AXL F DI16/4 XC 2F - Digital module

Axioline F, Digital input module, Digital inputs: 16, 24 V DC, connection technology: 4-conductor, Extreme conditions version, transmission speed in the local bus: 100 Mbps, degree of protection: IP20, including bus base module and Axioline F connectors

  • 16 digital inputs in accordance with EN 61131-2 type 1 and type 3
  • 24 V DC, 2.4 mA
  • Connection of sensors in 2-, 3-, and 4-conductor technology
  • Filter times can be adjusted in two increments: < 100 µs or 500 µs
  • Maximum input frequency: 5 kHz
  • Maximum permissible load current per sensor: 2 A
  • Maximum permissible load current of the module: 4 A (2 A for each group of a max. 8 sensors)
  • Minimum update time of < 100 μs
  • Device rating plate stored
  • Can be used under extreme ambient conditions
  • Extended temperature range of -40 °C ... +70 °C (see “Tested successfully: use under extreme ambient conditions” in the data sheet)
  • Partially coated PCBs
Technical Specifications

Dimensions

Width53.6 mm
Height129.9 mm
Depth54 mm
Note on dimensionsThe depth applies when a TH 35-7.5 DIN rail is used (in accordance with EN 60715).

Utilization restriction

EMC noteEMC: class A product, see manufacturer's declaration in the download area

Axioline F local bus

Number of interfaces2
Connection MethodBus base module
Transmission Speed100 Mbps

Module

ID code (hex)none
Input address area2 Byte
Output address area0 Byte
Required parameter data 3 Byte
Required configuration data 6 Byte

Digital:

Input nameDigital inputs
Description of the inputEN 61131-2 types 1 and 3
Number of Inputs16
Connection MethodPush-in connection
Connection technology4-conductor
Input voltage range "0" signal-3 V DC ... 5 V DC
Input voltage range "1" signal11 V DC ... 30 V DC
Nominal input voltage UIN24 V DC
Nominal input current at UIN2.4 mA
Input filter time500 µs (Default)
Input filter time< 100 µs
Protective circuitPolarity reversal protection of the inputs; electronic

Product properties

Product familyAxioline F
Typeblock modular
Mounting Positionany (no temperature derating)
Scope of deliveryincluding bus base module and Axioline F connectors
Special PropertiesExtreme conditions version

Insulation characteristics

Overvoltage categoryII (IEC 60664-1, EN 60664-1)
Pollution degree2 (IEC 60664-1, EN 60664-1)

Potentials: Axioline F local bus supply (UBus)

Supply Voltage5 V DC (via bus base module)
Current drawmax. 120 mA (HW 00)
Current drawmax. 60 mA (from HW 01)
Power consumptionmax. 600 mW (HW 00)
Power consumptionmax. 300 mW (from HW 01)

Potentials: Supply for digital input modules (UI)

Supply Voltage24 V DC
Supply Voltage Range19.2 V DC ... 30 V DC (including all tolerances, including ripple)
Current drawmax. 4 A (Sensor supply US)
Power consumptionmax. 120 W (of which 800 mW with internal losses)
Protective circuitSurge protection; electronic (35 V, 0.5 s)
Protective circuitReverse polarity protection; parallel diode; with external 5 A fuse (only for commissioning)

Supply: Sensor supply (US)

DesignationSensor supply (US)
Supply Voltage24 V DC (from UI)

Electrical isolation/isolation of the voltage ranges

Test voltage: 5 V supply of the local bus (UBus) / 24 V supply (I/Os)500 V AC, 50 Hz, 1 min.
Test voltage: 5 V supply of the local bus (UBus) / functional ground500 V AC, 50 Hz, 1 min.
Test voltage: 24 V supply (I/O) / functional ground500 V AC, 50 Hz, 1 min.

Connection technology

Connection nameAxioline F connector
Note on the connection methodPlease observe the information provided on conductor cross sections in the “Axioline F: system and installation” user manual.

Conductor connection

Connection MethodPush-in connection
Conductor cross section rigid0.2 mm² ... 1.5 mm²
Conductor cross section flexible0.2 mm² ... 1.5 mm²
Conductor cross section AWG24 ... 16
Stripping length8 mm

Axioline F connector

Connection MethodPush-in connection
Note on the connection methodPlease observe the information provided on conductor cross sections in the “Axioline F: system and installation” user manual.
Conductor cross section, rigid0.2 mm² ... 1.5 mm²
Conductor cross section, flexible0.2 mm² ... 1.5 mm²
Conductor cross section AWG24 ... 16
Stripping length8 mm

Ambient conditions

Ambient Temperature (Operation)-25 °C ... 60 °C (Standard, applications with UL approval, use in zone 2 potentially explosive area)
Ambient Temperature (Operation)-40 °C ... 70 °C (Extended, see section “Tested successfully: use under extreme ambient conditions” in the data sheet.)
Degree of ProtectionIP20
Air pressure (operation)70 kPa ... 106 kPa (up to 3000 m above sea level)
Air pressure (storage/transport)70 kPa ... 106 kPa (up to 3000 m above sea level)
Ambient temperature (storage/transport)-40 °C ... 85 °C
Permissible humidity (operation)5 % ... 95 % (non-condensing)
Permissible humidity (storage/transport)5 % ... 95 % (non-condensing)

Standards and Regulations

Protection classIII (IEC 61140, EN 61140, VDE 0140-1)

ATEX

Identification II 3 G Ex ec IIC T4 Gc
CertificateUL 20 ATEX 2441X
References to standardsEN IEC 60079-0, EN IEC 60079-7

UKEX

Identification II 3 G Ex ec IIC T4 Gc
CertificatePxCIMA22UKEX2701949X
References to standardsEN IEC 60079-0, EN IEC 60079-7

IECEx

IdentificationEx ec IIC T4 Gc
CertificateIECEx ULD 20.0026X
References to standardsIEC 60079-0 Ed. 7, IEC 60079-7 Ed. 5.1

UL, USA/Canada

IdentificationcULus
CertificateE238705

UL Ex, USA / Canada

IdentificationClass I, Zone 2, AEx ec IIC T4
IdentificationClass I, Division 2, Groups A, B, C, D, T4
IdentificationEx ec IIC T4 Gc X
CertificateE366272
References to standardsUL 60079-0 Ed. 7 / CSA C22.2 NO. 60079-0 Ed. 4
References to standardsUL 60079-7 Ed. 5 / CSA C22.2 NO. 60079-7 Ed. 2

CCC / China-Ex

IdentificationEx ec IIC T4 Gc
Certificate, 2021122309114456
References to standardsGB/T 3836.1-2021, GB/T 3836.3-2021

Mounting

Mounting TypeDIN rail mounting
Mounting Positionany (no temperature derating)
Accessories

Why Proax for Phoenix Contact AXL F DI16/4 XC 2F?

Proax is an authorized distributor of Phoenix Contact AXL F DI16/4 XC 2F and one of Phoenix Contact's largest distributors in North America. Our highly skilled in-house technical team is ready to assist with any technical needs.

Have a question in mind? to help you get the right product as quickly as possible for your project. We're always here to help!

Short Lead Time
Highly Trained Staff
Live Chat
Technical Support
Local Inventory
60+ Years Experience
Additional Information

Alternate NamesAXLFDI164XC2F
Pack Size1
Recommended

Available for order