SKU
MPN
AXL F CNT2 INC2 1F
Weight
0.254 kg
This product is Not Cancellable/Not Returnable
Series AXL-F-CNT2

AXL F CNT2 INC2 1F - Function module

Axioline F, Function module, Counter inputs: 2, Incremental encoder inputs: 2, Symmetrical and asymmetrical encoders, Digital inputs: 8, 24 V DC, Digital outputs: 2, 24 V DC, transmission speed in the local bus: 100 Mbps, degree of protection: IP20, including bus base module and Axioline F connectors

  • 2 channels, selectable for each channel: counter function or position detection using incremental encoder
  • Maximum input frequency: 300 kHz (one channel wired) or 100 kHz (both channels wired)
  • 32-bit counter (up and down)
  • Output control according to two limit values
  • Counter: counting (source) is controlled via a control input (gate)
  • Counter: single or periodic counting
  • Incremental encoder acquisition: Acquisition of digital signals from symmetrical and asymmetrical incremental encoders
  • Incremental encoder acquisition: evaluation of linear or rotary axes
  • Device rating plate stored
Technical Specifications

Dimensions

Width53.6 mm
Height126.1 mm
Depth54 mm
Note on dimensionsThe depth applies when a TH 35-7.5 DIN rail is used (in accordance with EN 60715).

Axioline F local bus

Number of interfaces2
Connection MethodBus base module
Transmission Speed100 Mbps

Module

ID code (hex)none
Input address area28 Byte
Output address area28 Byte
Required parameter data 115 Byte
Required configuration data 7 Byte

Digital:

Input nameDigital inputs
Description of the inputEN 61131-2, type 3
Number of Inputs8 (CNT: G1, G2, Dir1, Dir2; INC: Ref1, Ref2, L1, L2)
Connection MethodPush-in connection
Connection technology1-conductor (optional 2, 3-conductor)
Input voltage range "0" signal-3 V DC ... 5 V DC
Input voltage range "1" signal11 V DC ... 30 V DC
Nominal input voltage UIN24 V DC
Nominal input current at UIN2.5 mA (per channel)

Encoder

Number of Inputs2 (A1, /A1, B1, /B1, Z1, /Z1; A2, /A2, B2, /B2, Z2, /Z2)
Input nameIncremental encoder inputs
Encoder signalsSymmetrical and asymmetrical encoders
Cable Lengthmax. 30 m

Counter:

Input nameCounter inputs
Description of the inputEN 61131-2, type 3
Connection MethodPush-in connection
Number of Inputs2 (S1, S2)
Input Voltage24 V DC
Input voltage range "0" signal-3 V DC ... 5 V DC
Input voltage range "1" signal11 V DC ... 30 V DC
Input Frequencymax. 300 kHz (1 channel wired)
Input Frequencymax. 100 kHz (more than one channel wired or Z signal monitoring via the firmware)
Input Current2.5 mA (per channel)
Resolution32 bits
Permissible cable lengthmax. 30 m

Digital:

Output nameDigital outputs
Connection MethodPush-in connection
Connection technology1-conductor
Number of Outputs2 (Out1, Out2)
Protective circuitShort-circuit protection
Protective circuitOverload protection
Output Voltage24 V DC
Maximum Output Current per channel500 mA
Nominal Output Voltage24 V DC
Nominal load, inductivemax. 12 VA (1.2 H, 48 Ω, with nominal voltage)
Nominal load, lampmax. 12 W (at nominal voltage)
Nominal load, ohmicmax. 12 W (48 Ω, with nominal voltage)

Product properties

Product familyAxioline F
Typeblock modular
Mounting Positionany (no temperature derating)
Scope of deliveryincluding bus base module and Axioline F connectors

Insulation characteristics

Overvoltage categoryII (IEC 60664-1, EN 60664-1)
Pollution degree2 (IEC 60664-1, EN 60664-1)

