Series PSI-MOS-DNET-CAN-FO
PSI-MOS-DNET CAN/FO 660/EM - FO converters
FO converter with integrated optical diagnosis, for DeviceNet™, CAN, CANopen® to 800 kbps, extension/redundancy module, interfaces: 1x FO (FSMA), 660 nm, for polymer/PCF fiber cable
- Data rates of up to 800 kbps, set via DIP switches
- Approved for use in zone 2
- Intrinsically safe fiber optic interface (Ex op is) for direct connection to devices in zone 1
Technical Specifications
Utilization restriction
| CCCex note | Use in potentially explosive areas is not permitted in China. | 
Product properties
| Application | Extension module | 
| MTBF | 456 Years (Telcordia standard, 25°C temperature, 21% operating cycle (5 days a week, 8 hours a day)) | 
| MTBF | 89 Years (Telcordia standard, 40°C temperature, 34.25% operating cycle (5 days a week, 12 hours a day)) | 
Electrical properties
| Electrical isolation | VCC // CAN | 
| Maximum power dissipation for nominal condition | 2 W | 
| Test voltage data interface/power supply | 1.5 kVrms (50 Hz, 1 min.) | 
Supply
| Supply Voltage Range | 10 V DC ... 30 V DC | 
| Nominal Supply Voltage | 24 V DC (in acc. with UL) | 
| Typical current consumption | 100 mA (24 V DC) | 
| Max. current consumption | 100 mA | 
| Connection Method | Pluggable COMBICON screw terminal block through basic module | 
| Tightening torque | 0.56 Nm ... 0.79 Nm | 
Interfaces
| Bit distortion, input | ± 35 % (permitted) | 
| Bit distortion, output | < 6.25 % | 
| Signal | CAN | 
| Signal | CANopen® | 
| Signal | DeviceNet™ | 
Data: optical FO
| Transmit capacity, minimum | -6.2 dBm (980/1000 µm) | 
| Transmit capacity, minimum | -16.9 dBm (200/230 µm) | 
| Transmission length incl. 3 dB system reserve | 100 m (F-P 980/1000 230 dB/km with quick mounting connector) | 
| Transmission length incl. 3 dB system reserve | 800 m (F-K 200/230 10 dB/km with quick mounting connector) | 
| Connection Method | F-SMA | 
| Wavelength | 660 nm | 
| Minimum receiver sensitivity | -30.2 dBm | 
| Transmission medium | Polymer fiber | 
| Transmission medium | PCF fiber | 
Data: CAN interface, in accordance with ISO/IS 11898 for DeviceNet™, CAN, CANopen®
| Serial transmission speed | ≤ 800 kbps | 
| Connection Method | Pluggable screw connection | 
| Transmission length | ≤ 5000 m (Dependent on the data rate and the protocol used) | 
| Transmission medium | Copper | 
| File format/coding | Bit stuffing, NRZ | 
Dimensions
| Width | 22.5 mm | 
| Height | 99 mm | 
| Depth | 114.5 mm | 
Material specifications
| Color (Housing) | green (RAL 6021) | 
| Material (Housing) | PA 6.6-FR | 
FO cable
| Fiber types | 200/230 µm | 
| Fiber types | 980/1000 µm | 
| Fiber types | Polymer fiber | 
| Fiber types | PCF fiber | 
Ambient conditions
| Degree of Protection | IP20 | 
| Ambient Temperature (Operation) | -20 °C ... 60 °C | 
| Ambient temperature (storage/transport) | -40 °C ... 85 °C | 
| Altitude | ≤ 5000 m (For restrictions, see the manufacturer's declaration for altitude operation) | 
| Permissible humidity (operation) | 30 % ... 95 % (non-condensing) | 
CE
| Certificate | CE-compliant | 
ATEX
| Identification |  II 3 G Ex nA nC IIC T4 Gc X | 
| Note | Please follow the special installation instructions in the documentation! | 
ATEX, FO interface
| Identification |  II (2) G [Ex op is Gb] IIC | 
| Identification |  II (2) D [Ex op is Db] IIIC | 
| Certificate | PTB 06 ATEX 2042 U | 
| Note | Please follow the special installation instructions in the documentation! | 
UL, USA/Canada
| Identification | Class I, Zone 2, AEx nc IIC T5 | 
| Identification | Class I, Div. 2, Groups A, B, C, D | 
Corrosive gas test
| Identification | ISA-S71.04-1985 G3 Harsh Group A | 
EMC data
| Noise immunity | EN 61000-6-2:2005 | 
| Electromagnetic compatibility | Conformance with EMC Directive 2014/30/EU | 
| Noise emission | EN 55011 | 
Electrostatic discharge
| Standards/regulations | EN 61000-4-2 | 
| Contact discharge | ± 6 kV | 
| Discharge in air | ± 8 kV | 
| Comments | Criterion B | 
Electromagnetic HF field
| Standards/regulations | EN 61000-4-3 | 
| Field intensity | 10 V/m | 
| Comments | Criterion A | 
Fast transients (burst)
| Standards/regulations | EN 61000-4-4 | 
| Input | 2 kV (5 kHz) | 
| Signal | 2 kV (5 kHz) | 
| Comments | Criterion B | 
Surge current load (surge)
| Input | 0.5 kV (42 Ω) | 
| Signal | 1 kV (2 Ω) | 
| Comments | Criterion B | 
Conducted interference
| Standards/regulations | EN 61000-4-6 | 
| Comments | Criterion A | 
| Voltage | 10 V | 
Emitted interference
| Standards/regulations | EN 55011 | 
| Comments | Class A, industrial applications | 
Criteria
| Criterion A | Normal operating behavior within the specified limits. | 
| Criterion B | Temporary impairment to operational behavior that is corrected by the device itself. | 
Mounting
| Mounting Type | DIN rail mounting | 
Accessories
Why Proax for Phoenix Contact 2708067?
Proax is an authorized distributor of Phoenix Contact 2708067 and one of Phoenix Contact's largest distributors in North America. Our highly skilled in-house technical team is ready to assist with any technical needs.
Have a question in mind? to help you get the right product as quickly as possible for your project. We're always here to help!
Short Lead Time
Highly Trained Staff
Live Chat
Technical Support
Local Inventory
60+ Years Experience
Additional Information
| Pack Size | 1 | 
Recommended