AXL F IOL8 2H - Communication module

Axioline F, IO-Link master, IO-Link ports Class A: 8, connection method: Push-in connection, connection technology: 3-conductor, transmission speed in the local bus: 100 Mbps, degree of protection: IP20, including bus base module and Axioline F connectors

  • Connection of eight IO-Link devices
  • Alternatively: connection of one digital sensor or actuator per port
  • Connection of IO-Link devices in 3-conductor technology
  • Connection of sensors in 3-conductor technology
  • Connection of actuators in 2- and 3-conductor technology
  • Parameter data storage on the master
  • IO-Link specification V1.1.2
  • Substitute value behavior of inputs and outputs can be parameterized for each port
  • Supports IOL-CONF (firmware version 1.02 or later)
  • Device rating plate stored
Technical Specifications

Dimensions

Width35 mm
Height129.9 mm
Depth54 mm
Note on dimensionsThe depth applies when a TH 35-7.5 DIN rail is used (in accordance with EN 60715).

Axioline F local bus

Number of interfaces2
Connection MethodBus base module
Transmission Speed100 Mbps

Module

Process data channel512 bit
Input address area64 Byte
Output address area64 Byte

Digital

Description of the inputIO-Link ports in digital input (DI) mode
Number of Inputsmax. 8 (EN 61131-2 type 1)
Connection MethodPush-in connection
Connection technology3-conductor
Nominal input voltage UIN24 V DC
Input voltage range "0" signal-0.3 V DC ... 5 V DC
Input voltage range "1" signal11 V DC ... 30 V DC
Nominal input currenttyp. 2.5 mA
Sensor current per channelmax. 1 A (from L+/L-)
Input filter time1 µs

IO-Link

Number of Ports8
Connection MethodPush-in connection
Connection technology3-conductor
Port TypeClass A

Digital

Output descriptionIO-Link ports in digital output (DO) mode
Connection MethodPush-in connection
Connection technology2-, 3-conductor
Number of Outputsmax. 8
Nominal Output Voltage24 V DC
Nominal current per channel200 mA

Product properties

Product familyAxioline F
Typeblock modular
Mounting Positionany (no temperature derating)
Scope of deliveryincluding bus base module and Axioline F connectors

Insulation characteristics

Overvoltage categoryII (IEC 60664-1, EN 60664-1)
Pollution degree2 (IEC 60664-1, EN 60664-1)

Supply: IO-Link

Nominal voltage for I/O supply24 V DC
Supply Voltage Range18 V DC ... 30 V DC (including all tolerances, including ripple)
Nominal current for every IO-Link port1 A (at L+/L-)
Nominal current for every IO-Link port200 mA (at C/Q)
Protective circuitOverload protection for L+; electronically limited to 1.2 A
Protective circuitShort-circuit protection for L+; by switching off after 5 ms

Electrical isolation/isolation of the voltage ranges

Test voltage: 5 V supply of the local bus (UBus) / 24 V supply (I/Os)500 V AC, 50 Hz, 1 min.
Test voltage: 5 V supply of the local bus (UBus) / functional ground500 V AC, 50 Hz, 1 min.
Test voltage: 24 V supply (I/O) / functional ground500 V AC, 50 Hz, 1 min.

Connection technology

Connection nameAxioline F connector
Note on the connection methodPlease observe the information provided on conductor cross sections in the “Axioline F: system and installation” user manual.

Conductor connection

Connection MethodPush-in connection
Conductor cross section rigid0.2 mm² ... 1.5 mm²
Conductor cross section flexible0.2 mm² ... 1.5 mm²
Conductor cross section AWG24 ... 16
Stripping length8 mm

Axioline F connector

Connection MethodPush-in connection
Note on the connection methodPlease observe the information provided on conductor cross sections in the “Axioline F: system and installation” user manual.
Conductor cross section, rigid0.2 mm² ... 1.5 mm²
Conductor cross section, flexible0.2 mm² ... 1.5 mm²
Conductor cross section AWG24 ... 16
Stripping length8 mm

Ambient conditions

Ambient Temperature (Operation)-25 °C ... 60 °C
Degree of ProtectionIP20
Air pressure (operation)70 kPa ... 106 kPa (up to 3000 m above sea level)
Air pressure (storage/transport)70 kPa ... 106 kPa (up to 3000 m above sea level)
Ambient temperature (storage/transport)-40 °C ... 85 °C
Permissible humidity (operation)5 % ... 95 % (non-condensing)
Permissible humidity (storage/transport)5 % ... 95 % (non-condensing)

Standards and Regulations

Protection classIII (IEC 61140, EN 61140, VDE 0140-1)

Mounting

Mounting TypeDIN rail mounting
Mounting Positionany (no temperature derating)
Accessories

Why Proax for Phoenix Contact 1027843?

Proax is an authorized distributor of Phoenix Contact 1027843 and one of Phoenix Contact's largest distributors in North America. Our highly skilled in-house technical team is ready to assist with any technical needs.

Have a question in mind? to help you get the right product as quickly as possible for your project. We're always here to help!

Short Lead Time
Highly Trained Staff
Live Chat
Technical Support
Local Inventory
60+ Years Experience
Additional Information

Pack Size1
Recommended

Not in stock

Request lead time or order—we'll ensure quick delivery

Phoenix Contact Availability