Proax

Currency
0 Items
proax logo
Cart
Phoenix ContactOfficial Distributor

By Phoenix Contact

SKU
MPN
FL MC EF 1300 MM SC
Weight
0.171 kg
Series FL-MC-EF

FL MC EF 1300 MM SC - FO converters

FO converter with SC duplex fiber optic connection (1300 nm), for converting 10/100Base-T(X) to multi-mode fiberglass (50/125 µm). Auto negotiation and auto MDI(X) function. Comprehensive link diagnostics. DIN-rail mountable, 18 ... 30 V DC supply.

  • Transmission ranges up to 10 km
  • Auto negotiation
  • Auto MDI/MDI-X switch-over
  • Link fault pass through (LFPT) and far end fault (FEF) functions for easy connection monitoring
  • 10/100 Mbps
  • Shipbuilding approval in accordance with DNV GL
Technical Specifications

Utilization restriction

CCCex noteUse in potentially explosive areas is not permitted in China.

Product properties

MTTF1400 Years (SN 29500 standard, temperature 25°C, operating cycle 21%)
MTTF599 Years (SN 29500 standard, temperature 40°C, operating cycle 34.25%)
MTTF101 Years (SN 29500 standard, temperature 40°C, operating cycle 100%)
MTBF479 Years (Telcordia standard, 25°C temperature, 21% operating cycle (5 days a week, 8 hours a day))
MTBF140 Years (Telcordia standard, 40°C temperature, 34.25% operating cycle (5 days a week, 12 hours a day))
Signal delay± 1.3 µs (Store and Forward mode, 10/100 Mbps, depending on the frame size)

Functionality

Basic FunctionsStore-and-forward media converter

Electrical properties

Electrical isolationaccording to IEEE 802.3
Electrical isolationVCC // FE // Ethernet
Maximum power dissipation for nominal condition2.4 W
Test voltage data interface/power supply0.5 kVrms (50 Hz, 1 min.)

Supply

Supply Voltage Range18 V DC ... 30 V DC (Screw connection)
Supply Voltage Range18 V DC ... 30 V DC (as an alternative or redundant, via backplane bus contact and system current supply)
Typical current consumption< 100 mA (24 V DC)
Protective circuitReverse polarity protection
Connection MethodPlug-in screw terminal block (COMBICON), redundancy possible
Single conductor/terminal point, rigid0.2 mm² ... 2.5 mm²
Single-wire/terminal point, flexible0.2 mm² ... 2.5 mm²
Conductor cross section, flexible [AWG]24 ... 14
Stripping length7.00 mm
Tightening torque0.56 Nm ... 0.79 Nm

Interfaces

SignalEthernet
Basic FunctionsStore-and-forward media converter

Data: optical FO

Transmit capacity, minimum≥ -23.5 dBm ((50/125 µm) dynamic in link mode (average))
Transmit capacity, minimum≥ -20 dBm ((62,5/125 µm) dynamic in link mode (average))
Transmit capacity, maximum≤ -14 dBm ((50/125 µm) dynamic in link mode (average))
Transmit capacity, maximum≤ -14 dBm ((62,5/125 µm) dynamic in link mode (average))
Transmission length incl. 3 dB system reserve6.4 km (F-G 50/125 0.7 dB/km F 1000)
Transmission length incl. 3 dB system reserve2.8 km (F-G 50/125 1.6 dB/km F 800)
Transmission length incl. 3 dB system reserve10 km (F-G 62.5/125 0.7 dB/km F 1000)
Transmission length incl. 3 dB system reserve3 km (F-G 62.5/125 2.6 dB/km F 600)
Connection MethodSC duplex
Wavelength1300 nm
Minimum receiver sensitivity-31 dBm (dynamic in link mode (average))
Maximum receiver sensitivity-14 dBm (dynamic in link mode (average))
Transmission mediumMulti-mode fiberglass
Transmission mediumGI-HCS fiber

Data: Ethernet interface, 10/100Base-T(X) in accordance with IEEE 802.3

Transmission Speed10/100 Mbps
Connection MethodRJ45 jack, shielded
No. of channels1
Transmission length100 m (shielded twisted pair)
Transmission mediumCopper
Signal LEDsActivity, link status, 10/100 Mbps
Auto-negotiation modesAuto
Link throughLink fault pass through
MDI-/MDI-X switchoverAuto-MDI(X)

