Official Distributor
SKU
MPN
PSI-MOS-CNET/FO 850 E
Weight
0.249 kg
This product is Not Cancellable/Not Returnable
Series PSI-MOS-CNET-FO
PSI-MOS-CNET/FO 850 E - FO converters
Fiber optic converter with integrated optical diagnostics, for ControlNet, 5 Mbps data rate, termination device, interfaces: 1 x CNET, 1 x Alarm, 1 x FO (B-FOC), 850 nm, for PCF/fiberglass (multi-mode)
- Approved for use in zone 2
- Intrinsically safe fiber optic interface (Ex op is) for direct connection to devices in zone 1
- Floating switch contact for advance warning of critical FO paths
- Integrated optical diagnostics for continuous monitoring of FO paths
- Connections can be plugged in via a COMBICON screw terminal block
- Supply voltage and data signals routed through the DIN rail connectors
- Can be combined with the PSI copper repeater in a modular way using DIN rail connectors
- Redundant power supply possible by means of optional system power supply unit
- High-quality electrical isolation between all interfaces (ControlNet // fiber optic ports // power supply // DIN rail connector)
Technical Specifications
Utilization restriction
EMC note | EMC: class A product, see manufacturer's declaration in the download area |
Product properties
MTTF | 985 Years (SN 29500 standard, temperature 25°C, operating cycle 21%) |
MTTF | 418 Years (SN 29500 standard, temperature 40°C, operating cycle 34.25%) |
MTTF | 173 Years (SN 29500 standard, temperature 40°C, operating cycle 100%) |
MTBF | 297 Years (Telcordia standard, 25°C temperature, 21% operating cycle (5 days a week, 8 hours a day)) |
MTBF | 47 Years (Telcordia standard, 40°C temperature, 34.25% operating cycle (5 days a week, 12 hours a day)) |
Electrical properties
Electrical isolation | VCC // ControlNet™ |
Maximum power dissipation for nominal condition | 2.4 W |
Test voltage data interface/power supply | 1.5 kVrms (50 Hz, 1 min.) |
Supply
Supply Voltage Range | 18 V DC ... 30 V DC (via pluggable COMBICON screw terminal block) |
Nominal Supply Voltage | 24 V DC |
Typical current consumption | 100 mA (24 V DC) |
Max. current consumption | 110 mA |
Max. current consumption | ≤ 2 A (For operation in a joining station, via the DIN rail connector) |
Function
Status and diagnostic indicators | Port A (module status indicator), FO signal (fiber optic signal quality), ERR (broken fiber, fiber optic) |
Switching
Output name | Relay output |
Number of Outputs | 1 |
Contact switching type | N/O contact |
Minimum Switching Voltage | 18 V DC |
Maximum Switching Voltage | 30 V DC |
Limiting Continuous Current | 500 mA |
Supply
Tightening torque | 0.56 Nm ... 0.79 Nm |
Interfaces
Bit distortion, input | ± 35 % |
Bit distortion, output | < 6.25 % |
Signal | ControlNet™ |
Data: optical FO
Transmit capacity, minimum | -17.9 dBm (50/125 µm) |
Transmit capacity, minimum | -14.1 dBm (62,5/125 µm) |
Transmit capacity, minimum | -5.1 dBm (200/230 µm) |
Transmission length incl. 3 dB system reserve | 1200 m (F-K 200/230 8 dB/km with quick mounting connector) |
Transmission length incl. 3 dB system reserve | 3100 m (with F-G 50/125 2.5 dB/km) |
Transmission length incl. 3 dB system reserve | 3000 m (with F-G 62,5/125 3.0 dB/km) |
Transmission protocol | Protocol transparent for ControlNet™ interface |
Connection Method | B-FOC (ST®) |
Wavelength | 850 nm |
Minimum receiver sensitivity | -32.5 dBm (50/125 µm) |
Minimum receiver sensitivity | -32.5 dBm (62,5/125 µm) |
