MINI MCR-2-POT-UI-PT - Resistance/potiposition transducer
Configurable potiposition transducer with plug-in connection technology for connecting potentiometers from 0 Ω ... 100 Ω to 0 kΩ ... 100 kΩ. Configurable via DIP switch or software. push-in connection technology, standard configuration
Technical Specifications
Utilization restriction
| EMC note | EMC: class A product, see manufacturer's declaration in the download area |
Product properties
| Product family | MINI Analog Pro |
| No. of channels | 1 |
| Configuration | DIP switches |
| Configuration | Software |
| Configuration | App |
Insulation characteristics
| Overvoltage category | II |
| Pollution degree | 2 |
Functionality
| Configuration | DIP switches |
| Configuration | Software |
| Configuration | App |
Electrical properties
| Electrical isolation | 3-way isolation |
| Protective circuit | Transient protection |
| Step response (0–99%) | < 60 ms |
| Maximum temperature coefficient | 0.01 %/K |
| Temperature coefficient, typical | 0.01 %/K |
| Maximum transmission error | < 0.1 % (R < 240 Ω = < 0,2 %) |
Electrical isolation Input/output/power supply
| Rated Insulation Voltage | 300 Vrms |
| Test voltage | 3 kV AC (50 Hz, 60 s) |
| Insulation | Reinforced insulation according to IEC/EN 61010-1 |
Supply
| Nominal Supply Voltage | 24 V DC |
| Supply Voltage Range | 9.6 V DC ... 30 V DC (The DIN rail connector (ME 6,2 TBUS-2 1,5/5-ST-3,81 GN, item no. 2869728) can be used to bridge the supply voltage. It can be snapped onto a 35 mm DIN rail in accordance with EN 60715) |
| Typical current consumption | 33 mA (24 V DC) |
| Typical current consumption | 68 mA (12 V DC) |
| Power consumption | ≤ 850 mW (at IOUT = 20 mA, 9.6 V DC, 600 Ω load) |
Signal: Resistance
| Number of Inputs | 1 |
| Available Input Sources | 3-wire potentiometer |
| Resistance range | 0 Ω ... 100 Ω |
| Resistance range | 0 Ω ... 100 kΩ |
Signal: Voltage/current
| Number of Outputs | 1 |
| Voltage output signal | 1 V ... 5 V (via DIP switch) |
| Voltage output signal | 10 V ... 0 V (via DIP switch) |
| Voltage output signal | 0 V ... 5 V (via DIP switch) |
| Voltage output signal | 0 V ... 10 V (via DIP switch) |
| Voltage output signal | 0 V ... 10.5 V (can be set via software) |
| Max. voltage output signal | 12.3 V |
| Non-load voltage | < 17.5 V |
| Current Output Signal | 0 mA ... 20 mA (via DIP switch) |
| Current Output Signal | 4 mA ... 20 mA (via DIP switch) |
| Current Output Signal | 20 mA ... 0 mA (via DIP switch) |
| Current Output Signal | 20 mA ... 4 mA (via DIP switch) |
| Current Output Signal | 0 mA ... 21 mA (can be set via software) |
| Max. current output signal | 24.6 mA |
| Short-circuit current | < 31.5 mA |
| Load/output load voltage output | ≥ 10 kΩ |
| Load/Output Load Current Output | ≤ 600 Ω (20 mA) |
| Ripple | < 20 mVPP |
| Ripple | < 20 mVPP (10 kΩ) |
| Resolution, outputs (voltage) | 1 mV |
| Resolution, outputs (current) | 2 µA |
| Behavior in the event of a sensor error | configurable |
Connection data
| Connection Method | Push-in connection |
| Stripping length | 10 mm |
| Conductor cross section rigid | 0.2 mm² ... 2.5 mm² (with ferrule) |
| Conductor cross section rigid | 0.14 mm² ... 2.5 mm² (without ferrule) |
| Conductor cross section flexible | 0.14 mm² ... 2.5 mm² |
| Conductor cross section AWG | 24 ... 12 (flexible) |
Ex data
| Ex installation (EPL) | Gc |
| Ex installation (EPL) | Div. 2 |
