Proax

Currency
0 Items
proax logo
Cart
Phoenix ContactOfficial Distributor

By Phoenix Contact

SKU
MPN
MACX MCR-EX-SL-IDSI-I
Weight
0.176 kg
This product has been discontinued and replaced with 2908060

MACX MCR-EX-SL-IDSI-I - Output signal conditioner

Ex i output signal conditioner, HART. Isolates and transmits 0/4 - 20 mA signals with intrinsic safety to a load (I/P converters, regulating valves, displays) in the Ex area. Open-circuit detection, SIL 2 in accordance with IEC 61508. Replacement item: 2908060 MACX MCR-EX-IDS-I-I.

  • Power supply possible via DIN rail connector
  • Up to SIL 2 in accordance with EN 61508
  • Installation in zone 2, protection type "n" (EN 60079-15) permitted
  • Line fault detection (LFD)
  • 3-way electrical isolation
  • Output 0/4 mA ... 20 mA, [Ex ia] IIC
  • Plug-in screw or spring-cage connection technology (Push-in technology), with integrated sockets for HART communicators
  • Bidirectional transmission of digital HART communication signals
  • Input: 0/4 mA ... 20 mA
Technical Specifications

Product properties

ApplicationAnalog OUT
No. of channels1
TypeEx i signal conditioners with SIL functional safety

Insulation characteristics

Overvoltage categoryII
Pollution degree2

Electrical properties

Electrical isolation between input and outputyes
Maximum power dissipation for nominal condition< 1.1 W (24 V DC / 20 mA)
Signal transmission behaviorIn = Out
Step response (10-90%)< 140 µs (for 4 mA ... 20 mA step)
Maximum temperature coefficient< 0.01 %/K
Maximum transmission error< 0.1 % (of final value)

Electrical isolation Input/output/power supply

Test voltage1.5 kV AC (50 Hz, 60 s)

Electrical isolation Output/input

Electrical isolation375 V (Peak value in accordance with IEC/EN 60079-11)

Electrical isolation Output/supply

Electrical isolation375 V (Peak value in accordance with IEC/EN 60079-11)

Supply

Supply Voltage Range19.2 V DC ... 30 V DC (24 V DC, -20 % ... +25 %)
Max. current consumption< 46 mA (24 V DC / 20 mA)
Power dissipation< 1.1 W (24 V DC / 20 mA)

Signal: Current

Number of Inputs1
Current Input Signal0 mA ... 20 mA
Current Input Signal4 mA ... 20 mA
Input Impedance> 100 kΩ (If there is a line fault)
Voltage drop5.4 V (20 mA)
Output descriptionCurrent output
Number of Outputs1
Current Output Signal0 mA ... 20 mA (intrinsically safe)
Current Output Signal4 mA ... 20 mA (intrinsically safe)
Load/Output Load Current Output< 800 Ω (20 mA)
Load/Output Load Current Output< 730 Ω (22.5 mA)
Output ripple< 20 mVrms

Connection data

Connection MethodScrew connection
Stripping length7 mm
Screw threadM3
Conductor cross section rigid0.2 mm² ... 2.5 mm²
Conductor cross section flexible0.2 mm² ... 2.5 mm²
Conductor cross section AWG24 ... 14
Tightening torque0.5 Nm ... 0.6 Nm

Safety data

Max. output voltage Uo27.7 V
Max. output current Io92 mA
Max. output power Po633 mW
Safety-related maximum voltage Um253 V AC (125 V DC)
IIC: Max. external inductivity Lo / Max. external capacitance Co2 mH / 85 nF
IIB: Max. external inductivity Lo / Max. external capacitance Co4 mH / 663 nF

Data communication (bypass)

HART FunctionYes
Protocols SupportedHART

Signaling

Status displayGreen LED (supply voltage)

Dimensions

Width12.5 mm
Height112.5 mm
Depth114.5 mm

Material specifications

Colorgray (RAL 7042)
Flammability rating according to UL 94V0 (Housing)
Housing MaterialPA 6.6-FR

Safety data: IEC 61508 - High demand

Safety Integrity Level (SIL)2

Safety data: IEC 61508 - Low demand

Safety Integrity Level (SIL)2

Ambient conditions

Degree of ProtectionIP20 (not assessed by UL)
Ambient Temperature (Operation)-20 °C ... 60 °C (Any mounting position)
Ambient temperature (storage/transport)-40 °C ... 80 °C
Altitude≤ 2000 m
Permissible humidity (operation)10 % ... 95 % (non-condensing)

CE

CertificateCE-compliant
Noteand EN 61326

ATEX

Identification II (1) G [Ex ia Ga] IIC/IIB
Identification II (1) D [Ex ia Da] IIIC
Identification II 3(1) G Ex nA [ia Ga] IIC/IIB T4 Gc
CertificateIECEx BVS 08.0025 X

IECEx

Identification[Ex ia Ga] IIC/IIB
Identification[Ex ia Da] IIIC
IdentificationEx nA [ia Ga] IIC/IIB T4 Gc
CertificateIECEx BVS 08.0025 X

UL, USA/Canada

IdentificationClass I Div 2; IS for Class I, II, III Div 1
Certificate, C.D.-No 83104549

KC-s

Identification[Ex ia] IIC/IIB
Certificate17-KA4BO-0413X

Shipbuilding approval

CertificateDNV GL TAA00000AG

Safety Integrity Level (SIL, IEC 61508)

Identification2

EAC Ex

Identification [Ex ia Ga] IIC
Identification [Ex ia Da] IIIC
CertificateRU C-DE.AB72.B.00093/19

DNV GL data

TemperatureB
HumidityB
VibrationA
EMCB
EnclosureRequired protection according to the Rules shall be provided upon installation on board

EMC data

Noise immunityEN 61000-6-2
NoteWhen being exposed to interference, there may be minimal deviations.
Electromagnetic compatibilityConformance with EMC directive
Noise emissionEN 61000-6-4

Electromagnetic HF field

DesignationElectromagnetic RF field
Standards/regulationsEN 61000-4-3

Mounting

Mounting TypeDIN rail mounting
Accessories

Why Proax for Phoenix Contact 2865405?

Proax is an authorized distributor of Phoenix Contact 2865405 and one of Phoenix Contact's largest distributors in North America. Our highly skilled in-house technical team is ready to assist with any technical needs.

Have a question in mind? to help you get the right product as quickly as possible for your project. We're always here to help!

Short Lead Time
Highly Trained Staff
Live Chat
Technical Support
Local Inventory
60+ Years Experience
Additional Information

Pack Size1
Recommended

Not in stock

Request lead time or order—we'll ensure quick delivery

Phoenix Contact Availability