AXL F DO16 FLK 1H - Digital module

Axioline F, Digital output module, Digital outputs: 16, 24 V DC, 500 mA, connection technology: FLK connector (20-pos.), transmission speed in the local bus: 100 Mbps, degree of protection: IP20, including bus base module and Axioline F connector

  • 16 digital outputs
  • 24 V DC, 500 mA
  • 1 FLK connection, 20-pos.
  • Minimum update time of < 100 μs
  • Device rating plate stored
  • Diagnostic and status indicators
Technical Specifications

Dimensions

Width35 mm
Height126.1 mm
Depth54 mm
Note on dimensionsThe depth applies when a TH 35-7.5 DIN rail is used (in accordance with EN 60715).

Utilization restriction

EMC noteEMC: class A product, see manufacturer's declaration in the download area

Axioline F local bus

Number of interfaces2
Connection MethodBus base module
Transmission Speed100 Mbps

Module

Input address area0 Byte
Output address area2 Byte
Required parameter data 1 Byte
Required configuration data 6 Byte

Digital:

Output nameDigital outputs
Connection MethodFLK20 pin strip
Connection technologyFLK connector (20-pos.)
Number of Outputs16
Protective circuitShort-circuit protection, overload protection of the outputs; electronic
Output Voltage24 V
Limitation of the voltage induced on circuit interruption-25.8 V ... -15 V
Maximum Output Current per module8 A (provide external protection)
Nominal Output Voltage24 V DC
Load min.10 kΩ
Output voltage when switched offmax. 1 V
Output current when switched offmax. 300 µA
Nominal load, inductivemax. 12 VA (1.2 H, 48 Ω, with nominal voltage)
Nominal load, lampmax. 12 W (at nominal voltage)
Nominal load, ohmicmax. 12 W (48 Ω, with nominal voltage)
Switching frequencymax. 10000 per second (with at least 50 mA load current)
Switching frequencymax. 1 per second (with inductive load)
Switching frequencymax. 16 per second (with nominal lamp load)
Reverse voltage resistance to short pulseslimited protection up to 0.5 A for 1 s
Behavior with overloadShutdown with automatic restart
Behavior with inductive overloadOutput can be destroyed
Signal delaymax. 100 µs (when switched on)
Signal delaymax. 100 µs (when switched off, with at least 50 mA load current)
Overcurrent shut-downas of 0.7 A
Output current with ground connection interrupt when switched off< 1 mA

Product properties

Product familyAxioline F
Typeblock modular
Mounting Positionany (no temperature derating)
Scope of deliveryincluding bus base module and Axioline F connector
Diagnostics messagesI/O supply failure can be parameterized via PDI object FF8Fhex
Diagnostics messagesShort-circuit or overload of the digital outputs yes

Insulation characteristics

Overvoltage categoryII (IEC 60664-1, EN 60664-1)
Pollution degree2 (IEC 60664-1, EN 60664-1)

Electrical properties

Maximum power dissipation for nominal condition1.16 W

Potentials: Axioline F local bus supply (UBus)

Supply Voltage5 V DC (via bus base module)
Current drawmax. 120 mA
Power consumptionmax. 600 mW

Potentials: Supply for digital output modules (UO)

Supply Voltage24 V DC
Supply Voltage Range19.2 V DC ... 30 V DC (including all tolerances, including ripple)
Current drawmax. 8 A (provide external protection)
Power consumptionmax. 240 W (of which 560 mW with internal losses)
Protective circuitSurge protection; electronic (35 V, 0.5 s)
Protective circuitReverse polarity protection; parallel diode; with external 5 A fuse (only for commissioning)

Electrical isolation/isolation of the voltage ranges

Test voltage: 5 V supply of the local bus (UBus) / 24 V supply (I/Os)500 V AC, 50 Hz, 1 min.
Test voltage: 5 V supply of the local bus (UBus) / functional ground500 V AC, 50 Hz, 1 min.
Test voltage: 24 V supply (I/O) / functional ground500 V AC, 50 Hz, 1 min.

Connection technology

Connection nameAxioline F connector
Note on the connection methodPlease observe the information provided on conductor cross sections in the “Axioline F: system and installation” user manual.

Conductor connection

Connection MethodPush-in connection
Conductor cross section rigid0.2 mm² ... 1.5 mm²
Conductor cross section flexible0.2 mm² ... 1.5 mm²
Conductor cross section AWG24 ... 16
Stripping length8 mm

Axioline F connector

Connection MethodPush-in connection
Note on the connection methodPlease observe the information provided on conductor cross sections in the “Axioline F: system and installation” user manual.
Conductor cross section, rigid0.2 mm² ... 1.5 mm²
Conductor cross section, flexible0.2 mm² ... 1.5 mm²
Conductor cross section AWG24 ... 16
Stripping length8 mm

Ambient conditions

Ambient Temperature (Operation)-25 °C ... 60 °C
Degree of ProtectionIP20
Air pressure (operation)70 kPa ... 106 kPa (up to 3000 m above sea level)
Air pressure (storage/transport)70 kPa ... 106 kPa (up to 3000 m above sea level)
Ambient temperature (storage/transport)-40 °C ... 85 °C
Permissible humidity (operation)5 % ... 95 % (non-condensing)
Permissible humidity (storage/transport)5 % ... 95 % (non-condensing)

Standards and Regulations

Protection classIII (IEC 61140, EN 61140, VDE 0140-1)

Mounting

Mounting TypeDIN rail mounting
Mounting Positionany (no temperature derating)
Accessories

Why Proax for Phoenix Contact AXL F DO16 FLK 1H?

Proax is an authorized distributor of Phoenix Contact AXL F DO16 FLK 1H and one of Phoenix Contact's largest distributors in North America. Our highly skilled in-house technical team is ready to assist with any technical needs.

Have a question in mind? to help you get the right product as quickly as possible for your project. We're always here to help!

Short Lead Time
Highly Trained Staff
Live Chat
Technical Support
Local Inventory
60+ Years Experience
Additional Information

Alternate NamesAXLFDO16FLK1H
Pack Size1
Recommended

Available for order