Minimum receiver sensitivity | -32.1 dBm (200/230 µm) |
Transmission medium | PCF fiber |
Transmission medium | Multi-mode fiberglass |
Data: ControlNet interface, in accordance with EN 50170
Serial transmission speed | 5 Mbps |
Connection Method | BNC 75 Ω |
Transmission length | ≤ 1000 m |
Conductor cross section flexible max. | 2.5 mm² |
Conductor cross section flexible min. | 0.2 mm² |
Conductor cross section, rigid max. | 2.5 mm² |
Conductor cross section, rigid min. | 0.2 mm² |
Conductor cross section AWG max. | 14 |
Conductor cross section AWG min. | 24 |
Transmission medium | Copper |
File format/coding | Serial asynchronous UART/NRZ |
Dimensions
Width | 35 mm |
Height | 105 mm |
Depth | 117 mm |
Material specifications
Color (Housing) | green (RAL 6021) |
Material (Housing) | PA 6.6-FR |
FO cable
Fiber types | 200/230 µm |
Fiber types | 50/125 µm |
Fiber types | 62.5/125 µm |
Fiber types | PCF fiber |
Fiber types | Fiberglass |
Ambient conditions
Degree of Protection | IP20 |
Ambient Temperature (Operation) | -20 °C ... 60 °C |
Ambient temperature (storage/transport) | -40 °C ... 85 °C |
Altitude | ≤ 5000 m (For restrictions, see the manufacturer's declaration for altitude operation) |
Permissible humidity (operation) | 30 % ... 95 % (non-condensing) |
CE
Certificate | CE-compliant |
ATEX
Identification | II 3 G Ex nA IIC T4 Gc X |
Note | Please follow the special installation instructions in the documentation! |
Identification | II (2) G [Ex op is Gb] IIC |
Identification | II (2) D [Ex op is Db] IIIC |
Certificate | PTB 06 ATEX 2042 U |
UL, USA/Canada
Identification | 508 Listed |
EMC data
Noise immunity | EN 61000-6-2 |
Electromagnetic compatibility | Conformance with EMC Directive 2014/30/EU |
Noise emission | EN 55011 |
Electrostatic discharge
Standards/regulations | EN 61000-4-2 |
Contact discharge | ± 6 kV |
Discharge in air | ± 8 kV |
Comments | Criterion B |
Electromagnetic HF field
Standards/regulations | EN 61000-4-3 |
Field intensity | 10 V/m |
Comments | Criterion A |
Fast transients (burst)
Standards/regulations | EN 61000-4-4 |
Input | ± 2 kV |
Signal | ± 2 kV |
Comments | Criterion B |
Surge current load (surge)
Standards/regulations | EN 61000-4-5 |
Input | ± 0.5 kV |
Signal | ± 1 kV |
Comments | Criterion B |
Conducted interference
Standards/regulations | EN 61000-4-6 |
Comments | Criterion A |
Voltage | 10 V |
Emitted interference
Standards/regulations | EN 55011 |
Comments | Class A, industrial applications |
Criteria
Criterion A | Normal operating behavior within the specified limits. |
Criterion B | Temporary impairment to operational behavior that is corrected by the device itself. |
Standards and Regulations
Free from substances that could impair the application of coating | in accordance with VW-AUDI-Seat central standard P-VW 3.10.7 57 65 0 |
Mounting
Mounting Type | DIN rail mounting |
Why Proax for Phoenix Contact 2313711?
Proax is an authorized distributor of Phoenix Contact 2313711 and one of Phoenix Contact's largest distributors in North America. Our highly skilled in-house technical team is ready to assist with any technical needs.
Have a question in mind? to help you get the right product as quickly as possible for your project. We're always here to help!
Short Lead Time
Highly Trained Staff
Live Chat
Technical Support
Local Inventory
60+ Years Experience
Additional Information
Pack Size | 1 |
Recommended