Official Distributor
SKU
Weight
0.126 kg
Series MINI-MCR
MINI MCR-2-F-UI - Frequency measuring transducer
Universally configurable frequency transducer for converting frequency (Hz/rpm) and PWM signals into standard signals. Sensor voltages greater than 8.2 V DC are possible in combination with MINI MCR-2-SPS 1033202. Screw connection technology.
Technical Specifications
Utilization restriction
EMC note | EMC: class A product, see manufacturer's declaration in the download area |
Product properties
Product family | MINI Analog Pro |
No. of channels | 1 |
Type | Signal conditioner |
Configuration | DIP switches |
Configuration | Software |
Configuration | App |
Insulation characteristics
Overvoltage category | II |
Pollution degree | 2 |
Functionality
Configuration | DIP switches |
Configuration | Software |
Configuration | App |
Electrical properties
Step response (0–99%) | < 35 ms (f > 500 Hz) |
Maximum temperature coefficient | 0.01 %/K |
Maximum transmission error | 0.1 % (Frequency (Hz/rpm)) |
Maximum transmission error | 1 % (PWM signal) |
Electrical isolation Input/output/power supply
Rated Insulation Voltage | 300 Vrms |
Test voltage | 3 kV AC (50 Hz, 60 s) |
Insulation | Reinforced insulation according to IEC/EN 61010-1 |
Supply
Nominal Supply Voltage | 24 V DC |
Supply Voltage Range | 9.6 V DC ... 30 V DC (The DIN rail connector (ME 6,2 TBUS-2 1,5/5-ST-3,81 GN, item no. 2869728) can be used to bridge the supply voltage. It can be snapped onto a 35 mm DIN rail in accordance with EN 60715) |
Typical current consumption | 32 mA (24 V DC) |
Typical current consumption | 63 mA (12 V DC) |
Power consumption | ≤ 1 W (at IOUT = 20 mA, 9.6 V DC, 600 Ω load) |
Measurement: Frequency
Available Input Sources | NAMUR initiators |
Available Input Sources | NPN/PNP transistor outputs |
Available Input Sources | Floating contact (dry contact) |
Available Input Sources | Frequency generator |
Available Input Sources | Incremental encoder (speed only) |
Available Input Sources | HTL encoders |
Available Input Sources | TTL rotary transducer |
Available Input Sources | S0 signal |
Max. voltage input signal | 30 V (incl. DC voltage) |
Voltage measuring range | ≥ 2 V |
Frequency measuring range | 0.002 Hz ... 200 kHz |
PWM (range) | 0.002 Hz ... 60 Hz (Duty cycle 2 ... 98 %) |
PWM (range) | 60 Hz ... 300 Hz (Duty cycle: 5 ... 95 %) |
PWM (range) | 300 Hz ... 600 Hz (Duty cycle: 10 ... 90 %) |
PWM (range) | 600 Hz ... 1000 Hz (Duty cycle 20 ... 80 %) |
Signal
Number of Inputs | 1 |
Input Signal | Frequency |
Switching: Transistor
Number of Outputs | 1 |
Contact switching type | 1 N/O contact |
Minimum Switching Voltage | 1 V |
Maximum Switching Voltage | 30 V DC |
Min. switching current | 100 µA |
Max. switching current | 100 mA (30 V) |
Signal: Voltage/current
Number of Outputs | 1 |
Configurable/programmable | Yes |
Voltage output signal | 0 V ... 10 V (via DIP switch) |
Voltage output signal | 2 V ... 10 V (via DIP switch) |
Voltage output signal | 0 V ... 5 V (via DIP switch) |
Voltage output signal | 1 V ... 5 V (via DIP switch) |
Voltage output signal | 0 V ... 10.5 V (can be set via software) |
Max. voltage output signal | 12.3 V |
Current Output Signal | 0 mA ... 20 mA (via DIP switch) |
Current Output Signal | 4 mA ... 20 mA (via DIP switch) |
Current Output Signal | 0 mA ... 10 mA (via DIP switch) |
Current Output Signal | 2 mA ... 10 mA (via DIP switch) |
Current Output Signal | 0 mA ... 21 mA (can be set via software) |
Max. current output signal | 24.6 mA |
Load/output load voltage output | ≥ 10 kΩ |
Load/Output Load Current Output | ≤ 600 Ω (20 mA) |
Ripple | < 20 mVPP (600 Ω) |
Ripple | < 20 mVPP (600 Ω) |
