Proax

Currency
0 Items
proax logo
Cart
Phoenix ContactOfficial Distributor

By Phoenix Contact

SKU
MPN
2902058
Weight
0.118 kg
Series MINI-MCR

MINI MCR-2-F-UI-PT - Frequency measuring transducer

Universally configurable frequency transducer for converting frequency (Hz/rpm) and PWM signals into standard signals. Sensor voltages greater than 8.2 V DC are possible in combination with MINI MCR-2-SPS-PT 1033201. Push-in connection technology.

Technical Specifications

Utilization restriction

EMC noteEMC: class A product, see manufacturer's declaration in the download area

Product properties

Product familyMINI Analog Pro
No. of channels1
TypeSignal conditioner
ConfigurationDIP switches
ConfigurationSoftware
ConfigurationApp

Insulation characteristics

Overvoltage categoryII
Pollution degree2

Functionality

ConfigurationDIP switches
ConfigurationSoftware
ConfigurationApp

Electrical properties

Step response (0–99%)< 35 ms (f > 500 Hz)
Maximum temperature coefficient0.01 %/K
Maximum transmission error0.1 % (Frequency (Hz/rpm))
Maximum transmission error1 % (PWM signal)

Electrical isolation Input/output/power supply

Rated Insulation Voltage300 Vrms
Test voltage3 kV AC (50 Hz, 60 s)
InsulationReinforced insulation according to IEC/EN 61010-1

Supply

Nominal Supply Voltage24 V DC
Supply Voltage Range9.6 V DC ... 30 V DC (The DIN rail connector (ME 6,2 TBUS-2 1,5/5-ST-3,81 GN, item no. 2869728) can be used to bridge the supply voltage. It can be snapped onto a 35 mm DIN rail in accordance with EN 60715)
Typical current consumption32 mA (24 V DC)
Typical current consumption63 mA (12 V DC)
Power consumption≤ 1 W (at IOUT = 20 mA, 9.6 V DC, 600 Ω load)

Measurement: Frequency

Available Input SourcesNAMUR initiators
Available Input SourcesNPN/PNP transistor outputs
Available Input SourcesFloating contact (dry contact)
Available Input SourcesFrequency generator
Available Input SourcesIncremental encoder (speed only)
Available Input SourcesHTL encoders
Available Input SourcesTTL rotary transducer
Available Input SourcesS0 signal
Max. voltage input signal30 V (incl. DC voltage)
Voltage measuring range≥ 2 V
Frequency measuring range0.002 Hz ... 200 kHz
PWM (range)0.002 Hz ... 60 Hz (Duty cycle 2 ... 98 %)
PWM (range)60 Hz ... 300 Hz (Duty cycle: 5 ... 95 %)
PWM (range)300 Hz ... 600 Hz (Duty cycle: 10 ... 90 %)
PWM (range)600 Hz ... 1000 Hz (Duty cycle 20 ... 80 %)

Signal

Number of Inputs1
Input SignalFrequency

Switching: Transistor

Number of Outputs1
Contact switching type1 N/O contact
Minimum Switching Voltage1 V
Maximum Switching Voltage30 V DC
Min. switching current100 µA
Max. switching current100 mA (30 V)

Signal: Voltage/current

Number of Outputs1
Configurable/programmableYes
Voltage output signal0 V ... 10 V (via DIP switch)
Voltage output signal2 V ... 10 V (via DIP switch)
Voltage output signal0 V ... 5 V (via DIP switch)
Voltage output signal1 V ... 5 V (via DIP switch)
Voltage output signal0 V ... 10.5 V (can be set via software)
Max. voltage output signal12.3 V
Current Output Signal0 mA ... 20 mA (via DIP switch)
Current Output Signal4 mA ... 20 mA (via DIP switch)
Current Output Signal0 mA ... 10 mA (via DIP switch)
Current Output Signal2 mA ... 10 mA (via DIP switch)
Current Output Signal0 mA ... 21 mA (can be set via software)
Max. current output signal24.6 mA
Load/output load voltage output≥ 10 kΩ
Load/Output Load Current Output≤ 600 Ω (20 mA)
Ripple< 20 mVPP (600 Ω)
Ripple< 20 mVPP (600 Ω)