Data: IFS interface
| Connection Method | Micro USB type B |
Signaling
| Operating voltage display | Green LED |
| Error indication | Red LED |
Dimensions
| Width | 6.2 mm |
| Height | 109.81 mm |
| Depth | 119.2 mm |
Material specifications
| Color | gray (RAL 7042) |
| Housing Material | PBT |
| Fire protection for rail vehicles (DIN EN 45545-2) R22 | HL 1 - HL 2 |
| Fire protection for rail vehicles (DIN EN 45545-2) R23 | HL 1 - HL 2 |
| Fire protection for rail vehicles (DIN EN 45545-2) R24 | HL 1 - HL 2 |
Ambient conditions
| Degree of Protection | IP20 (not assessed by UL) |
| Ambient Temperature (Operation) | -40 °C ... 70 °C |
| Ambient temperature (storage/transport) | -40 °C ... 85 °C |
| Altitude | ≤ 2000 m |
| Permissible humidity (operation) | 5 % ... 95 % (non-condensing) |
CE
| Certificate | CE-compliant |
ATEX
| Identification | II 3 G Ex ec IIC T4 Gc |
| Certificate | BVS 20 ATEX E 024 X |
UKCA Ex (UKEX)
| Identification | II 3 G Ex ec IIC T4 Gc |
| Certificate | PxCIF21UKEX2902049X |
IECEx
| Identification | Ex ec IIC T4 Gc |
| Certificate | IECEx BVS 20.0017X |
UL, USA/Canada
| Identification | UL 508 Listed |
| Identification | Class I, Div. 2, Groups A, B, C, D T5 |
| Identification | Class I, Zone 2, Group IIC T5 |
Shipbuilding approval
| Certificate | DNV GL TAA00002UA |
EAC Ex
| Identification | 2Ex ec IIC T4 Gc |
| Certificate | BY/112 02.01 TP012 103.01 00079 |
DNV GL data
| Temperature | B |
| Humidity | B |
| Vibration | A |
| EMC | A |
| Enclosure | Required protection according to the Rules shall be provided upon installation on board |
EMC data
| Noise immunity | EN 61000-6-2 |
| Note | When being exposed to interference, there may be minimal deviations. |
| Electromagnetic compatibility | Conformance with EMC directive |
| Noise emission | EN 61000-6-4 |
Electrostatic discharge
| Standards/regulations | EN 61000-4-2 |
| Comments | Safety measures must be taken to prevent electrostatic discharge. |
Electromagnetic HF field
| Designation | Electromagnetic RF field |
| Standards/regulations | EN 61000-4-3 |
| Typical deviation from the measuring range final value | 0.2 % |
Fast transients (burst)
| Designation | Fast transients (burst) |
| Standards/regulations | EN 61000-4-4 |
| Typical deviation from the measuring range final value | 0.4 % |
Surge current load (surge)
| Standards/regulations | EN 61000-4-5 |
Conducted interference
| Designation | Conducted interferences |
| Standards/regulations | EN 61000-4-6 |
| Typical deviation from the measuring range final value | 0.2 % |
Standards and Regulations
| Electrical isolation | 3-way isolation |
Mounting
| Mounting Type | DIN rail mounting |
| Assembly instructions | The DIN rail connector can be used for bridging the supply voltage. It can be snapped onto a 35 mm EN 60715 DIN rail. |
| Mounting Position | any |
Accessories
Why Proax for Phoenix Contact 2902017?
Proax is an authorized distributor of Phoenix Contact 2902017 and one of Phoenix Contact's largest distributors in North America. Our highly skilled in-house technical team is ready to assist with any technical needs.
Have a question in mind? to help you get the right product as quickly as possible for your project. We're always here to help!
Short Lead Time
Highly Trained Staff
Live Chat
Technical Support
Local Inventory
60+ Years Experience
Additional Information
| Pack Size | 1 |
Recommended