MINI MCR-2-CVCS-PT - Constant voltage source
Constant voltage/current source with plug-in connection technology, input voltage: 9.6 V DC ... 30 V DC. Output voltage: 1.25 V DC ...10 V DC or output current: 2.5 mA ... 20 mA can be set. Configurable via DIP switch. Push-in connection technology.
Technical Specifications
Note
Utilization restriction | EMC: class A product, see manufacturer's declaration in the download area |
Dimensions
Width | 6.2 mm |
Height | 109.81 mm |
Depth | 119.2 mm |
Ambient conditions
Ambient Temperature (Operation) | -40 °C ... 70 °C |
Ambient temperature (storage/transport) | -40 °C ... 85 °C |
Permissible humidity (operation) | 5 % ... 95 % (non-condensing) |
Degree of Protection | IP20 (not assessed by UL) |
Noise immunity | EN 61000-6-2 When being exposed to interference, there may be minimal deviations. |
Input data
Designation | Voltage input |
Voltage input signal | 9.6 V DC ... 30 V DC |
Transmitter supply voltage | 10 V |
Output data
Output name | Voltage output / current output |
Configurable/programmable | Yes |
Max. output voltage | 10 V DC |
Max. output voltage | 8.75 V DC |
Max. output voltage | 7.5 V DC |
Max. output voltage | 6.25 V DC |
Max. output voltage | 5 V DC |
Max. output voltage | 3.75 V DC |
Max. output voltage | 2.5 V DC |
Max. output voltage | 1.25 V DC |
Max. output current | 20 mA |
Max. output current | 17.5 mA |
Max. output current | 15 mA |
Max. output current | 12.5 mA |
Max. output current | 10 mA |
Max. output current | 7.5 mA |
Max. output current | 5 mA |
Max. output current | 2.5 mA |
Output voltage with wire break | 13.5 V |
Output Current | ≤ 30 mA |
Short-circuit current | > 32 mA |
Load/Output Load Current Output | ≤ 600 Ω (20 mA) |
Ripple | < 20 mVPP (at 600 Ω) |
Power supply
Supply Voltage Range | 9.6 V DC ... 30 V DC (The DIN rail bus connector (ME 6,2 TBUS-2 1,5/5-ST-3,81 GN, Item No. 2869728) can be used to bridge the supply voltage. It can be snapped onto a 35 mm DIN rail according to EN 60715)) |
Typical current consumption | < 42 mA (24 V DC) |
Typical current consumption | < 85 mA (12 V DC) |
Power consumption | < 1.1 W (9.6 V DC) |
Connection data
Connection Method | Push-in connection |
Stripping length | 10 mm |
Conductor cross section solid | 0.2 mm² ... 2.5 mm² (with ferrule) |
Conductor cross section solid | 0.14 mm² ... 2.5 mm² (without ferrule) |
Conductor cross section flexible | 0.14 mm² ... 2.5 mm² |
Conductor cross section AWG | 24 ... 12 (flexible) |
General
Maximum transmission error | ≤ 0.1 % (of final value) |
Maximum temperature coefficient | < 0.01 %/K |
Electrical isolation | Reinforced insulation in accordance with IEC 61010-1 |
Overvoltage category | II |
Degree of pollution | 2 |
Rated Insulation Voltage | 300 V (effective) |
Test voltage, input/output/supply | 3 kV (50 Hz, 1 min.) |
Electromagnetic compatibility | Conformance with EMC directive |
Noise emission | EN 61000-6-4 |
Noise immunity | EN 61000-6-2 When being exposed to interference, there may be minimal deviations. |
Housing Material | PBT |
Mounting Position | any |
Assembly instructions | The T connector can be used to bridge the supply voltage. It can be snapped onto a 35 mm DIN rail according to EN 60715. |
Configuration | DIP switches |
Fire protection for rail vehicles (DIN EN 45545-2) R22 | HL 1 - HL 2 |
Fire protection for rail vehicles (DIN EN 45545-2) R23 | HL 1 - HL 2 |
Fire protection for rail vehicles (DIN EN 45545-2) R24 | HL 1 - HL 2 |
Standards and Regulations
Electromagnetic compatibility | Conformance with EMC directive |
Noise emission | EN 61000-6-4 |
Designation | GB Standard |
Standards/regulations | GB 3836.1 |
Standards/regulations | GB 3836.8 |
Electrical isolation | Reinforced insulation in accordance with IEC 61010-1 |
Environmental Product Compliance
REACh SVHC | Lead 7439-92-1 |
China RoHS | Environmentally Friendly Use Period = 50 years |
China RoHS | For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration” |
Accessories
Why Proax for Phoenix Contact 2902065?
Proax is an authorized distributor of Phoenix Contact 2902065 and one of Phoenix Contact's largest distributors in North America. Our highly skilled in-house technical team is ready to assist with any technical needs.
Have a question in mind? to help you get the right product as quickly as possible for your project. We're always here to help!
Short Lead Time
Highly Trained Staff
Live Chat
Technical Support
Local Inventory
60+ Years Experience
Additional Information
Pack Size | 1 |
Recommended
- Convertisseur de fréquence à configuration universelle, pour la conversion des signaux de fréquence (Hz/rpm) et de modulation d'impulsions en largeur, en signaux normalisés. Tensions de capteur supérieure à 8,2 V DC, en relation avec MINI MCR-2-SPS-PT 1033201 possible. Technologie de raccordement Push-in.