Official Distributor
SKU
MPN
NBC-R4AC/10G-R4AC/10G-94F/3,0
Weight
0.16 kg
This product is Not Cancellable/Not Returnable
Series NBC-R
NBC-R4AC/10G-R4AC/10G-94F/3,0 - Patch cable
Patch cable, CAT6A, 4-pair, shielded, connection not crossed (line), assembled at both ends with RJ45/IP20 connectors, outer sheath material: PUR, length: 3.0 m
- Compact angle
- Perfect for industrial applications
- PVC cable for flexible installations
- Worldwide approval with CE, UL, WEEE, and EAC
- Secure connection and disconnection with reliable locking clip protection
- Ideal EMC properties, thanks to 360° shielding
- Simultaneous power transmission with PoE++
- Resistant to shock and vibrations, thanks to robust molding
- High-speed data transmission with up to 1 Gbps (CAT5)
Technical Specifications
Product properties
Sensor Type | Ethernet |
Number of Positions | 8 |
Shielded | yes |
Signaling
Status display | No |
Status display present | No |
Electrical properties
Rated voltage (III/3) | 72 V (DC) |
Nominal voltage UN | 48 V |
Nominal current IN | 0.5 A |
Transmission medium | Copper |
Transmission characteristics (category) | CAT6A |
Transmission Speed | 10 Gbps |
Mechanical data
Insertion force per signal contact | 50.00 N |
Extraction force per signal contact | 30 N |
Connection 1
Type | Plug straight RJ45 |
Shielded | yes |
Insertion/withdrawal cycles | ≥ 750 |
Degree of Protection | IP20 |
Connection 2
Type | Plug straight RJ45 |
Shielded | yes |
Insertion/withdrawal cycles | ≥ 750 |
Degree of Protection | IP20 |
Cable/line
Cable Length | 3.00 m |
Ethernet 10 Gbit [94F]
Shielded | yes |
UL AWM style | 20963 (80°C/30 V) |
Cable weight | 42 kg/km |
Cable Type | Ethernet 10 Gbit |
Short symbol | 02YSC11Y |
Cable type (abbreviation) | 94F |
Signal type/category | Ethernet CAT6A, 10 Gbps |
Cable structure | 4x2xAWG26/7; S/FTP |
External Cable Diameter | 6.40 mm ±0.2 mm |
Outer sheath, material | PUR |
External sheath, color | water blue RAL 5021 |
Thickness, outer sheath | 0.65 mm |
Conductor material | Bare Cu litz wires |
Conductor structure signal line | 7x 0.16 mm |
AWG Signal Line | 26 |
Conductor Cross Section | 4x 2x 0.14 mm² |
Material wire insulation | Foamed PE |
Wire diameter incl. insulation | 1.04 mm |
Single wire, color | white/blue-blue, white/orange-orange, white/green-green, white/brown-brown |
Twisted pairs | 2 cores to the pair |
Type of pair shielding | Aluminum-lined foil |
Overall twist | 4 pairs for core |
Shielding | Tinned copper braided shield |
Optical shield covering | 70 % |
Nominal voltage, cable | ≤ 100 V |
Test voltage Core/Core | 700 V (50 Hz, 1 min.) |
Test voltage Core/Shield | 700.00 V (50 Hz, 1 min.) |
Cable insulation resistance | ≥ 500 MΩ*km |
Wave impedance | 100 Ω ±5 Ω (at 100 MHz) |
Loop resistance | ≤ 290.00 Ω/km |
Cable capacity | 47 nF/km |
Signal runtime | 5.13 ns/m |
Tensile strength | ≤ 100 N |
Minimum bending radius, fixed installation | 4 x D |
Minimum bending radius, flexible installation | 8 x D |
Near end crosstalk attenuation (NEXT) | 75.3 dB (with 1 MHz) |
Near end crosstalk attenuation (NEXT) | 66.3 dB (at 4 МHz) |
Near end crosstalk attenuation (NEXT) | 61.8 dB (at 8 МHz) |
Near end crosstalk attenuation (NEXT) | 60.3 dB (at 10 MHz) |
Near end crosstalk attenuation (NEXT) | 57.2 dB (at 16 MHz) |
Near end crosstalk attenuation (NEXT) | 55.8 dB (at 20 МHz) |
Near end crosstalk attenuation (NEXT) | 54.3 dB (at 25 MHz) |
Near end crosstalk attenuation (NEXT) | 52.8 dB (at 31.25 МHz) |
