Proax

Currency
0 Items
proax logo
Cart
Phoenix ContactOfficial Distributor

By Phoenix Contact

SKU
MPN
PT 4-HESILED 24 (5X20) BU/BU
Weight
0.013 kg
Series PT

PT 4-HESILED 24 (5X20) BU/BU - Fuse modular terminal block

Fuse modular terminal block, fuse type: Glass / ceramics / ..., fuse type: G / 5 x 20, nom. voltage: 24 V, nominal current: 6.3 A, connection method: Push-in connection, Rated cross section: 1 mm2, cross section:  0.2 mm2- 6 mm2, mounting type: NS 35/7,5, NS 35/15, color: blue

  • In addition to the testing option in the double function shaft, all terminal blocks provide an additional test pick-off
  • The compact design and front connection enable wiring in a confined space
  • The Push-in connection terminal blocks are characterized by the system features of the CLIPLINE complete system and by easy and tool-free wiring of conductors with ferrules or solid conductors
  • Tested for railway applications
Technical Specifications

Notes

GeneralThe current is determined by the fuse used, the voltage by the selected LED.If the fuse is faulty, the downstream circuit will not be disconnected.

Product properties

Area of applicationRailway industry
Area of applicationMachine building
Area of applicationPlant engineering
Number of Connections2
Number of rows1
Potentials1

Insulation characteristics

Overvoltage categoryIII
Degree of pollution3

Electrical properties

Fuse typeGlass / ceramics / ...
Rated surge voltage4 kV
Maximum power dissipation for nominal condition1.02 W
FuseG / 5 x 20
LED voltage range12 V AC/DC ... 30 V AC/DC
LED current range0.31 mA ... 0.95 mA
Maximum power dissipationmax. 1.6 W (with single arrangement of the fuse terminal block in the event of overload)
Maximum power dissipationmax. 1.6 W (With interconnected arrangement of several fuse terminal blocks in the event of overload)
Maximum power dissipationmax. 4 W (with single arrangement of the fuse terminal block in the event of a short-circuit)
Maximum power dissipationmax. 2.5 W (With interconnected arrangement of several fuse terminal blocks in the event of a short-circuit)

Input data

LED voltage range12 V AC/DC ... 30 V AC/DC

Connection data

Number of connections per level2
Nominal cross section4 mm²
Stripping length10 mm ... 12 mm
Internal cylindrical gageA4
Connection in acc. with standardIEC 60947-7-3
Conductor cross section rigid0.2 mm² ... 6 mm²
Cross section AWG24 ... 10 (converted acc. to IEC)
Conductor cross section flexible0.2 mm² ... 6 mm²
Conductor cross section, flexible [AWG]24 ... 10 (converted acc. to IEC)
Conductor cross-section flexible (ferrule without plastic sleeve)0.25 mm² ... 4 mm²
Flexible conductor cross section (ferrule with plastic sleeve)0.25 mm² ... 4 mm²
2 conductors with the same cross section, flexible, with TWIN ferrule with plastic sleeve0.5 mm² ... 1 mm²
Nominal Current6.3 A
Maximum Load Current6.3 A (with 6 mm² conductor cross section, rigid)
Nominal Voltage24 V
Nominal cross section1 mm²

Connection cross sections directly pluggable

Conductor cross section rigid0.5 mm² ... 6 mm²
Conductor cross-section flexible (ferrule without plastic sleeve)0.5 mm² ... 4 mm²
Flexible conductor cross section (ferrule with plastic sleeve)0.5 mm² ... 4 mm²

Dimensions

Width6.2 mm
End cover width2.2 mm
Height56 mm
Depth63.4 mm
Depth on NS 35/7,562.5 mm
Depth on NS 35/1570 mm

Material specifications

Colorblue
Flammability rating according to UL 94V0
Insulating material groupI
Insulating materialPA
Static insulating material application in cold-60 °C
Temperature index of insulation material (DIN EN 60216-1 (VDE 0304-21))130 °C
Relative insulation material temperature index (Elec., UL 746 B)130 °C
Fire protection for rail vehicles (DIN EN 45545-2) R22HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R23HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R24HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R26HL 1 - HL 3
Calorimetric heat release NFPA 130 (ASTM E 1354)28 MJ/kg
Surface flammability NFPA 130 (ASTM E 162)passed
Specific optical density of smoke NFPA 130 (ASTM E 662)passed
Smoke gas toxicity NFPA 130 (SMP 800C)passed

Mechanical data

Open side panelYes

Ambient conditions

Ambient Temperature (Operation)-60 °C ... 110 °C (Operating temperature range incl. self-heating; for max. short-term operating temperature, see RTI Elec.)
Ambient temperature (storage/transport)-25 °C ... 60 °C (for a short time, not exceeding 24 h, -60 °C to +70 °C)
Ambient temperature (assembly)-5 °C ... 70 °C
Ambient temperature (actuation)-5 °C ... 70 °C
Permissible humidity (operation)20 % ... 90 %
Permissible humidity (storage/transport)30 % ... 70 %

Standards and Regulations

Connection in acc. with standardIEC 60947-7-3

Mounting

Mounting TypeNS 35/7,5
Mounting TypeNS 35/15
Accessories

Why Proax for Phoenix Contact 3211905?

Proax is an authorized distributor of Phoenix Contact 3211905 and one of Phoenix Contact's largest distributors in North America. Our highly skilled in-house technical team is ready to assist with any technical needs.

Have a question in mind? to help you get the right product as quickly as possible for your project. We're always here to help!

Short Lead Time
Highly Trained Staff
Live Chat
Technical Support
Local Inventory
60+ Years Experience
Additional Information

Pack Size50
Recommended
Sold in quantities of 50

Not in stock

Request lead time or order—we'll ensure quick delivery

Phoenix Contact Availability