Official Distributor
SKU
MPN
AXL F IMPULSE2 XC 1H
Weight
0.189 kg
AXL F IMPULSE2 XC 1H - Function module
Axioline F XC, Function module, 2 digital pulse interfaces for evaluating magnetostrictive position sensors with start/stop interface, Transmission speed in the local bus 100 MBit/s, Degree of protection IP20, including bus base module and Axioline F connectors
- 2 channels for magnetostrictive position sensors with start/stop interface
- 5 stop events per channel
- Automatic parameter upload
- 4 digital inputs
- Device rating plate stored
- Diagnostic and status indicators
- Can be used under extreme ambient conditions
- Extended temperature range of -40 °C ... +70 °C (see “Tested successfully: use under extreme ambient conditions” in the data sheet)
- Partially coated PCBs
Technical Specifications
Dimensions
Width | 35 mm |
Height | 126.1 mm |
Depth | 54 mm |
Note on dimensions | The depth applies when a TH 35-7.5 DIN rail is used (in accordance with EN 60715). |
Axioline F local bus
Number of interfaces | 2 |
Connection Method | Bus base module |
Transmission Speed | 100 Mbps |
Module
Input address area | 46 Byte |
Output address area | 46 Byte |
Required parameter data | 1 Byte |
Required configuration data | 7 Byte |
Digital:
Input name | Digital inputs |
Description of the input | EN 61131-2 types 1 and 3 |
Number of Inputs | 4 |
Connection Method | Push-in connection |
Connection technology | 1-conductor |
Input voltage range "0" signal | -3 V DC ... 5 V DC |
Input voltage range "1" signal | 11 V DC ... 30 V DC |
Nominal input voltage UIN | 24 V DC |
Nominal input current at UIN | 2.4 mA |
Input filter time | 250 µs |
Input filter time | 1000 µs |
Input filter time | 3000 µs |
Protective circuit | Polarity reversal protection of the inputs; parallel diode (30 V, 5 s) |
Product properties
Product family | Axioline F |
Type | block modular |
Special Properties | Extreme conditions version |
Encoder
Number | 2 |
Nominal Output Voltage | 24 V DC (UI - 0.5 V) |
Voltage range | 19.2 V DC ... 30 V DC (including all tolerances, including ripple) |
Current carrying capacity | typ. 500 mA |
Protective circuit | Surge protection; electronic (35 V, 0.5 s) |
Protective circuit | Short-circuit protection; electronic |
Protective circuit | Transient protection; Shielding |
Potentials: Axioline F local bus supply (UBus)
Supply Voltage | 5 V DC (via bus base module) |
Current draw | max. 150 mA |
Power consumption | max. 0.75 W |
Potentials: Feed-in of supply voltage (UI)
Supply Voltage | 24 V DC |
Supply Voltage Range | 19.2 V DC ... 30 V DC including all tolerances, including ripple |
Current draw | max. 30 mA (Supply of pulse interface, without encoder supply) |
Power consumption | max. 0.72 W (Supply of pulse interface, without encoder supply) |
Protective circuit | Surge protection; electronic (35 V, 0.5 s) |
Protective circuit | Reverse polarity protection; Polarity protection diode |
Protective circuit | Transient protection; Suppressor diode |
Electrical isolation/isolation of the voltage ranges
Test voltage: Logic | 500 V AC, 50 Hz, 1 min. |
Test voltage: Pulse I/O (24 V supply) | 500 V AC, 50 Hz, 1 min. |
Test voltage: Functional ground | 500 V AC, 50 Hz, 1 min. |
Connection technology
Connection name | Axioline F connector |
Note on the connection method | Please observe the information provided on conductor cross sections in the “Axioline F: system and installation” user manual. |
Conductor connection
Connection Method | Push-in connection |
Conductor cross section rigid | 0.2 mm² ... 1.5 mm² |
Conductor cross section flexible | 0.2 mm² ... 1.5 mm² |
Conductor cross section AWG | 24 ... 16 |
Stripping length | 8 mm |
Axioline F connector
Connection Method | Push-in connection |
Note on the connection method | Please observe the information provided on conductor cross sections in the “Axioline F: system and installation” user manual. |
Conductor cross section, rigid | 0.2 mm² ... 1.5 mm² |
Conductor cross section, flexible | 0.2 mm² ... 1.5 mm² |
Conductor cross section AWG | 24 ... 16 |
Stripping length | 8 mm |
Ambient conditions
Ambient Temperature (Operation) | -25 °C ... 60 °C (Standard) |
Ambient Temperature (Operation) | -40 °C ... 70 °C (Extended, see section “Tested successfully: use under extreme ambient conditions” in the data sheet.) |
Degree of Protection | IP20 (per manufacturer's declaration) |
Air pressure (operation) | 70 kPa ... 106 kPa (up to 3000 m above sea level) |
Air pressure (storage/transport) | 70 kPa ... 106 kPa (up to 3000 m above sea level) |
Ambient temperature (storage/transport) | -40 °C ... 85 °C |
Permissible humidity (operation) | 5 % ... 95 % (non-condensing) |
Permissible humidity (storage/transport) | 5 % ... 95 % (non-condensing) |
Standards and Regulations
Protection class | III (IEC 61140, EN 61140, VDE 0140-1) |
Mounting
Mounting Type | DIN rail mounting |
Accessories
Why Proax for Phoenix Contact 2702655?
Proax is an authorized distributor of Phoenix Contact 2702655 and one of Phoenix Contact's largest distributors in North America. Our highly skilled in-house technical team is ready to assist with any technical needs.
Have a question in mind? to help you get the right product as quickly as possible for your project. We're always here to help!
Short Lead Time
Highly Trained Staff
Live Chat
Technical Support
Local Inventory
60+ Years Experience
Additional Information
Pack Size | 1 |
Recommended
- 2688093 - Axioline F, Function module, Counter inputs: 2, Incremental encoder inputs: 2, Symmetrical and asymmetrical encoders, Digital inputs: 8, 24 V DC, Digital outputs: 2, 24 V DC, transmission speed in the local bus: 100 Mbps, degree of protection: IP20, including bus base module and Axioline F connectors
- 2701239 - Axioline F, Function module, Counter inputs: 2, Incremental encoder inputs: 2, Symmetrical and asymmetrical encoders, Digital inputs: 8, 24 V DC, Digital outputs: 2, 24 V DC, Extreme conditions version, transmission speed in the local bus: 100 Mbps, degree of protection: IP20, including bus base module and Axioline F connectors
- 2702071 - Axioline F, Digital I/O module, Digital inputs: 8, 24 V DC, connection technology: 3-conductor, Digital outputs: 8, 24 V DC, 500 mA, connection technology: 3-conductor, transmission speed in the local bus: 100 Mbps, degree of protection: IP20, including bus base module and Axioline F connectors