Near end crosstalk attenuation (NEXT) | 48.4 dB (at 62.5 МHz) |
Near end crosstalk attenuation (NEXT) | 45.3 dB (at 100 MHz) |
Near end crosstalk attenuation (NEXT) | 40.8 dB (at 200 MHz) |
Near end crosstalk attenuation (NEXT) | 39.3 dB (at 250 MHz) |
Near end crosstalk attenuation (NEXT) | 38.1 dB (at 300 MHz) |
Near end crosstalk attenuation (NEXT) | 38.1 dB (at 400 MHz) |
Near end crosstalk attenuation (NEXT) | 38.1 dB (at 500 MHz) |
Power-summated near end crosstalk attenuation (PSNEXT) | 72.3 dB (with 1 MHz) |
Power-summated near end crosstalk attenuation (PSNEXT) | 63.3 dB (at 4 МHz) |
Power-summated near end crosstalk attenuation (PSNEXT) | 58.8 dB (at 8 МHz) |
Power-summated near end crosstalk attenuation (PSNEXT) | 57.3 dB (at 10 MHz) |
Power-summated near end crosstalk attenuation (PSNEXT) | 54.2 dB (at 16 MHz) |
Power-summated near end crosstalk attenuation (PSNEXT) | 52.8 dB (at 20 МHz) |
Power-summated near end crosstalk attenuation (PSNEXT) | 51.3 dB (at 25 MHz) |
Power-summated near end crosstalk attenuation (PSNEXT) | 49.9 dB (at 31.25 МHz) |
Power-summated near end crosstalk attenuation (PSNEXT) | 45.4 dB (at 62.5 МHz) |
Power-summated near end crosstalk attenuation (PSNEXT) | 42.3 dB (at 100 MHz) |
Power-summated near end crosstalk attenuation (PSNEXT) | 37.8 dB (at 200 MHz) |
Power-summated near end crosstalk attenuation (PSNEXT) | 36.3 dB (at 250 MHz) |
Power-summated near end crosstalk attenuation (PSNEXT) | 35.1 dB (at 300 MHz) |
Power-summated near end crosstalk attenuation (PSNEXT) | 33.3 dB (at 400 MHz) |
Power-summated near end crosstalk attenuation (PSNEXT) | 31.8 dB (at 500 MHz) |
Return attenuation (RL) | 20 dB (with 1 MHz) |
Return attenuation (RL) | 23 dB (at 4 МHz) |
Return attenuation (RL) | 24.5 dB (at 8 МHz) |
Return attenuation (RL) | 25 dB (at 10 MHz) |
Return attenuation (RL) | 25 dB (at 16 MHz) |
Return attenuation (RL) | 25 dB (at 20 МHz) |
Return attenuation (RL) | 24.2 dB (at 25 MHz) |
Return attenuation (RL) | 23.3 dB (at 31.25 МHz) |
Return attenuation (RL) | 20.7 dB (at 62.5 МHz) |
Return attenuation (RL) | 19 dB (at 100 MHz) |
Return attenuation (RL) | 16.4 dB (at 200 MHz) |
Return attenuation (RL) | 15.6 dB (at 250 MHz) |
Return attenuation (RL) | 15.6 dB (at 300 MHz) |
Return attenuation (RL) | 15.6 dB (at 400 MHz) |
Return attenuation (RL) | 15.6 dB (at 500 MHz) |
Shield attenuation | ≥ 80.00 dB (at 30 ... 100 MHz) |
Halogen-free | according to IEC 60754-1 |
Resistance to Oil | in accordance with DIN EN 60811-2-1 |
Flame resistance | according to IEC 60332-1-2 |
Ambient Temperature (Operation) | -20 °C ... 80 °C (Cable, flexible installation) |
Ambient Temperature (Operation) | -40 °C ... 80 °C (cable, fixed installation) |
Ambient conditions
Degree of Protection | IP20 |
Degree of Protection | IP20 |
Ambient Temperature (Operation) | -20 °C ... 70 °C (RJ45 connector) |
Ambient Temperature (Operation) | -20 °C ... 80 °C (cable, fixed installation) |
Why Proax for Phoenix Contact 1408365?
Proax is an authorized distributor of Phoenix Contact 1408365 and one of Phoenix Contact's largest distributors in North America. Our highly skilled in-house technical team is ready to assist with any technical needs.
Have a question in mind? to help you get the right product as quickly as possible for your project. We're always here to help!
Short Lead Time
Highly Trained Staff
Live Chat
Technical Support
Local Inventory
60+ Years Experience
Additional Information
Pack Size | 1 |
Recommended