Official Distributor
SKU
MPN
FL MC 10/100BASE-T/FO-660
Weight
0.195 kg
This product is Not Cancellable/Not Returnable
Series FL-MC
FL MC 10/100BASE-T/FO-660 - FO converters
FO converter, for converting 10/100Base-T to polymer and PCF fiber, (660 nm), SC-RJ FO connection (PROFINET standard), rail-mountable, supply 24 V DC
- Choice between local or transparent auto negotiation function for maximum transmission capacity
- Link through function for easy connection monitoring. The availability of the connected cable connection and devices is monitored and indicated.
- Backplane bus contact, enabling alternative or redundant 24 V power supply
Technical Specifications
Utilization restriction
EMC note | EMC: class A product, see manufacturer's declaration in the download area |
Product properties
MTTF | 885 Years (SN 29500 standard, temperature 25°C, operating cycle 21%) |
MTTF | 446 Years (SN 29500 standard, temperature 40°C, operating cycle 34.25%) |
MTTF | 202 Years (SN 29500 standard, temperature 40°C, operating cycle 100%) |
MTBF | 564 Years (Telcordia standard, 25°C temperature, 21% operating cycle (5 days a week, 8 hours a day)) |
MTBF | 136 Years (Telcordia standard, 40°C temperature, 34.25% operating cycle (5 days a week, 12 hours a day)) |
Electrical properties
Electrical isolation | VCC // Ethernet |
Maximum power dissipation for nominal condition | 2.4 W |
Test voltage data interface/power supply | 1.5 kVrms (50 Hz, 1 min.) |
Test voltage data interface/power supply | 1500 V |
Supply
Supply Voltage Range | 18 V DC ... 30 V DC (via pluggable COMBICON screw terminal block) |
Supply Voltage Range | 23 V DC ... 25 V DC (as an alternative or redundant, via backplane bus contact and system current supply) |
Nominal Supply Voltage | 24 V DC |
Typical current consumption | ≤ 100 mA (24 V DC) |
Protective circuit | Reverse polarity protection |
Function
Status and diagnostic indicators | UL (communications power, green) |
Switching
Output name | Relay output |
Number of Outputs | 2 |
Contact switching type | N/O contact |
Maximum Switching Voltage | 60 V AC/DC |
Max. switching current | 1 A |
Supply
Connection Method | Plug-in screw terminal block (COMBICON), redundancy possible |
Tightening torque | 0.56 Nm ... 0.79 Nm |
Interfaces
Signal | Ethernet |
Signal | PROFINET |
Data: optical FO
Transmit capacity, minimum | min. -8 dBm (980/1000 µm, static) |
Transmit capacity, minimum | min. -19 dBm (200/230 µm, static) |
Transmit capacity, maximum | max. -2 dBm (980/1000 µm, static) |
Transmit capacity, maximum | max. -11 dBm (200/230 µm, static) |
Transmission length incl. 3 dB system reserve | 70 m (Polymer fiber with F-P 980/1000 230 dB/km at 10 Mbps) |
Transmission length incl. 3 dB system reserve | 300 m (PCF fiber with F-K 200/230 8 dB/km at 10 Mbps) |
Transmission length incl. 3 dB system reserve | 50 m (Polymer fiber with F-P 980/1000 230 dB/km at 100 Mbps) |
Transmission length incl. 3 dB system reserve | 100 m (PCF fiber with F-K 200/230 8 dB/km at 100 Mbps) |
Transmission length incl. 3 dB system reserve | 300 m (HCS GI fiber with F-GK 200/230 at 100 Mbps) |
Transmission length incl. 3 dB system reserve | 400 m (HCS GI fiber with F-GK 200/230 at 10 Mbps) |
Connection Method | SC-RJ |
Wavelength | 660 nm |
Minimum receiver sensitivity | min. -23 dBm (980/1000 µm, static) |
Minimum receiver sensitivity | min. -26.8 dBm (200/230 µm, static) |
Transmission medium | Polymer fiber |
Transmission medium | PCF fiber |
Data: Ethernet interface, 10/100Base-T(X) in accordance with IEEE 802.3
Transmission Speed | 10/100 Mbps |
Connection Method | RJ45 jack, shielded |
No. of channels | 1 |
Transmission length | 100 m (shielded twisted pair) |
Transmission medium | Copper |