Dimensions

Width22.5 mm
Height99 mm
Depth114.5 mm

Material specifications

Color (Housing)green (RAL 6021)
Material (Housing)PA 6.6-FR

FO cable

Fiber types50/125 µm
Fiber types62.5/125 µm
Fiber typesFiberglass

Ambient conditions

Degree of ProtectionIP20
Ambient Temperature (Operation)-40 °C ... 65 °C
Ambient temperature (storage/transport)-40 °C ... 85 °C
Altitude≤ 5000 m (For restrictions, see the manufacturer's declaration for altitude operation)
Altitude≤ 2000 m (in acc. with UL)
Permissible humidity (operation)5 % ... 95 % (non-condensing)
Permissible humidity (storage/transport)5 % ... 95 % (non-condensing)

CE

CertificateCE-compliant

ATEX

Identification II 3 G Ex nA IIC T4 Gc X
NotePlease follow the special installation instructions in the documentation!

ATEX, FO interface

Identification II (2) D [Ex op is Db] IIIC
Identification II (2) G [Ex op is Gb] IIC
CertificatePTB 06 ATEX 2042 U
NotePlease follow the special installation instructions in the documentation!

UL, USA/Canada

Identification508 Listed
IdentificationClass I, Zone 2, AEx nA IIC T4
IdentificationClass I, Zone 2, Ex nA IIC T4 Gc X
IdentificationClass I, Div. 2, Groups A, B, C, D

KC approval for South Korea

CertificateMSIP-REI-PCK-2902853

Corrosive gas test

IdentificationISA-S71.04-1985 G3 Harsh Group A

Shipbuilding

IdentificationDNV GL

DNV GL data

TemperatureB
HumidityA
VibrationA
EMCB
EnclosureRequired protection according to the Rules shall be provided upon installation on board

EMC data

Electromagnetic compatibilityConformance with EMC Directive 2014/30/EU

Electrostatic discharge

Standards/regulationsEN 61000-4-2
Contact discharge± 6 kV (Test Level 3)
Discharge in air± 8 kV (Test Level 3)
Indirect discharge± 6 kV
CommentsCriterion B

Electromagnetic HF field

Standards/regulationsEN 61000-4-3
Frequency Range80 MHz ... 3 GHz (Test Level 3)
Field intensity10 V/m
CommentsCriterion A

Fast transients (burst)

Standards/regulationsEN 61000-4-4
Input± 2 kV (Test Level 3)
Signal± 2 kV (Test Level 3)
CommentsCriterion B

Surge current load (surge)

Standards/regulationsEN 61000-4-5
Input± 0.5 kV (DC supply)
Signal± 1 kV (Data line, asymmetrical)
CommentsCriterion B

Conducted interference

Standards/regulationsEN 61000-4-6
Frequency Range0.15 MHz ... 80 MHz
CommentsCriterion A
Voltage10 V

Emitted interference

Standards/regulationsEN 55032
CommentsClass A, industrial applications

Criteria

Criterion ANormal operating behavior within the specified limits.
Criterion BTemporary impairment to operational behavior that is corrected by the device itself.

Standards and Regulations

Free from substances that could impair the application of coatingin accordance with VW-AUDI-Seat central standard P-VW 3.10.7 57 65 0
Electrical isolationaccording to IEEE 802.3

Mounting

Mounting TypeDIN rail mounting
Accessories

Why Proax for Phoenix Contact 2902853?

Proax is an authorized distributor of Phoenix Contact 2902853 and one of Phoenix Contact's largest distributors in North America. Our highly skilled in-house technical team is ready to assist with any technical needs.

Have a question in mind? to help you get the right product as quickly as possible for your project. We're always here to help!

Short Lead Time
Highly Trained Staff
Live Chat
Technical Support
Local Inventory
60+ Years Experience
Additional Information

Pack Size1
Recommended

Not in stock

Request lead time or order—we'll ensure quick delivery

Phoenix Contact Availability