Electrical properties

Maximum power dissipation for nominal condition0.6 W

Encoder

Number2 (UE1, UE2)
Nominal Output Voltage5 V DC
Voltage range5 V DC ... 5.5 V DC
Current carrying capacitymax. 250 mA
Protective circuitShort-circuit protection; electronic
Number2 (US1, US2)
Nominal Output Voltage24 V DC
Voltage range19.2 V DC ... 30 V DC
Current carrying capacitytyp. 500 mA
Protective circuitShort-circuit protection; electronic
Numbermax. 2 (A, /A, B, /B, (Z, /Z))
DesignationSymmetrical incremental encoders
Type of connection of signalsPush-in connection
Encoder supply voltage5 V DC
Encoder supply voltage24 V DC
Signal voltage levelDifferential signal (signal – inverted signal) ±0.5 V, minimum; ±6 V, maximum
Common mode voltage range signal - ground-10 V ... 13.2 V
Input Frequencymax. 300 kHz (1 channel wired)
Input Frequencymax. 100 kHz (more than one channel wired or Z signal monitoring via the firmware)
Numbermax. 2 (A, B, (Z))
DesignationAsymmetrical incremental encoder
Type of connection of signalsPush-in connection
Signal voltage levelLow ≤ 2.5 V, high ≥ 3.5 V (up to 27 V, maximum)
Input Frequencymax. 300 kHz (1 channel wired)
Input Frequencymax. 100 kHz (more than one channel wired or Z signal monitoring via the firmware)

Potentials: Axioline F local bus supply (UBus)

Supply Voltage5 V DC (via bus base module)
Current drawmax. 120 mA
Current drawtyp. 100 mA
Power consumptionmax. 0.6 W
Power consumptiontyp. 0.5 W

Potentials: Feed-in of supply voltage (UI)

Supply Voltage24 V DC
Supply Voltage Range19.2 V DC ... 30 V DC (including all tolerances, including ripple)
Current drawmax. 2.5 A (dependent on the encoder or sensor type used and the load on the digital output.)
Power consumptionmax. 60 W (of which 1.6 W internal losses)
Protective circuitSurge protection; electronic (35 V, 0.5 s)
Protective circuitReverse polarity protection; parallel diode; with external 5 A fuse (only for commissioning)

Electrical isolation/isolation of the voltage ranges

Test voltage: 5 V supply of the local bus (UBus) / 24 V supply (I/Os)500 V AC, 50 Hz, 1 min.
Test voltage: 5 V supply of the local bus (UBus) / functional ground500 V AC, 50 Hz, 1 min.
Test voltage: 24 V supply (I/O) / functional ground500 V AC, 50 Hz, 1 min.

Connection technology

Connection nameAxioline F connector
Note on the connection methodPlease observe the information provided on conductor cross sections in the “Axioline F: system and installation” user manual.

Conductor connection

Connection MethodPush-in connection
Conductor cross section rigid0.2 mm² ... 1.5 mm²
Conductor cross section flexible0.2 mm² ... 1.5 mm²
Conductor cross section AWG24 ... 16
Stripping length8 mm

Axioline F connector

Connection MethodPush-in connection
Note on the connection methodPlease observe the information provided on conductor cross sections in the “Axioline F: system and installation” user manual.
Conductor cross section, rigid0.2 mm² ... 1.5 mm²
Conductor cross section, flexible0.2 mm² ... 1.5 mm²
Conductor cross section AWG24 ... 16
Stripping length8 mm

Ambient conditions

Ambient Temperature (Operation)-25 °C ... 60 °C
Degree of ProtectionIP20
Air pressure (operation)70 kPa ... 106 kPa (up to 3000 m above sea level)
Air pressure (storage/transport)70 kPa ... 106 kPa (up to 3000 m above sea level)
Ambient temperature (storage/transport)-40 °C ... 85 °C
Permissible humidity (operation)5 % ... 95 % (non-condensing)
Permissible humidity (storage/transport)5 % ... 95 % (non-condensing)

Standards and Regulations

Protection classIII (IEC 61140, EN 61140, VDE 0140-1)

Mounting

Mounting TypeDIN rail mounting
Mounting Positionany (no temperature derating)
Accessories

Why Proax for Phoenix Contact 2688093?

Proax is an authorized distributor of Phoenix Contact 2688093 and one of Phoenix Contact's largest distributors in North America. Our highly skilled in-house technical team is ready to assist with any technical needs.

Have a question in mind? to help you get the right product as quickly as possible for your project. We're always here to help!

Short Lead Time
Highly Trained Staff
Live Chat
Technical Support
Local Inventory
60+ Years Experience
Additional Information

Pack Size1
Recommended

Not in stock

Request lead time or order—we'll ensure quick delivery

Phoenix Contact Availability