Connection data
Connection Method | Screw connection |
Stripping length | 10 mm |
Screw thread | M3 |
Conductor cross section rigid | 0.2 mm² ... 1.5 mm² (with ferrule) |
Conductor cross section rigid | 0.14 mm² ... 2.5 mm² (without ferrule) |
Conductor cross section flexible | 0.14 mm² ... 2.5 mm² |
Conductor cross section AWG | 24 ... 12 (flexible) |
Tightening torque | 0.5 Nm ... 0.6 Nm |
Ex data
Ex installation (EPL) | Gc |
Ex installation (EPL) | Div. 2 |
Signaling
Status display | Green LED (supply voltage) |
Status display | Yellow LED (switching output) |
Error indication | Red LED |
Dimensions
Width | 6.2 mm |
Height | 109.81 mm |
Depth | 119.2 mm |
Material specifications
Color | gray (RAL 7042) |
Housing Material | PBT |
Fire protection for rail vehicles (DIN EN 45545-2) R22 | HL 1 - HL 2 |
Fire protection for rail vehicles (DIN EN 45545-2) R23 | HL 1 - HL 2 |
Fire protection for rail vehicles (DIN EN 45545-2) R24 | HL 1 - HL 2 |
Ambient conditions
Degree of Protection | IP20 (not assessed by UL) |
Ambient Temperature (Operation) | -40 °C ... 70 °C |
Ambient temperature (storage/transport) | -40 °C ... 85 °C |
Altitude | ≤ 2000 m |
Permissible humidity (operation) | 5 % ... 95 % (non-condensing) |
CE
Certificate | CE-compliant |
ATEX
Identification | II 3 G Ex ec IIC T4 Gc |
Certificate | BVS 20 ATEX E 024 X |
UKCA Ex (UKEX)
Identification | II 3 G Ex ec IIC T4 Gc |
Certificate | PxCIF21UKEX2902049X |
IECEx
Identification | Ex ec IIC T4 Gc |
Certificate | IECEx BVS 20.0017X |
UL, USA/Canada
Identification | UL 508 Listed |
Identification | Class I, Div. 2, Groups A, B, C, D T5 |
Identification | Class I, Zone 2, Group IIC T5 |
Shipbuilding approval
Certificate | DNV GL TAA000021E Rev. 1 |
EAC Ex
Identification | 2Ex ec IIC T4 Gc |
Certificate | BY/112 02.01 TP012 103.01 00081 |
DNV GL data
Temperature | B |
Humidity | B |
Vibration | A |
EMC | A |
Enclosure | Required protection according to the Rules shall be provided upon installation on board |
EMC data
Noise immunity | EN 61000-6-2 |
Note | When being exposed to interference, there may be minimal deviations. |
Electromagnetic compatibility | Conformance with EMC directive |
Noise emission | EN 61000-6-4 |
Electrostatic discharge
Standards/regulations | EN 61000-4-2 |
Comments | Safety measures must be taken to prevent electrostatic discharge. |
Electromagnetic HF field
Designation | Electromagnetic RF field |
Standards/regulations | EN 61000-4-3 |
Typical deviation from the measuring range final value | 0.2 % |
Fast transients (burst)
Designation | Fast transients (burst) |
Standards/regulations | EN 61000-4-4 |
Typical deviation from the measuring range final value | 0.1 % |
Surge current load (surge)
Standards/regulations | EN 61000-4-5 |
Conducted interference
Designation | Conducted interferences |
Standards/regulations | EN 61000-4-6 |
Typical deviation from the measuring range final value | 2.8 % |
Mounting
Mounting Type | DIN rail mounting |
Assembly instructions | The DIN rail connector can be used for bridging the supply voltage. It can be snapped onto a 35 mm EN 60715 DIN rail. |
Mounting Position | any |
Accessories
Why Proax for Phoenix Contact 2902056?
Proax is an authorized distributor of Phoenix Contact 2902056 and one of Phoenix Contact's largest distributors in North America. Our highly skilled in-house technical team is ready to assist with any technical needs.
Have a question in mind? to help you get the right product as quickly as possible for your project. We're always here to help!
Short Lead Time
Highly Trained Staff
Live Chat
Technical Support
Local Inventory
60+ Years Experience
Additional Information
Pack Size | 1 |
Recommended