Official Distributor
SKU
MPN
FL MC EF WDM-B SC
Weight
0.171 kg
This product is Not Cancellable/Not Returnable
FL MC EF WDM-B SC - FO converters
FO converter (replacement device B), for full duplex transmission from 10/100Base-T(X) to individual simplex fiberglass with WDM (wavelength division multiplex) technology, SC simplex fiber optic connection (1550/1310 nm). Device set (type A and type B) required for operation.
- Full duplex communication with only one fiber
- Transmission ranges up to 38 km
- Auto negotiation
- Auto MDI/MDI-X switch-over
- Link fault pass through (LFPT) and far end fault (FEF) functions for easy connection monitoring
- 10/100 Mbps
- Shipbuilding approval in accordance with DNV GL
Technical Specifications
Utilization restriction
EMC note | EMC: class A product, see manufacturer's declaration in the download area |
CCCex note | Use in potentially explosive areas is not permitted in China. |
Product properties
MTTF | 1400 Years (SN 29500 standard, temperature 25°C, operating cycle 21%) |
MTTF | 599 Years (SN 29500 standard, temperature 40°C, operating cycle 34.25%) |
MTTF | 101 Years (SN 29500 standard, temperature 40°C, operating cycle 100%) |
MTBF | 492 Years (Telcordia standard, 25°C temperature, 21% operating cycle (5 days a week, 8 hours a day)) |
MTBF | 133 Years (Telcordia standard, 40°C temperature, 34.25% operating cycle (5 days a week, 12 hours a day)) |
Signal delay | ± 1.3 µs (Store and Forward mode, 10/100 Mbps, depending on the frame size) |
Functionality
Basic Functions | Store-and-forward media converter |
Electrical properties
Electrical isolation | according to IEEE 802.3 |
Electrical isolation | VCC // FE // Ethernet |
Maximum power dissipation for nominal condition | 2.64 W |
Test voltage data interface/power supply | 0.5 kVrms (50 Hz, 1 min.) |
Supply
Supply Voltage Range | 18 V DC ... 30 V DC (Screw connection) |
Supply Voltage Range | 18 V DC ... 30 V DC (as an alternative or redundant, via backplane bus contact and system current supply) |
Typical current consumption | < 110 mA (24 V DC) |
Protective circuit | Reverse polarity protection |
Connection Method | Plug-in screw terminal block (COMBICON), redundancy possible |
Single conductor/terminal point, rigid | 0.2 mm² ... 2.5 mm² |
Single-wire/terminal point, flexible | 0.2 mm² ... 2.5 mm² |
Conductor cross section, flexible [AWG] | 24 ... 14 |
Stripping length | 7.00 mm |
Tightening torque | 0.56 Nm ... 0.79 Nm |
Interfaces
Signal | Ethernet |
Basic Functions | Store-and-forward media converter |
Data: optical FO
Transmit capacity, minimum | ≥ -14 dBm ((9/125 µm) dynamic in link mode (average)) |
Transmit capacity, maximum | ≤ -8 dBm ((9/125 µm) dynamic in link mode (average)) |
Transmission length incl. 3 dB system reserve | 38 km (F-E 9/125 0.36 dB/km) |
Transmission length incl. 3 dB system reserve | 34 km (F-E 9/125 0.4 dB/km) |
Transmission length incl. 3 dB system reserve | 28 km (F-E 9/125 0.5 dB/km) |
Transmission length incl. 3 dB system reserve | 21 km (F-G 62.5/125 0.7 dB/km F 1000) |
Transmission length incl. 3 dB system reserve | 5.5 km (F-G 62.5/125 2.6 dB/km F 600) |
Transmission length incl. 3 dB system reserve | 21 km (F-G 50/125 0.7 dB/km F 1200) |
Transmission length incl. 3 dB system reserve | 9 km (F-G 50/125 1.6 dB/km F 800) |
Connection Method | SC simplex |
Wavelength | 1550 nm (Send) |
Wavelength | 1310 nm (Receiving) |
Minimum receiver sensitivity | min. -31 dBm (dynamic in link mode (average)) |
Maximum receiver sensitivity | -3 dBm (dynamic in link mode (average)) |
Transmission medium | Multi-mode fiberglass |
Transmission medium | Single-mode fiberglass |
Data: Ethernet interface, 10/100Base-T(X) in accordance with IEEE 802.3
Transmission Speed | 10/100 Mbps |
Connection Method | RJ45 jack, shielded |
No. of channels | 1 |
Transmission length | 100 m (shielded twisted pair) |
Transmission medium | Copper |
