Official Distributor
SKU
MPN
2708054
Weight
0.197 kg
This product is Not Cancellable/Not Returnable
Series PSI-MOS-DNET-CAN-FO
PSI-MOS-DNET CAN/FO 660/BM - FO converters
FO converter with integrated optical diagnostics, for DeviceNet™, CAN, CANopen® up to 800 kbps, basic module, interfaces: 1 x CAN, 1 x alarm, 1 x FO (FSMA), 660 nm, for polymer/PCF fiberglass cable
- Supply voltage routed through via DIN rail connectors
- Connections can be plugged in via a COMBICON screw terminal block
- Approved for use in zone 2
- Floating switch contact for advance warning of critical FO paths
- Integrated optical diagnostics for continuous monitoring of FO paths
- Intrinsically safe fiber optic interface (Ex op is) for direct connection to devices in zone 1
- Data rates of up to 800 kbps, set via DIP switches
Technical Specifications
Utilization restriction
EMC note | EMC: class A product, see manufacturer's declaration in the download area |
CCCex note | Use in potentially explosive areas is not permitted in China. |
Product properties
Application | Base module |
MTBF | 409 Years (Telcordia standard, 25°C temperature, 21% operating cycle (5 days a week, 8 hours a day)) |
MTBF | 82 Years (Telcordia standard, 40°C temperature, 34.25% operating cycle (5 days a week, 12 hours a day)) |
Electrical properties
Electrical isolation | VCC // CAN |
Maximum power dissipation for nominal condition | 2 W |
Test voltage data interface/power supply | 1.5 kVrms (50 Hz, 1 min.) |
Supply
Supply Voltage Range | 10 V DC ... 30 V DC (via pluggable COMBICON screw terminal block) |
Nominal Supply Voltage | 24 V DC (in acc. with UL) |
Typical current consumption | 100 mA (24 V DC) |
Max. current consumption | 100 mA |
Switching
Output name | Relay output |
Output description | Alarm output |
Number of Outputs | 1 |
Maximum Switching Voltage | 60 V DC |
Maximum Switching Voltage | 42 V AC |
Limiting Continuous Current | 0.46 A |
Supply
Connection Method | Pluggable COMBICON screw terminal block through basic module |
Tightening torque | 0.56 Nm ... 0.79 Nm |
Interfaces
Bit distortion, input | ± 35 % (permitted) |
Bit distortion, output | < 6.25 % |
Signal | CAN |
Signal | CANopen® |
Signal | DeviceNet™ |
Data: optical FO
Transmit capacity, minimum | -6.2 dBm (980/1000 µm) |
Transmit capacity, minimum | -16.9 dBm (200/230 µm) |
Transmission length incl. 3 dB system reserve | 100 m (F-P 980/1000 230 dB/km with quick mounting connector) |
Transmission length incl. 3 dB system reserve | 800 m (F-K 200/230 10 dB/km with quick mounting connector) |
Connection Method | F-SMA |
Wavelength | 660 nm |
Minimum receiver sensitivity | -30.2 dBm |
Transmission medium | Polymer fiber |
Transmission medium | PCF fiber |
Data: CAN interface, in accordance with ISO/IS 11898 for DeviceNet™, CAN, CANopen®
Serial transmission speed | ≤ 800 kbps |
Connection Method | Pluggable screw connection |
Transmission length | ≤ 5000 m (Dependent on the data rate and the protocol used) |
Termination resistor | 120 Ω (Can be connected) |
Transmission medium | Copper |
File format/coding | Bit stuffing, NRZ |
Dimensions
Width | 22.5 mm |
Height | 99 mm |
Depth | 114.5 mm |
Material specifications
Color (Housing) | green (RAL 6021) |
Material (Housing) | PA 6.6-FR |
FO cable
Fiber types | 200/230 µm |
Fiber types | 980/1000 µm |
Fiber types | Polymer fiber |
Fiber types | PCF fiber |
Ambient conditions
Degree of Protection | IP20 |
Ambient Temperature (Operation) | -20 °C ... 60 °C |
Ambient temperature (storage/transport) | -40 °C ... 85 °C |
Altitude | ≤ 5000 m (For restrictions, see the manufacturer's declaration for altitude operation) |
Permissible humidity (operation) | 30 % ... 95 % (non-condensing) |
CE
Certificate | CE-compliant |
ATEX
Identification | II 3 G Ex nA nC IIC T4 Gc X |
Note | Please follow the special installation instructions in the documentation! |
ATEX, FO interface
Identification | II (2) G [Ex op is Gb] IIC |
Identification | II (2) D [Ex op is Db] IIIC |
Certificate | PTB 06 ATEX 2042 U |
Note | Please follow the special installation instructions in the documentation! |
UL, USA/Canada
Identification | Class I, Zone 2, AEx nc IIC T5 |
Identification | Class I, Div. 2, Groups A, B, C, D |
Corrosive gas test
Identification | ISA-S71.04-1985 G3 Harsh Group A |
EMC data
Noise immunity | EN 61000-6-2:2005 |
Electromagnetic compatibility | Conformance with EMC Directive 2014/30/EU |
Noise emission | EN 55011 |
Electrostatic discharge
Standards/regulations | EN 61000-4-2 |
Contact discharge | ± 6 kV |
Discharge in air | ± 8 kV |
Comments | Criterion B |
Electromagnetic HF field
Standards/regulations | EN 61000-4-3 |
Field intensity | 10 V/m |
Comments | Criterion A |
Fast transients (burst)
Standards/regulations | EN 61000-4-4 |
Input | 2 kV (5 kHz) |
Signal | 2 kV (5 kHz) |
Comments | Criterion B |
Surge current load (surge)
Input | 0.5 kV (42 Ω) |
Signal | 1 kV (2 Ω) |
Comments | Criterion B |
Conducted interference
Standards/regulations | EN 61000-4-6 |
Comments | Criterion A |
Voltage | 10 V |
Emitted interference
Standards/regulations | EN 55011 |
Comments | Class A, industrial applications |
Criteria
Criterion A | Normal operating behavior within the specified limits. |
Criterion B | Temporary impairment to operational behavior that is corrected by the device itself. |
Mounting
Mounting Type | DIN rail mounting |
Accessories
Why Proax for Phoenix Contact PSI-MOS-DNET CAN/FO 660/BM?
Proax is an authorized distributor of Phoenix Contact PSI-MOS-DNET CAN/FO 660/BM and one of Phoenix Contact's largest distributors in North America. Our highly skilled in-house technical team is ready to assist with any technical needs.
Have a question in mind? to help you get the right product as quickly as possible for your project. We're always here to help!
Short Lead Time
Highly Trained Staff
Live Chat
Technical Support
Local Inventory
60+ Years Experience
Additional Information
Alternate Names | PSIMOSDNETCANFO660BM |