SKU
MPN
AXL F EX IS AO4 HART XC 1F
Weight
0.378 kg
This product is Not Cancellable/Not Returnable
AXL F EX IS AO4 HART XC 1F - Analog module
Axioline F, Analog output module, Analog outputs: 4 (HART), 0 mA ... 20 mA, 4 mA ... 20 mA, connection technology: 2-conductor, transmission speed in the local bus: 100 Mbps, Extreme conditions version, intrinsically safe, HART functionality, degree of protection: IP20, including bus base module and Axioline F connectors
- 4 analog output-powered control signals for HART
- Current range: 4 mA ... 20 mA and 0 mA ... 20 mA
- Cyclic access to PV, SV, TV, QV, and Loop Current
- Can be used under extreme ambient conditions
- Extended temperature range of -40 °C ... +70 °C (see “Tested successfully: use under extreme ambient conditions” in the data sheet)
- Intrinsically safe analog inputs with connection to Zone 1, Zone 0 or Division 1
Documents
Technical Specifications
Dimensions
Width | 53.6 mm |
Height | 129.9 mm |
Depth | 77.14 mm |
Note on dimensions | The depth applies when a TH 35-7.5 DIN rail is used (in accordance with EN 60715). |
Note on application
Note on application | Only for industrial use |
Utilization restriction
EMC note | EMC: class A product, see manufacturer's declaration in the download area |
CCCex note | Use in potentially explosive areas is not permitted in China. |
Material specifications
Color | traffic grey A RAL 7042 |
Axioline F local bus
Number of interfaces | 2 |
Connection Method | Bus base module |
Transmission Speed | 100 Mbps |
Module
Input address area | 32 Byte (Firmware 1.00) |
Input address area | 40 Byte (Firmware 1.02 or later) |
Output address area | 8 Byte |
Required parameter data | 15 Byte |
Required configuration data | 7 Byte |
Analog:
Output name | Analog outputs |
Connection Method | Push-in connection |
Connection technology | 2-conductor |
Note regarding the connection technology | shielded, twisted pair |
Number of Outputs | 4 (HART) |
D/A converter resolution | 16 bit |
Data formats | Inline, S7-compatible, standard formatting |
Process data update | 1.9 ms |
Current Output Signal | 0 mA ... 20 mA |
Current Output Signal | 4 mA ... 20 mA |
Product properties
Product family | Axioline F |
Type | block modular |
Mounting Position | any (no temperature derating) |
Scope of delivery | including bus base module and Axioline F connectors |
Special Properties | Extreme conditions version |
Special Properties | intrinsically safe |
Special Properties | HART functionality |
Insulation characteristics
Overvoltage category | II (IEC 60664-1, EN 60664-1) |
Pollution degree | 2 (IEC 60664-1, EN 60664-1) |
Electrical properties
Maximum power dissipation for nominal condition | 1.98 W |
Potentials: Axioline F local bus supply (UBus)
Supply Voltage | 5 V DC (via bus base module) |
Current draw | max. 60 mA |
Current draw | typ. 40 mA |
Potentials: Supply for analog modules (UA)
Supply Voltage | 24 V DC |
Supply Voltage Range | 19.2 V DC ... 30 V DC (including all tolerances, including ripple) |
Current draw | max. 150 mA |
Protective circuit | Surge protection; electronic (35 V, 0.5 s) |
Protective circuit | Reverse polarity protection; Polarity protection diode |
Protective circuit | Transient protection; Suppressor diode |
Electrical isolation/isolation of the voltage ranges
Test voltage: 5 V supply of the local bus (UBus) / 24 V supply (I/Os) | 500 V AC, 60 Hz, 1 min |
Test voltage: 5 V supply of the local bus (UBus) / functional ground | 500 V AC, 60 Hz, 1 min |
Test voltage: 5 V supply of the local bus (UBus) / analog outputs | 1500 V AC, 60 Hz, 1 min |
Test voltage: 24 V supply (I/O) / functional ground | 500 V AC, 60 Hz, 1 min |
Test voltage: 24 V supply (I/O) / analog outputs | 1500 V AC, 60 Hz, 1 min |
Test voltage: Analog outputs/functional ground | 500 V AC, 60 Hz, 1 min |
Connection technology
Connection name | Axioline F connector |
Note on the connection method | Please observe the information provided on conductor cross sections in the “Axioline F: system and installation” user manual. |
Conductor connection
Connection Method | Push-in connection |
Conductor cross section rigid | 0.2 mm² ... 1.5 mm² |
Conductor cross section flexible | 0.2 mm² ... 1.5 mm² |
Conductor cross section AWG | 24 ... 16 |
Stripping length | 8 mm |
Axioline F connector
Connection Method | Push-in connection |