Signal LEDs | Activity, link status, 10/100 Mbps |
Auto-negotiation modes | Auto |
Link through | Link fault pass through |
MDI-/MDI-X switchover | Auto-MDI(X) |
Dimensions
Width | 22.5 mm |
Height | 99 mm |
Depth | 114.5 mm |
Material specifications
Color (Housing) | green (RAL 6021) |
Material (Housing) | PA 6.6-FR |
FO cable
Fiber types | 50/125 µm |
Fiber types | 62.5/125 µm |
Fiber types | Fiberglass |
Ambient conditions
Degree of Protection | IP20 |
Ambient Temperature (Operation) | -40 °C ... 65 °C |
Ambient temperature (storage/transport) | -40 °C ... 85 °C |
Altitude | ≤ 5000 m (For restrictions, see the manufacturer's declaration for altitude operation) |
Altitude | ≤ 2000 m (in acc. with UL) |
Permissible humidity (operation) | 5 % ... 95 % (non-condensing) |
Permissible humidity (storage/transport) | 5 % ... 95 % (non-condensing) |
CE
Certificate | CE-compliant |
ATEX
Identification | II 3 G Ex nA IIC T4 Gc X |
Note | Please follow the special installation instructions in the documentation! |
UL, USA/Canada
Identification | 508 Listed |
Identification | Class I, Zone 2, AEx nA IIC T4 |
Identification | Class I, Zone 2, Ex nA IIC T4 Gc X |
Identification | Class I, Div. 2, Groups A, B, C, D |
Corrosive gas test
Identification | ISA-S71.04-1985 G3 Harsh Group A |
Shipbuilding
Identification | DNV GL |
DNV GL data
Temperature | B |
Humidity | A |
Vibration | A |
EMC | B |
Enclosure | Required protection according to the Rules shall be provided upon installation on board |
EMC data
Electromagnetic compatibility | Conformance with EMC Directive 2014/30/EU |
Electrostatic discharge
Standards/regulations | EN 61000-4-2 |
Contact discharge | ± 6 kV (Test Level 3) |
Discharge in air | ± 8 kV (Test Level 3) |
Indirect discharge | ± 6 kV |
Comments | Criterion B |
Electromagnetic HF field
Standards/regulations | EN 61000-4-3 |
Frequency Range | 80 MHz ... 3 GHz (Test Level 3) |
Field intensity | 10 V/m |
Comments | Criterion A |
Fast transients (burst)
Standards/regulations | EN 61000-4-4 |
Input | ± 2 kV (Test Level 3) |
Signal | ± 2 kV (Test Level 3) |
Comments | Criterion B |
Surge current load (surge)
Standards/regulations | EN 61000-4-5 |
Input | ± 0.5 kV (DC supply) |
Signal | ± 1 kV (Data line, asymmetrical) |
Comments | Criterion B |
Conducted interference
Standards/regulations | EN 61000-4-6 |
Frequency Range | 0.15 MHz ... 80 MHz |
Comments | Criterion A |
Voltage | 10 V |
Emitted interference
Standards/regulations | EN 55032 |
Comments | Class A, industrial applications |
Criteria
Criterion A | Normal operating behavior within the specified limits. |
Criterion B | Temporary impairment to operational behavior that is corrected by the device itself. |
Standards and Regulations
Free from substances that could impair the application of coating | in accordance with VW-AUDI-Seat central standard P-VW 3.10.7 57 65 0 |
Electrical isolation | according to IEEE 802.3 |
Mounting
Mounting Type | DIN rail mounting |
Accessories
- 2707437 - DIN rail connector, color: green, nominal current: 8 A (parallel contacts), rated voltage (III/2): 125 V, number of positions: 5, product range: TBUS5-22,5.., pitch: 3.81 mm, mounting: DIN rail mounting, locking: without, mounting: without, type of packaging: packed in cardboard, Item with gold-plated contacts, bus connectors for connecting with electronics housings, 5 parallel contacts
Why Proax for Phoenix Contact 2902659?
Proax is an authorized distributor of Phoenix Contact 2902659 and one of Phoenix Contact's largest distributors in North America. Our highly skilled in-house technical team is ready to assist with any technical needs.
Have a question in mind? to help you get the right product as quickly as possible for your project. We're always here to help!
Short Lead Time
Highly Trained Staff
Live Chat
Technical Support
Local Inventory
60+ Years Experience
Additional Information
Pack Size | 1 |