AXL F EX IS DO4 SD 21-60 XC 1F - Digital module

Axioline F, Digital output module, Digital outputs: 4, 21 V, connection technology: 2-conductor, Extreme conditions version, Intrinsically safe, Solenoid drive, transmission speed in the local bus: 100 Mbps, degree of protection: IP20, including bus base module and Axioline F connectors

  • Four 21 V DC - 60 mA digital output-powered control signals for solenoid drives
  • Intrinsically safe digital outputs with connection to Zone 1, Zone 0 or Division 1
  • Can be used under extreme ambient conditions
  • Extended temperature range of -40 °C ... +70 °C (see “Tested successfully: use under extreme ambient conditions” in the data sheet)
Technical Specifications

Dimensions

Width53.6 mm
Height129.9 mm
Depth77.14 mm
Note on dimensionsThe depth applies when a TH 35-7.5 DIN rail is used (in accordance with EN 60715).

Utilization restriction

EMC noteEMC: class A product, see manufacturer's declaration in the download area
CCCex noteUse in potentially explosive areas is not permitted in China.

Material specifications

Colortraffic grey A RAL 7042

Axioline F local bus

No. of channels2
Connection MethodBus base module
Transmission Speed100 Mbps

Module

Input address area0 Byte
Output address area1 Byte
Required parameter data 12 Byte
Required configuration data 6 Byte

Digital:

Output nameDigital outputs
Connection MethodPush-in connection
Connection technology2-conductor
Number of Outputs4
Output Voltage21 V
Maximum Output Current per channel60 mA
Nominal Output Voltage21 V

Product properties

Product familyAxioline F
Typeblock modular
Scope of deliveryincluding bus base module and Axioline F connectors
Special PropertiesSolenoid drive
Special PropertiesExtreme conditions version
Special PropertiesIntrinsically safe

Potentials: Axioline F local bus supply (UBus)

Supply Voltage5 V DC (via bus base module)
Current drawmax. 60 mA
Current drawtyp. 40 mA

Potentials: Supply for digital output modules (UO)

Supply Voltage24 V DC
Supply Voltage Range19.2 V DC ... 30 V DC (including all tolerances, including ripple)
Current drawmax. 420 mA

Electrical isolation/isolation of the voltage ranges

Test voltage: 5 V supply of the local bus (UBus) / 24 V supply (I/Os)500 V AC, 50 Hz, 1 min.
Test voltage: 5 V supply of the local bus (UBus) / functional ground500 V AC, 50 Hz, 1 min.
Test voltage: 24 V supply (I/O) / functional ground500 V AC, 50 Hz, 1 min.
Test voltage: Field to functional earth500 V AC, 50 Hz, 1 min.
Test voltage: Field to 5V or 24V supplies1500 V AC, 50 Hz, 1 min.

Connection technology

Connection nameAxioline F connector
Note on the connection methodPlease observe the information provided on conductor cross sections in the “Axioline F: system and installation” user manual.

Conductor connection

Connection MethodPush-in connection
Conductor cross section rigid0.2 mm² ... 1.5 mm²
Conductor cross section flexible0.2 mm² ... 1.5 mm²
Conductor cross section AWG24 ... 16
Stripping length8 mm

Axioline F connector

Connection MethodPush-in connection
Note on the connection methodPlease observe the information provided on conductor cross sections in the “Axioline F: system and installation” user manual.
Conductor cross section, rigid0.2 mm² ... 1.5 mm²
Conductor cross section, flexible0.2 mm² ... 1.5 mm²
Conductor cross section AWG24 ... 16
Stripping length8 mm

Ambient conditions

Ambient Temperature (Operation)-25 °C ... 60 °C (Standard)
Ambient Temperature (Operation)-40 °C ... 70 °C (Extended, see section “Tested successfully: use under extreme ambient conditions” in the data sheet.)
Degree of ProtectionIP20
Air pressure (operation)70 kPa ... 106 kPa (up to 3000 m above sea level)
Air pressure (storage/transport)70 kPa ... 106 kPa (up to 3000 m above sea level)
Ambient temperature (storage/transport)-40 °C ... 85 °C
Permissible humidity (operation)5 % ... 95 % (non-condensing)
Permissible humidity (storage/transport)5 % ... 95 % (non-condensing)

Standards and Regulations

Protection classIII (IEC 61140, EN 61140, VDE 0140-1)

ATEX

IdentificationII 3(1) G Ex ec [ia IIB Ga] IIC T4 GcII (1) D [Ex ia Da] IIIC
CertificateDEMKO 20 ATEX 2370X

IECEx

IdentificationEx ec [ia IIB Ga] IIC T4 Gc[Ex ia Da] IIIC
CertificateIECEx UL 20.0044X

UKCA Ex (UKEX)

IdentificationII 3(1) G Ex ec [ia IIB Ga] IIC T4 GcII (1) D [Ex ia Da] IIIC
CertificateUL22UKEX2508X

Ex data

UL, USA / CanadaInd. Cont. Eq. (E238705) also ListedInd. Cont. Eq. for haz. loc. E196811Install in: Class I, Div. 2, Groups A, B, C, D T4Intrinsically safe outputs for: Class I, Groups C, D; Class II, Groups E, F, G; Class III; [Ex ia] Haz locClass I, Zone 2, AEx ec [ia IIB Ga] IIC T4 Gc[AEx ia Da] IIICEx ec [ia IIB Ga] IIC T4 Gc[Ex ia Da] IIIC

Mounting

Mounting TypeDIN rail mounting

Safety data

Max. output voltage Uo24.8 V
Max. output current Io180 mA
Max. output power Po1116 mW
Safety-related maximum voltage Um250 V
C/IIB, IIIC: Max. external inductivity Lo / Max. external capacitance Co/ 0.86 µF
D/IIA, E, F, G, Class III: Max. external inductivity Lo / Max. external capacitance Co/ 3.05 µF
C/IIB, IIIC: Max. external inductivity Lo / Max. external capacitance Co2.779 mH
D/IIA, E, F, G, Class III: Max. external inductivity Lo / Max. external capacitance Co7.168 mH

Why Proax for Phoenix Contact 1086902?

Proax is an authorized distributor of Phoenix Contact 1086902 and one of Phoenix Contact's largest distributors in North America. Our highly skilled in-house technical team is ready to assist with any technical needs.

Have a question in mind? to help you get the right product as quickly as possible for your project. We're always here to help!

Short Lead Time
Highly Trained Staff
Live Chat
Technical Support
Local Inventory
60+ Years Experience
Additional Information

Pack Size1
Recommended

Not in stock

Request lead time or order—we'll ensure quick delivery

Phoenix Contact Availability