0.25 mm² ... 6 mm² |
Main circuit IN-
Connection Method | Push-in connection |
Stripping length | 10 mm |
Conductor cross section rigid | 0.2 mm² ... 2.5 mm² |
Conductor cross section AWG | 24 ... 12 |
Conductor cross section, flexible, with ferrule, with plastic sleeve | 0.25 mm² ... 1.5 mm² |
Conductor cross section flexible, with ferrule without plastic sleeve | 0.25 mm² ... 2.5 mm² |
Main circuit OUT
Connection Method | Push-in connection |
Stripping length | 10 mm |
Conductor cross section rigid | 0.2 mm² ... 2.5 mm² |
Conductor cross section AWG | 24 ... 12 |
Conductor cross section, flexible, with ferrule, with plastic sleeve | 0.25 mm² ... 1.5 mm² |
Conductor cross section flexible, with ferrule without plastic sleeve | 0.25 mm² ... 2.5 mm² |
IO-Link
Connection Method | Push-in connection |
Stripping length | 10 mm |
Conductor cross section rigid | 0.2 mm² ... 1.5 mm² |
Conductor cross section AWG | 24 ... 16 |
Conductor cross section, flexible, with ferrule, with plastic sleeve | 0.25 mm² ... 0.75 mm² |
Conductor cross section flexible, with ferrule without plastic sleeve | 0.25 mm² ... 1.5 mm² |
Interface type | IO-Link |
Specification | V1.1 |
Reverse polarity protection | yes |
Transmission Speed | 230.4 kbps (COM3) |
Cycle Time | min. 40 ms |
Amount of Process Data | 8 Byte (Input data) |
Amount of Process Data | 3 Byte (Output data) |
Nominal voltage for I/O supply | 24 V DC |
Current consumption | max. 30 mA (IO-Link L+) |
IO-Link Vendor ID | 176dec, 00 B0hex |
IO-Link Device ID | 393504dec, 06 01 20hex |
Signaling
IO-Link LED off | off (No communication) |
IO-Link LED green | flashing (IO-Link connection exists) |
Channel LED off | off (Channel switched off) |
Channel LED yellow | lit (Channel switched on, channel load > 80% ) |
Channel LED yellow | flashing (Programming mode active) |
Channel LED green | lit (Channel switched on) |
Channel LED red | lit (Channel switched off, over- or undervoltage active) |
Channel LED red | ON temporarily (Channel switched off, 5 s cool-down phase, overload or short-circuit release) |
Channel LED red | flashing (Channel switched off, ready to be switched back on, overload or short-circuit release) |
Channel LED red | two flashes (Channel switched off, device total current limit 40 A exceeded) |
Dimensions
Width | 36 mm |
Height | 90 mm |
Depth | 98 mm (incl. DIN rail 7.5 mm) |
Material specifications
Color | light grey (RAL 7035) |
Material | PC |
Material | PA 6.6 |
Material | PA 6.3T |
Material | POM |
Flammability rating according to UL 94 | V-0 |
Ambient conditions
Degree of Protection | IP20 |
Ambient Temperature (Operation) | -25 °C ... 60 °C |
Ambient temperature (storage/transport) | -40 °C ... 70 °C |
Altitude | ≤ 3000 m up to 52 °C (amsl) |
Altitude | ≤ 4000 m up to 46 °C (amsl) |
Humidity test | 96 h, 95 % RH, 40 °C |
Shock (operation) | 30g (IEC 60068-2-27, Test Ea) |
Vibration (Operation) | 10 Hz ... 57.6 Hz (Amplitude ±0.35 mm; in accordance with IEC 60068-2-6, Test Fc) |
Vibration (Operation) | 57.6 Hz … 150 Hz (Acceleration 5g; in accordance with IEC 60068-2-6, Test Fc) |
UL approval
Identification | UL/C-UL Listed UL 508 |
Identification | UL Recognized UL 2367 |
Standards and Regulations
Standards/specifications | EN 61000-6-2 |
Note | EMC – Immunity for industrial areas |
Standards/specifications | EN 61000-6-3 |
Note | EMC – Emission for residential, business and commercial properties and small operations |
Standards/specifications | EN 60068-2-6 |
Note | Environmental influences – Vibrations (sinusoidal) |
Standards/specifications | EN 60068-2-27 |
Note | Environmental influences – Shocks |
Standards/specifications | EN 60068-2-78 |
Note | Environmental influences – Moisture and heat, constant |
Standards/specifications | EN 50178 |
Note | Equipping power installations with electronic equipment |
Mounting
Mounting Type | DIN rail: 35 mm |
Why Proax for Phoenix Contact CBMC E4 24DC/1-10A IOL?
Proax is an authorized distributor of Phoenix Contact CBMC E4 24DC/1-10A IOL and one of Phoenix Contact's largest distributors in North America. Our highly skilled in-house technical team is ready to assist with any technical needs.
Have a question in mind? to help you get the right product as quickly as possible for your project. We're always here to help!
Short Lead Time
Highly Trained Staff
Live Chat
Technical Support
Local Inventory
60+ Years Experience
Additional Information
Alternate Names | CBMCE424DC110AIOL |
Pack Size | 1 |
Recommended