Proax

Currency
0 Items
proax logo
Cart
Phoenix ContactOfficial Distributor

By Phoenix Contact

SKU
MPN
2708290
Weight
0.247 kg
This product is Not Cancellable/Not Returnable

PSI-MOS-PROFIB/FO 660 E - FO converters

FO converter with integrated optical diagnostics, alarm contact, for PROFIBUS up to 12 Mbps, terminal device with one FO interface (FSMA), 660 nm, for polymer/PCF fiber cable

  • Can be combined with the PSI copper repeater in a modular way using DIN rail connectors
  • Supply voltage and data signals routed through the DIN rail connectors
  • Connections can be plugged in via a COMBICON screw terminal block
  • Automatic data rate detection or fixed data rate setting via DIP switches
  • Redundant power supply
  • High-quality electrical isolation between all interfaces (PROFIBUS // fiber optic ports // power supply // DIN rail connector)
  • Approved for use in zone 2
  • Integrated optical diagnostics for continuous monitoring of FO paths
  • Intrinsically safe fiber optic interface (Ex op is) for direct connection to devices in zone 1
  • Floating switch contact for advance warning of critical FO paths
  • Suitable for all data rates up to 12 Mbps
  • Bit retiming for any cascading depth
  • Shipbuilding approval in accordance with DNV GL
Technical Specifications

Utilization restriction

EMC noteEMC: class A product, see manufacturer's declaration in the download area
CCCex noteUse in potentially explosive areas is not permitted in China.

Product properties

MTTF243 Years (SN 29500 standard, temperature 25°C, operating cycle 21%)
MTTF178 Years (SN 29500 standard, temperature 40°C, operating cycle 34.25%)
MTTF110 Years (SN 29500 standard, temperature 40°C, operating cycle 100%)
MTBF324 Years (Telcordia standard, 25°C temperature, 21% operating cycle (5 days a week, 8 hours a day))
MTBF70 Years (Telcordia standard, 40°C temperature, 34.25% operating cycle (5 days a week, 12 hours a day))

Electrical properties

Electrical isolationVCC // RS-485
Maximum power dissipation for nominal condition2.4 W
Test voltage data interface/power supply1.5 kVrms (50 Hz, 1 min.)

Supply

Supply Voltage Range18 V DC ... 30 V DC (via pluggable COMBICON screw terminal block)
Nominal Supply Voltage24 V DC (in acc. with UL)
Typical current consumption100 mA (24 V DC)
Max. current consumption130 mA
Max. current consumption≤ 2 A (For operation in a joining station, via the DIN rail connector)

Switching

Output nameRelay output
Output descriptionAlarm output
Number of Outputs1
Maximum Switching Voltage60 V DC (Resistive Load, General Load)
Maximum Switching Voltage30 V AC (Resistive load)
Maximum Switching Voltage42 V AC (peak, resistive load)
Limiting Continuous Current0.46 A

Supply

Connection MethodCOMBICON plug-in screw terminal block
Stripping length7.00 mm
Tightening torque0.56 Nm ... 0.79 Nm

Interfaces

Bit distortion, input± 35 % (permitted)
Bit distortion, output< 6.25 %
Bit delay< 1 bit (DIP 7 = OFF, standard operation)
Bit delay11 bit (DIP 7 = ON, redundancy operation)
SignalPROFIBUS

Data: optical FO

No. of channels1
Transmit capacity, minimum-3 dBm (980/1000 µm)
Transmit capacity, minimum-15.4 dBm (200/230 µm)
Transmission length incl. 3 dB system reserve70 m (F-P 980/1000 230 dB/km with quick mounting connector)
Transmission length incl. 3 dB system reserve400 m (F-K 200/230 10 dB/km with quick mounting connector)
Transmission protocolProtocol-transparent to the RS-485 interface
Connection MethodF-SMA
Wavelength660 nm
Minimum receiver sensitivity-30 dBm
Maximum receiver sensitivity-3 dBm (980/1000 µm)
Transmission mediumPolymer fiber
Transmission mediumPCF fiber