Signal LEDs | Activity (yellow), link status (green, UL flashing), 100 Mbps (green) |
Auto-negotiation modes | optionally transparent via TP and FO (default) or locally on TP |
Link through | Link down is automatically forwarded to the second connection |
MDI-/MDI-X switchover | Built-in switch for line (1:1) and crossover connection |
Dimensions
Width | 22.5 mm |
Height | 99 mm |
Depth | 114.5 mm |
Material specifications
Color (Housing) | green (RAL 6021) |
Material (Housing) | PA V0 |
FO cable
Fiber types | 980/1000 µm |
Fiber types | 200/230 µm |
Fiber types | Polymer fiber |
Fiber types | PCF fiber |
Ambient conditions
Degree of Protection | IP20 |
Ambient Temperature (Operation) | -20 °C ... 60 °C |
Ambient temperature (storage/transport) | -30 °C ... 70 °C |
Altitude | ≤ 5000 m (For restrictions, see the manufacturer's declaration for altitude operation) |
Permissible humidity (operation) | 10 % ... 95 % (non-condensing) |
CE
Certificate | CE-compliant |
ATEX
Identification | II 3 G Ex nA nC IIC T4 Gc X |
Note | Please follow the special installation instructions in the documentation! |
UL, USA/Canada
Identification | 508 Recognized |
Corrosive gas test
Identification | ISA-S71.04-1985 G3 Harsh Group A |
EMC data
Noise immunity | EN 61000-6-2:2005 |
Electromagnetic compatibility | Conformance with EMC Directive 2014/30/EU |
Noise emission | EN 50081-2 |
Electrostatic discharge
Standards/regulations | EN 61000-4-2 |
Contact discharge | ± 6 kV (Test Level 3) |
Discharge in air | ± 8 kV (Test Level 3) |
Comments | Criterion B |
Electromagnetic HF field
Standards/regulations | EN 61000-4-3 |
Frequency Range | 80 MHz ... 3 GHz (Test Level 3) |
Field intensity | 10 V/m |
Comments | Criterion A |
Fast transients (burst)
Standards/regulations | EN 61000-4-4 |
Input | ± 4 kV (Test Level 3) |
Signal | ± 2 kV (Test Level 3) |
Comments | Criterion B |
Surge current load (surge)
Standards/regulations | EN 61000-4-5 |
Input | ± 0.5 kV (DC supply) |
Signal | ± 2 kV |
Comments | Criterion B |
Conducted interference
Standards/regulations | EN 61000-4-6 |
Frequency Range | 0.15 MHz ... 80 MHz |
Comments | Criterion A |
Voltage | 10 V |
Emitted interference
Standards/regulations | EN 55011 |
Comments | Class A, industrial applications |
Standards and Regulations
Free from substances that could impair the application of coating | in accordance with VW-AUDI-Seat central standard P-VW 3.10.7 57 65 0 |
Mounting
Mounting Type | DIN rail mounting |
Accessories
- Kit de confection de câbles HCS pour connecteur SC-RJ à montage rapide comprenant un couteau et une pince à dénuder, des ciseaux pour fil aramide, une pince à fibre, un microscope, un outil à entailler les fibres HCS standard et les fibres HCS-GI, deux connecteurs mâles SC-RJ pour fibres HCS standard ainsi que la documentation
- 2707437 - DIN rail connector, color: green, nominal current: 8 A (parallel contacts), rated voltage (III/2): 125 V, number of positions: 5, product range: TBUS5-22,5.., pitch: 3.81 mm, mounting: DIN rail mounting, locking: without, mounting: without, type of packaging: packed in cardboard, Item with gold-plated contacts, bus connectors for connecting with electronics housings, 5 parallel contacts
Why Proax for Phoenix Contact 2708193?
Proax is an authorized distributor of Phoenix Contact 2708193 and one of Phoenix Contact's largest distributors in North America. Our highly skilled in-house technical team is ready to assist with any technical needs.
Have a question in mind? to help you get the right product as quickly as possible for your project. We're always here to help!
Short Lead Time
Highly Trained Staff
Live Chat
Technical Support
Local Inventory
60+ Years Experience
Additional Information
Pack Size | 1 |