Connection data

Connection MethodPush-in connection
Stripping length10 mm
Conductor cross section rigid0.2 mm² ... 2.5 mm² (with ferrule)
Conductor cross section rigid0.14 mm² ... 2.5 mm² (without ferrule)
Conductor cross section flexible0.14 mm² ... 2.5 mm²
Conductor cross section AWG24 ... 12 (flexible)

Ex data

Ex installation (EPL)Gc
Ex installation (EPL)Div. 2

Signaling

Status displayGreen LED (supply voltage)
Status displayYellow LED (switching output)
Error indicationRed LED

Dimensions

Width6.2 mm
Height109.81 mm
Depth119.2 mm

Material specifications

Colorgray (RAL 7042)
Housing MaterialPBT
Fire protection for rail vehicles (DIN EN 45545-2) R22HL 1 - HL 2
Fire protection for rail vehicles (DIN EN 45545-2) R23HL 1 - HL 2
Fire protection for rail vehicles (DIN EN 45545-2) R24HL 1 - HL 2

Ambient conditions

Degree of ProtectionIP20 (not assessed by UL)
Ambient Temperature (Operation)-40 °C ... 70 °C
Ambient temperature (storage/transport)-40 °C ... 85 °C
Altitude≤ 2000 m
Permissible humidity (operation)5 % ... 95 % (non-condensing)

CE

CertificateCE-compliant

ATEX

Identification II 3 G Ex ec IIC T4 Gc
CertificateBVS 20 ATEX E 024 X

UKCA Ex (UKEX)

Identification II 3 G Ex ec IIC T4 Gc
CertificatePxCIF21UKEX2902049X

IECEx

IdentificationEx ec IIC T4 Gc
CertificateIECEx BVS 20.0017X

UL, USA/Canada

IdentificationUL 508 Listed
IdentificationClass I, Div. 2, Groups A, B, C, D T5
IdentificationClass I, Zone 2, Group IIC T5

Shipbuilding approval

CertificateDNV GL TAA000021E Rev. 1

EAC Ex

Identification 2Ex ec IIC T4 Gc
CertificateBY/112 02.01 TP012 103.01 00081

DNV GL data

TemperatureB
HumidityB
VibrationA
EMCA
EnclosureRequired protection according to the Rules shall be provided upon installation on board

EMC data

Noise immunityEN 61000-6-2
NoteWhen being exposed to interference, there may be minimal deviations.
Electromagnetic compatibilityConformance with EMC directive
Noise emissionEN 61000-6-4

Electrostatic discharge

Standards/regulationsEN 61000-4-2
CommentsSafety measures must be taken to prevent electrostatic discharge.

Electromagnetic HF field

DesignationElectromagnetic RF field
Standards/regulationsEN 61000-4-3
Typical deviation from the measuring range final value0.2 %

Fast transients (burst)

DesignationFast transients (burst)
Standards/regulationsEN 61000-4-4
Typical deviation from the measuring range final value0.1 %

Surge current load (surge)

Standards/regulationsEN 61000-4-5

Conducted interference

DesignationConducted interferences
Standards/regulationsEN 61000-4-6
Typical deviation from the measuring range final value2.8 %

Mounting

Mounting TypeDIN rail mounting
Assembly instructionsThe DIN rail connector can be used for bridging the supply voltage. It can be snapped onto a 35 mm EN 60715 DIN rail.
Mounting Positionany
Accessories

Why Proax for Phoenix Contact MINI MCR-2-F-UI-PT?

Proax is an authorized distributor of Phoenix Contact MINI MCR-2-F-UI-PT and one of Phoenix Contact's largest distributors in North America. Our highly skilled in-house technical team is ready to assist with any technical needs.

Have a question in mind? to help you get the right product as quickly as possible for your project. We're always here to help!

Short Lead Time
Highly Trained Staff
Live Chat
Technical Support
Local Inventory
60+ Years Experience
Additional Information

Alternate NamesMINIMCR2FUIPT
Pack Size1
Recommended

Available for order