AXL F EX IS AO4 HART XC 1F
Weight
0.378 kg
This product is Not Cancellable/Not Returnable

AXL F EX IS AO4 HART XC 1F - Analog module

Axioline F, Analog output module, Analog outputs: 4 (HART), 0 mA ... 20 mA, 4 mA ... 20 mA, connection technology: 2-conductor, transmission speed in the local bus: 100 Mbps, Extreme conditions version, intrinsically safe, HART functionality, degree of protection: IP20, including bus base module and Axioline F connectors

  • 4 analog output-powered control signals for HART
  • Current range: 4 mA ... 20 mA and 0 mA ... 20 mA
  • Cyclic access to PV, SV, TV, QV, and Loop Current
  • Can be used under extreme ambient conditions
  • Extended temperature range of -40 °C ... +70 °C (see “Tested successfully: use under extreme ambient conditions” in the data sheet)
  • Intrinsically safe analog inputs with connection to Zone 1, Zone 0 or Division 1
Technical Specifications

Dimensions

Width53.6 mm
Height129.9 mm
Depth77.14 mm
Note on dimensionsThe depth applies when a TH 35-7.5 DIN rail is used (in accordance with EN 60715).

Note on application

Note on applicationOnly for industrial use

Utilization restriction

EMC noteEMC: class A product, see manufacturer's declaration in the download area
CCCex noteUse in potentially explosive areas is not permitted in China.

Material specifications

Colortraffic grey A RAL 7042

Axioline F local bus

Number of interfaces2
Connection MethodBus base module
Transmission Speed100 Mbps

Module

Input address area32 Byte (Firmware 1.00)
Input address area40 Byte (Firmware 1.02 or later)
Output address area8 Byte
Required parameter data 15 Byte
Required configuration data 7 Byte

Analog:

Output nameAnalog outputs
Connection MethodPush-in connection
Connection technology2-conductor
Note regarding the connection technologyshielded, twisted pair
Number of Outputs4 (HART)
D/A converter resolution16 bit
Data formatsInline, S7-compatible, standard formatting
Process data update1.9 ms
Current Output Signal0 mA ... 20 mA
Current Output Signal4 mA ... 20 mA

Product properties

Product familyAxioline F
Typeblock modular
Mounting Positionany (no temperature derating)
Scope of deliveryincluding bus base module and Axioline F connectors
Special PropertiesExtreme conditions version
Special Propertiesintrinsically safe
Special PropertiesHART functionality

Insulation characteristics

Overvoltage categoryII (IEC 60664-1, EN 60664-1)
Pollution degree2 (IEC 60664-1, EN 60664-1)

Electrical properties

Maximum power dissipation for nominal condition1.98 W

Potentials: Axioline F local bus supply (UBus)

Supply Voltage5 V DC (via bus base module)
Current drawmax. 60 mA
Current drawtyp. 40 mA

Potentials: Supply for analog modules (UA)

Supply Voltage24 V DC
Supply Voltage Range19.2 V DC ... 30 V DC (including all tolerances, including ripple)
Current drawmax. 150 mA
Protective circuitSurge protection; electronic (35 V, 0.5 s)
Protective circuitReverse polarity protection; Polarity protection diode
Protective circuitTransient protection; Suppressor diode

Electrical isolation/isolation of the voltage ranges

Test voltage: 5 V supply of the local bus (UBus) / 24 V supply (I/Os)500 V AC, 60 Hz, 1 min
Test voltage: 5 V supply of the local bus (UBus) / functional ground500 V AC, 60 Hz, 1 min
Test voltage: 5 V supply of the local bus (UBus) / analog outputs1500 V AC, 60 Hz, 1 min
Test voltage: 24 V supply (I/O) / functional ground500 V AC, 60 Hz, 1 min
Test voltage: 24 V supply (I/O) / analog outputs1500 V AC, 60 Hz, 1 min
Test voltage: Analog outputs/functional ground500 V AC, 60 Hz, 1 min

Connection technology

Connection nameAxioline F connector
Note on the connection methodPlease observe the information provided on conductor cross sections in the “Axioline F: system and installation” user manual.

