SKU
MPN
NBC-R4AC/15,0-93E/R4AC
Weight
0.649 kg
This product is Not Cancellable/Not Returnable
Series NBC-R

NBC-R4AC/15,0-93E/R4AC - Network cable

Assembled Ethernet cable, CAT5e, shielded, 2-pair, 26* AWG stranded (7-wire), RAL 5021 (water blue), RJ45 plug/IP20 to RJ45 plug/IP20, line, length: 15 m

  • Perfect for industrial applications
  • Perfect for office, building, and protected industrial applications (e.g., in control cabinets)
  • Compact angle
Technical Specifications

Product properties

Sensor TypeEthernet
Number of Positions4
No. of cable outlets1
Number of slots1
Shieldedyes
Cable outletstraight

Signaling

Status displayNo
Status display presentNo

Electrical properties

Rated voltage (III/3)72 V (DC)
Nominal voltage UN48 V
Nominal current IN1 A
Transmission mediumCopper
Transmission characteristics (category)CAT5 (IEC 11801:2002)
Transmission Speed100 Mbps

Mechanical data

Insertion/withdrawal cycles≥ 750
Insertion force per signal contact50.00 N
Extraction force per signal contact30 N

Material specifications

Flammability rating according to UL 94V2
Outer sheath, materialPUR

Connection 1

TypePlug straight RJ45
Shieldedyes
Handle colorgray
MaterialCuSn (Contact)
MaterialNi/Au (Contact surface)
MaterialPC (Contact carriers)
MaterialPA (Housing)
Insertion/withdrawal cycles≥ 750
Degree of ProtectionIP20
Ambient Temperature (Operation)-40 °C ... 60 °C

Connection 2

TypePlug straight RJ45
Shieldedyes
Handle colorgray
MaterialCuSn (Contact)
MaterialNi/Au (Contact surface)
MaterialPC (Contact carriers)
MaterialPA (Housing)
Insertion/withdrawal cycles≥ 750
Degree of ProtectionIP20
Ambient Temperature (Operation)-40 °C ... 60 °C

Cable/line

Cable Length15.00 m

Ethernet flexible CAT5, 2-pair [93E]

Shieldedyes
UL AWM style20963 (80°C/30 V)
Cable weight42 kg/km
Cable TypeEthernet flexible CAT5, 2-pair
Short symbol02YS(ST)C11Y
Cable type (abbreviation)93E
Signal type/categoryEthernet CAT5 (IEC 11801), 100 Mbps
Cable structure2x2xAWG26/7, SF/UTP
External Cable Diameter6.40 mm ±0.2 mm
Outer sheath, materialPUR
External sheath, colorwater blue RAL 5021
Thickness, outer sheath1.20 mm
Conductor materialBare Cu litz wires
Conductor structure signal line7x 0.16 mm
AWG Signal Line26
Conductor Cross Section2x 2x 0.14 mm²
Material wire insulationFoamed PE
Wire diameter incl. insulation0.98 mm
Single wire, colorwhite/orange-orange, white/green-green
Twisted pairs2 cores to the pair
Overall twistTwo pairs with two fillers to the core
ShieldingAluminum-coated foil, tinned copper braided shield
Optical shield covering70 %
Current carrying capacity of cable2.00 A (according to DIN VDE 0891-1)
Nominal voltage, cable≤ 100 V (Peak value, not for high-power applications)
Test voltage Core/Core700 V (50 Hz, 1 min.)
Test voltage Core/Shield700.00 V (50 Hz, 1 min.)
Cable insulation resistance≥ 500 MΩ*km
Coupling resistance≤ 100.00 mΩ/m (at 10 MHz)
Wave impedance100 Ω ±5 Ω (at 100 MHz)
Loop resistance≤ 290.00 Ω/km
Cable capacityapprox. 45 nF/km (at 1 kHz)
Signal runtime5.3 ns/m
Tensile strength≤ 80 N
Minimum bending radius, fixed installation4 x D
Minimum bending radius, flexible installation8 x D
Near end crosstalk attenuation (NEXT)65.3 dB (with 1 MHz)
Near end crosstalk attenuation (NEXT)56.3 dB (at 4 МHz)
Near end crosstalk attenuation (NEXT)50.3 dB (at 10 MHz)
Near end crosstalk attenuation (NEXT)47.2 dB (at 16 MHz)
Near end crosstalk attenuation (NEXT)45.8 dB (at 20 МHz)
Near end crosstalk attenuation (NEXT)42.9 dB (at 31.25 МHz)
Near end crosstalk attenuation (NEXT)38.4 dB (at 62.5 МHz)
Near end crosstalk attenuation (NEXT)35.3 dB (at 100 MHz)
Power-summated near end crosstalk attenuation (PSNEXT)62.3 dB (with 1 MHz)
Power-summated near end crosstalk attenuation (PSNEXT)53.3 dB (at 4 МHz)
Power-summated near end crosstalk attenuation (PSNEXT)47.3 dB (at 10 MHz)
Power-summated near end crosstalk attenuation (PSNEXT)44.2 dB (at 16 MHz)
Power-summated near end crosstalk attenuation (PSNEXT)42.8 dB (at 20 МHz)
Power-summated near end crosstalk attenuation (PSNEXT)39.9 dB (at 31.25 МHz)
Power-summated near end crosstalk attenuation (PSNEXT)35.4 dB (at 62.5 МHz)
Power-summated near end crosstalk attenuation (PSNEXT)32.3 dB (at 100 MHz)
Return attenuation (RL)23 dB (at 4 МHz)
Return attenuation (RL)24.1 dB (at 8 МHz)
Return attenuation (RL)25 dB (at 10 MHz)
Return attenuation (RL)25 dB (at 16 MHz)
Return attenuation (RL)25 dB (at 20 МHz)
Return attenuation (RL)23.6 dB (at 31.25 МHz)
Return attenuation (RL)21.5 dB (at 62.5 МHz)
Return attenuation (RL)20.1 dB (at 100 MHz)
Halogen-freeaccording to IEC 60754-1
Resistance to Oilin accordance with EN 60811-2-1
Flame resistanceaccording to IEC 60332-1-2
Flame resistancein acc. to UL VW1
Flame resistancein accordance with UN ECE-R 118.03
Ambient Temperature (Operation)-20 °C ... 80 °C (Cable, flexible installation)
Ambient Temperature (Operation)-40 °C ... 80 °C (cable, fixed installation)

Ambient conditions

Degree of ProtectionIP20 (RJ45 connector)
Degree of ProtectionIP20
Ambient Temperature (Operation)-40 °C ... 60 °C (RJ45 connector)

Why Proax for Phoenix Contact 1412089?

Proax is an authorized distributor of Phoenix Contact 1412089 and one of Phoenix Contact's largest distributors in North America. Our highly skilled in-house technical team is ready to assist with any technical needs.

Have a question in mind? to help you get the right product as quickly as possible for your project. We're always here to help!

Short Lead Time
Highly Trained Staff
Live Chat
Technical Support
Local Inventory
60+ Years Experience
Additional Information

Pack Size1
Recommended

Available for order

Phoenix Contact Availability