MPN
FL MC EF 660 SCRJ
Weight
0.173 kg
Series FL-MC-EF

FL MC EF 660 SCRJ - FO converters

FO converter, for converting 100Base-T to polymer and PCF fiber (660 nm), SC-RJ FO connection (PROFINET standard), can be mounted on a DIN rail, 24 V DC supply

  • Link fault pass through (LFPT) function for easy connection monitoring
  • Very low delay times
  • Mounting on a DIN rail
  • Backplane bus contact, enabling alternative or redundant 24 V power supply
Technical Specifications

Product properties

MTTF929 Years (SN 29500 standard, temperature 25°C, operating cycle 21%)
MTTF461 Years (SN 29500 standard, temperature 40°C, operating cycle 34.25%)
MTTF204 Years (SN 29500 standard, temperature 40°C, operating cycle 100%)

Electrical properties

Electrical isolationVCC // Ethernet
Maximum power dissipation for nominal condition2.4 W
Test voltage data interface/power supply1.5 kVrms (50 Hz, 1 min.)
Test voltage data interface/power supply1500 V

Supply

Supply Voltage Range18 V DC ... 32 V DC (via pluggable COMBICON screw terminal block)
Supply Voltage Range18 V DC ... 32 V DC (as an alternative or redundant, via backplane bus contact and system current supply)
Typical current consumption≤ 85 mA (24 V DC)
Max. current consumption100 mA (24 V DC)
Protective circuitReverse polarity protection

Switching

Output nameRelay output
Number of Outputs2
Contact switching typeN/O contact
Maximum Switching Voltage60 V AC/DC
Max. switching current1 A

Supply

Connection MethodPlug-in screw terminal block (COMBICON), redundancy possible
Tightening torque0.56 Nm ... 0.79 Nm

Interfaces

SignalEthernet
SignalPROFINET

Data: optical FO

Transmit capacity, minimummin. -8 dBm (980/1000 µm, static)
Transmit capacity, minimummin. -19 dBm (200/230 µm, static)
Transmit capacity, maximummax. -2 dBm (980/1000 µm, static)
Transmit capacity, maximummax. -11 dBm (200/230 µm, static)
Transmission length incl. 3 dB system reserve50 m (Polymer fiber with F-P 980/1000 230 dB/km)
Transmission length incl. 3 dB system reserve100 m (PCF fiber with F-K 200/230 8 dB/km)
Connection MethodSC-RJ
Wavelength660 nm
Minimum receiver sensitivity-23 dBm (980/1000 µm, static)
Minimum receiver sensitivity-26.8 dBm (200/230 µm, static)
Transmission mediumPolymer fiber
Transmission mediumPCF fiber

Data: Ethernet interface, 100Base-T(X) in accordance with IEEE 802.3

Transmission Speed100 Mbps
Connection MethodRJ45 jack, shielded
No. of channels1
Transmission length100 m (shielded twisted pair)
Transmission mediumCopper
Link throughLink fault pass through

Dimensions

Width22.5 mm
Height99 mm
Depth114.5 mm

Material specifications

Color (Housing)green (RAL 6021)
Material (Housing)PA V0

FO cable

Fiber types980/1000 µm
Fiber types200/230 µm
Fiber typesPolymer fiber
Fiber typesPCF fiber

Ambient conditions

Degree of ProtectionIP20
Ambient Temperature (Operation)-40 °C ... 60 °C
Ambient temperature (storage/transport)-40 °C ... 70 °C
Altitude≤ 5000 m (For restrictions, see the manufacturer's declaration for altitude operation)
Permissible humidity (operation)10 % ... 95 % (non-condensing)

CE

CertificateCE-compliant

Corrosive gas test

IdentificationISA-S71.04-1985 G3 Harsh Group A

EMC data

Electromagnetic compatibilityConformance with EMC Directive 2014/30/EU
Conducted noise emissionEN 61000-6-3 Class B, domain of use: residential and small commercial

Electrostatic discharge

Standards/regulationsEN 61000-4-2
Contact discharge± 6 kV (Test Level 3)
Discharge in air± 8 kV (Test Level 3)
Indirect discharge± 6 kV
CommentsCriterion B

Electromagnetic HF field

Standards/regulationsEN 61000-4-3
Frequency Range80 MHz ... 3 GHz (Test Level 3)
Field intensity10 V/m
CommentsCriterion A

Fast transients (burst)

Standards/regulationsEN 61000-4-4
Input± 2.2 kV (1 minute)
Signal± 2.2 kV (1 minute)
CommentsCriterion B

Surge current load (surge)

Standards/regulationsEN 61000-4-5
Input± 0.5 kV (Supply)
Signal± 1 kV (Shielded cable)
CommentsCriterion B

Conducted interference

Standards/regulationsEN 61000-4-6
Frequency Range0.15 MHz ... 80 MHz
CommentsCriterion A
Voltage10 V

Emitted interference

Standards/regulationsEN 61000-6-4
CommentsClass A, industrial applications

Criteria

Criterion ANormal operating behavior within the specified limits.
Criterion BTemporary impairment to operational behavior that is corrected by the device itself.

Standards and Regulations

Free from substances that could impair the application of coatingin accordance with VW-AUDI-Seat central standard P-VW 3.10.7 57 65 0

Mounting

Mounting TypeDIN rail mounting
Accessories

Why Proax for Phoenix Contact 2702944?

Proax is an authorized distributor of Phoenix Contact 2702944 and one of Phoenix Contact's largest distributors in North America. Our highly skilled in-house technical team is ready to assist with any technical needs.

Have a question in mind? to help you get the right product as quickly as possible for your project. We're always here to help!

Short Lead Time
Highly Trained Staff
Live Chat
Technical Support
Local Inventory
60+ Years Experience
Additional Information

Pack Size1
Recommended

Available for order

Phoenix Contact Availability