2902856
SKU
PHX2902856
MPN
FL MC EF 1300 SM SC
Weight
0.172 kg
Series FL-MC-EF
FL MC EF 1300 SM SC - FO converters
FO converter with SC duplex fiber optic connection (1300 nm), for converting 10/100Base-T(X) to single mode fiberglass (9/125 µm). Auto negotiation and auto MDI(X) function. Comprehensive link diagnostics. DIN-rail mountable, 18 ... 30 V DC supply.
- Transmission ranges up to 36 km
- Auto negotiation
- Auto MDI/MDI-X switch-over
- Link fault pass through (LFPT) and far end fault (FEF) functions for easy connection monitoring
- 10/100 Mbps
- Shipbuilding approval in accordance with DNV GL
Technical Specifications
Utilization restriction
| EMC note | EMC: class A product, see manufacturer's declaration in the download area |
| CCCex note | Use in potentially explosive areas is not permitted in China. |
Product properties
| MTTF | 1400 Years (SN 29500 standard, temperature 25°C, operating cycle 21%) |
| MTTF | 599 Years (SN 29500 standard, temperature 40°C, operating cycle 34.25%) |
| MTTF | 101 Years (SN 29500 standard, temperature 40°C, operating cycle 100%) |
| MTBF | 284 Years (Telcordia standard, 25°C temperature, 21% operating cycle (5 days a week, 8 hours a day)) |
| MTBF | 74 Years (Telcordia standard, 40°C temperature, 34.25% operating cycle (5 days a week, 12 hours a day)) |
| Signal delay | ± 1.3 µs (Store and Forward mode, 10/100 Mbps, depending on the frame size) |
Functionality
| Basic Functions | Store-and-forward media converter |
Electrical properties
| Electrical isolation | according to IEEE 802.3 |
| Electrical isolation | VCC // FE // Ethernet |
| Maximum power dissipation for nominal condition | 2.4 W |
| Test voltage data interface/power supply | 0.5 kVrms (50 Hz, 1 min.) |
Supply
| Supply Voltage Range | 18 V DC ... 30 V DC (Screw connection) |
| Supply Voltage Range | 18 V DC ... 30 V DC (as an alternative or redundant, via backplane bus contact and system current supply) |
| Typical current consumption | < 100 mA (24 V DC) |
| Protective circuit | Reverse polarity protection |
| Connection Method | Plug-in screw terminal block (COMBICON), redundancy possible |
| Single conductor/terminal point, rigid | 0.2 mm² ... 2.5 mm² |
| Single-wire/terminal point, flexible | 0.2 mm² ... 2.5 mm² |
| Conductor cross section, flexible [AWG] | 24 ... 14 |
| Stripping length | 7.00 mm |
| Tightening torque | 0.56 Nm ... 0.79 Nm |
Interfaces
| Signal | Ethernet |
| Basic Functions | Store-and-forward media converter |
Data: optical FO
| Transmit capacity, minimum | ≥ -15 dBm ((9/125 µm) dynamic in link mode (average)) |
| Transmit capacity, maximum | ≤ -8 dBm ((9/125 µm) dynamic in link mode (average)) |
| Transmission length incl. 3 dB system reserve | 36 km (F-E 9/125 0.36 dB/km) |
| Transmission length incl. 3 dB system reserve | 32 km (F-E 9/125 0.4 dB/km) |
| Transmission length incl. 3 dB system reserve | 26 km (F-E 9/125 0.5 dB/km) |
| Connection Method | SC duplex |
| Wavelength | 1300 nm |
| Minimum receiver sensitivity | -31 dBm (dynamic in link mode (average)) |
| Maximum receiver sensitivity | -7 dBm (dynamic in link mode (average)) |
| Transmission medium | Single-mode fiberglass |
Data: Ethernet interface, 10/100Base-T(X) in accordance with IEEE 802.3
| Transmission Speed | 10/100 Mbps |
| Connection Method | RJ45 jack, shielded |
| No. of channels | 1 |
| Transmission length | 100 m (shielded twisted pair) |
| Transmission medium | Copper |
| Signal LEDs | Activity, link status, 10/100 Mbps |
| Auto-negotiation modes | Auto |
| Link through | Link fault pass through |
| MDI-/MDI-X switchover | Auto-MDI(X) |
Dimensions
| Width | 22.5 mm |
| Height | 99 mm |
| Depth | 114.5 mm |
Material specifications
| Color (Housing) | green (RAL 6021) |