Conductor connection

Connection MethodPush-in connection
Conductor cross section rigid0.2 mm² ... 1.5 mm²
Conductor cross section flexible0.2 mm² ... 1.5 mm²
Conductor cross section AWG24 ... 16
Stripping length8 mm

Axioline F connector

Connection MethodPush-in connection
Note on the connection methodPlease observe the information provided on conductor cross sections in the “Axioline F: system and installation” user manual.
Conductor cross section, rigid0.2 mm² ... 1.5 mm²
Conductor cross section, flexible0.2 mm² ... 1.5 mm²
Conductor cross section AWG24 ... 16
Stripping length8 mm

Ambient conditions

Ambient Temperature (Operation)-25 °C ... 60 °C (Standard)
Ambient Temperature (Operation)-40 °C ... 70 °C (Extended, see section “Tested successfully: use under extreme ambient conditions” in the data sheet.)
Degree of ProtectionIP20
Air pressure (operation)70 kPa ... 106 kPa (up to 3000 m above sea level)
Air pressure (storage/transport)70 kPa ... 106 kPa (up to 3000 m above sea level)
Ambient temperature (storage/transport)-40 °C ... 85 °C
Permissible humidity (operation)5 % ... 95 % (non-condensing)
Permissible humidity (storage/transport)5 % ... 95 % (non-condensing)

Standards and Regulations

Protection classIII (IEC 61140, EN 61140, VDE 0140-1)

ATEX

IdentificationII 3(1) G Ex ec [ia Ga] IIC T4 GcII (1) D [Ex ia Da] IIIC
CertificateDEMKO 20 ATEX 2370X

IECEx

IdentificationEx ec [ia Ga] IIC T4 Gc[Ex ia Da] IIIC
CertificateIECEx UL 20.0044X

UKCA Ex (UKEX)

IdentificationII 3(1) G Ex ec [ia Ga] IIC T4 GcII (1) D [Ex ia Da] IIIC
CertificateUL22UKEX2508X

UL, USA/Canada

IdentificationcULus
CertificateE238705

UL Ex, USA / Canada

IdentificationClass I, Division 2, Groups A, B, C, D, T4
IdentificationIntrinsically safe outputs for: Class I, Groups A, B, C, D; Class II, Groups E, F, G; Class III; [Ex ia] Haz loc
IdentificationClass I, Zone 2, AEx ec [ia Ga] IIC T4 Gc
Identification[AEx ia Da] IIIC
IdentificationEx ec [ia Ga] IIC T4 Gc
CertificateE196811

CCC / China-Ex

IdentificationEx ec [ia Ga] IIC T4 Gc
Identification[Ex ia Da] IIIC

Ex data

UL, USA / CanadaInd. Cont. Eq. (E238705) also ListedInd. Cont. Eq. for haz. loc. E196811Install in: Class I, Div. 2, Groups A, B, C, D T4Intrinsically safe outputs for: Class I, Groups A, B, C, D; Class II, Groups E, F, G; Class III; [Ex ia] Haz locClass I, Zone 2, AEx ec [ia Ga] IIC T4 Gc[AEx ia Da] IIICEx ec [ia Ga] IIC T4 Gc[Ex ia Da] IIIC

Mounting

Mounting TypeDIN rail mounting
Mounting Positionany (no temperature derating)

Safety data

Max. output voltage Uo24.8 V
Max. output current Io86.7 mA
Max. output power Po538 mW
Safety-related maximum voltage Um250 V
A, B / IIC: Max. external inductivity Lo / Max. external capacitance Co4.1 mH / 0.112 µF
C/IIB, IIIC: Max. external inductivity Lo / Max. external capacitance Co18.29 mH / 0.859 µF
D/IIA, E, F, G, Class III: Max. external inductivity Lo / Max. external capacitance Co37.21 mH / 3.049 µF

Why Proax for Phoenix Contact 1087081?

Proax is an authorized distributor of Phoenix Contact 1087081 and one of Phoenix Contact's largest distributors in North America. Our highly skilled in-house technical team is ready to assist with any technical needs.

Have a question in mind? to help you get the right product as quickly as possible for your project. We're always here to help!

Short Lead Time
Highly Trained Staff
Live Chat
Technical Support
Local Inventory
60+ Years Experience
Additional Information

Pack Size1
Recommended

Not in stock

Request lead time or order—we'll ensure quick delivery

Phoenix Contact Availability