Data: PROFIBUS acc. to IEC 61158, RS-485 2-wire, half duplex, automatic control

Serial transmission speed≤ 12 Mbps
Connection MethodD-SUB-9 female connector
Transmission length≤ 1200 m (depending on the data rate, with shielded, twisted pair data cable)
Single conductor/terminal point, rigid0.2 mm² ... 2.5 mm²
Single-wire/terminal point, flexible0.2 mm² ... 2.5 mm²
Max. AWG conductor cross section, flexible14
Min. AWG conductor cross section, flexible24
Single-wire/terminal point, rigid AWG max.14
Single-wire/terminal point, rigid AWG min.24
Transmission mediumCopper
File format/codingUART (11 Bit, NRZ)
Data direction switchingAutomatic control
Output nominal voltage5 V ±0.25 (50 mA)

Dimensions

Width35 mm
Height99 mm
Depth106 mm

Material specifications

Color (Housing)green (RAL 6021)
Material (Housing)PA 6.6-FR

FO cable

Fiber types980/1000 µm
Fiber types200/230 µm
Fiber typesPolymer fiber
Fiber typesPCF fiber

Ambient conditions

Degree of ProtectionIP20
Ambient Temperature (Operation)-20 °C ... 60 °C
Ambient temperature (storage/transport)-40 °C ... 85 °C
Altitude≤ 5000 m (For restrictions, see the manufacturer's declaration for altitude operation)
Altitude≤ 2000 m (Hazardous locations)
Permissible humidity (operation)30 % ... 95 % (non-condensing)

CE

CertificateCE-compliant

ATEX

Identification II 3 G Ex nA nC IIC T4 Gc X
NotePlease follow the special installation instructions in the documentation!

ATEX, FO interface

Identification II (2) G [Ex op is Gb] IIC
Identification II (2) D [Ex op is Db] IIIC
CertificatePTB 06 ATEX 2042 U
NotePlease follow the special installation instructions in the documentation!

UL, USA/Canada

IdentificationClass I, Zone 2, AEx nc IIC T5
IdentificationClass I, Zone 2, Ex nC nL IIC T5 X
IdentificationClass I, Div. 2, Groups A, B, C, D

PROFIBUS interoperability

NoteTested by independent PNO test laboratory (PN059-485-01)

ABB certification

IdentificationIndustrialIT enabled
NoteThis certification is a trademark of ABB.

Corrosive gas test

IdentificationISA-S71.04-1985 G3 Harsh Group A

Shipbuilding

IdentificationDNV GL

DNV GL data

TemperatureB
HumidityA
VibrationA
EMCB
EnclosureRequired protection according to the Rules shall be provided upon installation on board

EMC data

Noise immunityEN 61000-6-2:2005
Electromagnetic compatibilityConformance with EMC Directive 2014/30/EU
Noise emissionEN 55011

Electrostatic discharge

Standards/regulationsEN 61000-4-2
Contact discharge± 6 kV
Discharge in air± 8 kV
CommentsCriterion B

Electromagnetic HF field

Standards/regulationsEN 61000-4-3
Field intensity10 V/m
CommentsCriterion A

Fast transients (burst)

Standards/regulationsEN 61000-4-4
Input± 2 kV
Signal± 2 kV
CommentsCriterion B

Surge current load (surge)

Standards/regulationsEN 61000-4-5
Input± 0.5 kV
Signal± 1 kV
CommentsCriterion B

Conducted interference

Standards/regulationsEN 61000-4-6
CommentsCriterion A
Voltage10 V

Emitted interference

Standards/regulationsEN 55011
CommentsClass A, industrial applications

Criteria

Criterion ANormal operating behavior within the specified limits.
Criterion BTemporary impairment to operational behavior that is corrected by the device itself.

Standards and Regulations

Free from substances that could impair the application of coatingin accordance with VW-AUDI-Seat central standard P-VW 3.10.7 57 65 0

Air clearances and creepage distances

Standards/regulationsDIN EN 60664-1
Standards/regulationsVDE 0110-1
Standards/regulationsDIN EN 50178
Standards/regulationsEN 60950

Mounting

Mounting TypeDIN rail mounting
Accessories

Why Proax for Phoenix Contact PSI-MOS-PROFIB/FO 660 E?

Proax is an authorized distributor of Phoenix Contact PSI-MOS-PROFIB/FO 660 E and one of Phoenix Contact's largest distributors in North America. Our highly skilled in-house technical team is ready to assist with any technical needs.

Have a question in mind? to help you get the right product as quickly as possible for your project. We're always here to help!

Short Lead Time
Highly Trained Staff
Live Chat
Technical Support
Local Inventory
60+ Years Experience
Additional Information

Alternate NamesPSIMOSPROFIBFO660E
Pack Size1
Recommended

Available for order