Note on the connection method | Please observe the information provided on conductor cross sections in the “Axioline F: system and installation” user manual. |
Conductor cross section, rigid | 0.2 mm² ... 1.5 mm² |
Conductor cross section, flexible | 0.2 mm² ... 1.5 mm² |
Conductor cross section AWG | 24 ... 16 |
Stripping length | 8 mm |
Ambient conditions
Ambient Temperature (Operation) | -25 °C ... 60 °C (Standard) |
Ambient Temperature (Operation) | -40 °C ... 70 °C (Extended, see section “Tested successfully: use under extreme ambient conditions” in the data sheet.) |
Degree of Protection | IP20 |
Air pressure (operation) | 70 kPa ... 106 kPa (up to 3000 m above sea level) |
Air pressure (storage/transport) | 70 kPa ... 106 kPa (up to 3000 m above sea level) |
Ambient temperature (storage/transport) | -40 °C ... 85 °C |
Permissible humidity (operation) | 5 % ... 95 % (non-condensing) |
Permissible humidity (storage/transport) | 5 % ... 95 % (non-condensing) |
Standards and Regulations
Protection class | III (IEC 61140, EN 61140, VDE 0140-1) |
ATEX
Identification | II 3(1) G Ex ec [ia Ga] IIC T4 GcII (1) D [Ex ia Da] IIIC |
Certificate | DEMKO 20 ATEX 2370X |
IECEx
Identification | Ex ec [ia Ga] IIC T4 Gc[Ex ia Da] IIIC |
Certificate | IECEx UL 20.0044X |
UKCA Ex (UKEX)
Identification | II 3(1) G Ex ec [ia Ga] IIC T4 GcII (1) D [Ex ia Da] IIIC |
Certificate | UL22UKEX2508X |
UL, USA/Canada
Identification | cULus |
Certificate | E238705 |
UL Ex, USA / Canada
Identification | Class I, Division 2, Groups A, B, C, D, T4 |
Identification | Intrinsically safe outputs for: Class I, Groups A, B, C, D; Class II, Groups E, F, G; Class III; [Ex ia] Haz loc |
Identification | Class I, Zone 2, AEx ec [ia Ga] IIC T4 Gc |
Identification | [AEx ia Da] IIIC |
Identification | Ex ec [ia Ga] IIC T4 Gc |
Certificate | E196811 |
CCC / China-Ex
Identification | Ex ec [ia Ga] IIC T4 Gc |
Identification | [Ex ia Da] IIIC |
Ex data
UL, USA / Canada | Ind. Cont. Eq. (E238705) also ListedInd. Cont. Eq. for haz. loc. E196811Install in: Class I, Div. 2, Groups A, B, C, D T4Intrinsically safe outputs for: Class I, Groups A, B, C, D; Class II, Groups E, F, G; Class III; [Ex ia] Haz locClass I, Zone 2, AEx ec [ia Ga] IIC T4 Gc[AEx ia Da] IIICEx ec [ia Ga] IIC T4 Gc[Ex ia Da] IIIC |
Mounting
Mounting Type | DIN rail mounting |
Mounting Position | any (no temperature derating) |
Safety data
Max. output voltage Uo | 24.8 V |
Max. output current Io | 86.7 mA |
Max. output power Po | 538 mW |
Safety-related maximum voltage Um | 250 V |
A, B / IIC: Max. external inductivity Lo / Max. external capacitance Co | 4.1 mH / 0.112 µF |
C/IIB, IIIC: Max. external inductivity Lo / Max. external capacitance Co | 18.29 mH / 0.859 µF |
D/IIA, E, F, G, Class III: Max. external inductivity Lo / Max. external capacitance Co | 37.21 mH / 3.049 µF |
Why Proax for Phoenix Contact 1087081?
Proax is an authorized distributor of Phoenix Contact 1087081 and one of Phoenix Contact's largest distributors in North America. Our highly skilled in-house technical team is ready to assist with any technical needs.
Have a question in mind? to help you get the right product as quickly as possible for your project. We're always here to help!
Short Lead Time
Highly Trained Staff
Live Chat
Technical Support
Local Inventory
60+ Years Experience
Additional Information
Pack Size | 1 |
Recommended
- Axioline F, Analog input module, Active analog inputs: 8 (HART), 4 mA ... 20 mA, connection technology: 2-conductor, transmission speed in the local bus: 100 Mbps, Extreme conditions version, intrinsically safe, HART functionality, degree of protection: IP20, including bus base module and Axioline F connectors
- AXL F EX IS DO4 SD 21-60 XC 1F - Axioline F, Digital output module, Digital outputs: 4, 21 V, connection technology: 2-conductor, Extreme conditions version, Intrinsically safe, Solenoid drive, transmission speed in the local bus: 100 Mbps, degree of protection: IP20, including bus base module and Axioline F connectors
- AXL F EX IS DI16 NAM XC 1F - Axioline F, Digital input module, Digital inputs: 16 (NAMUR), 8 V DC, connection technology: 2-conductor, Extreme conditions version, Intrinsically safe, transmission speed in the local bus: 100 Mbps, degree of protection: IP20, including bus base module and Axioline F connectors