| Material (Housing) | PA 6.6-FR |
FO cable
| Fiber types | 50/125 µm |
| Fiber types | 62.5/125 µm |
| Fiber types | Fiberglass |
Ambient conditions
| Degree of Protection | IP20 |
| Ambient Temperature (Operation) | -40 °C ... 65 °C |
| Ambient temperature (storage/transport) | -40 °C ... 85 °C |
| Altitude | ≤ 5000 m (For restrictions, see the manufacturer's declaration for altitude operation) |
| Altitude | ≤ 2000 m (in acc. with UL) |
| Permissible humidity (operation) | 5 % ... 95 % (non-condensing) |
| Permissible humidity (storage/transport) | 5 % ... 95 % (non-condensing) |
CE
| Certificate | CE-compliant |
ATEX
| Identification | II 3 G Ex nA IIC T4 Gc X |
| Note | Please follow the special installation instructions in the documentation! |
UL, USA/Canada
| Identification | 508 Listed |
| Identification | Class I, Zone 2, AEx nA IIC T4 |
| Identification | Class I, Zone 2, Ex nA IIC T4 Gc X |
| Identification | Class I, Div. 2, Groups A, B, C, D |
Corrosive gas test
| Identification | ISA-S71.04-1985 G3 Harsh Group A |
Shipbuilding
| Identification | DNV GL |
DNV GL data
| Temperature | B |
| Humidity | A |
| Vibration | A |
| EMC | B |
| Enclosure | Required protection according to the Rules shall be provided upon installation on board |
EMC data
| Electromagnetic compatibility | Conformance with EMC Directive 2014/30/EU |
Electrostatic discharge
| Standards/regulations | EN 61000-4-2 |
| Contact discharge | ± 6 kV (Test Level 3) |
| Discharge in air | ± 8 kV (Test Level 3) |
| Indirect discharge | ± 6 kV |
| Comments | Criterion B |
Electromagnetic HF field
| Standards/regulations | EN 61000-4-3 |
| Frequency Range | 80 MHz ... 3 GHz (Test Level 3) |
| Field intensity | 10 V/m |
| Comments | Criterion A |
Fast transients (burst)
| Standards/regulations | EN 61000-4-4 |
| Input | ± 2 kV (Test Level 3) |
| Signal | ± 2 kV (Test Level 3) |
| Comments | Criterion B |
Surge current load (surge)
| Standards/regulations | EN 61000-4-5 |
| Input | ± 0.5 kV (DC supply) |
| Signal | ± 1 kV (Data line, asymmetrical) |
| Comments | Criterion B |
Conducted interference
| Standards/regulations | EN 61000-4-6 |
| Frequency Range | 0.15 MHz ... 80 MHz |
| Comments | Criterion A |
| Voltage | 10 V |
Emitted interference
| Standards/regulations | EN 55032 |
| Comments | Class A, industrial applications |
Criteria
| Criterion A | Normal operating behavior within the specified limits. |
| Criterion B | Temporary impairment to operational behavior that is corrected by the device itself. |
Standards and Regulations
| Free from substances that could impair the application of coating | in accordance with VW-AUDI-Seat central standard P-VW 3.10.7 57 65 0 |
| Electrical isolation | according to IEEE 802.3 |
Mounting
| Mounting Type | DIN rail mounting |
Accessories
ME 22,5 TBUS 1,5/ 5-ST-3,81 GN - DIN rail connector, color: green, nominal current: 8 A (parallel contacts), rated voltage (III/2): 125 V, number of positions: 5, product range: TBUS5-22,5.., pitch: 3.81 mm, mounting: DIN rail mounting, locking: without, mounting: without, type of packaging: packed in cardboard, Item with gold-plated contacts, bus connectors for connecting with electronics housings, 5 parallel contacts
Why Proax for Phoenix Contact 2902856?
Proax is an authorized distributor of Phoenix Contact 2902856 and one of Phoenix Contact's largest distributors in North America. Our highly skilled in-house technical team is ready to assist with any technical needs.
Have a question in mind? to help you get the right product as quickly as possible for your project. We're always here to help!
Short Lead Time
Highly Trained Staff
Live Chat
Technical Support
Local Inventory
60+ Years Experience
Additional Information