AXL F RTD4 XC 1H - Temperature module
Axioline F, Temperature recording module, Analog inputs: 4 (for resistance temperature detectors), connection technology: 2-, 3-, 4-conductor (shielded), transmission speed in the local bus: 100 Mbps, Extreme conditions version, degree of protection: IP20, including bus base module and Axioline F connectors
- 4 analog input channels for connecting resistance temperature detectors (RTDs)
- 500 Ω and 5 kΩ linear inputs
- Connection of sensors in 2-, 3-, and 4-conductor technology
- Integrated, digital sensor linearization
- Standardized measured value representation directly in °C, °F or Ω
- Measured value display in 16-bit format or floating point format
- Programmable filters
- Short-circuit protected inputs
- Temperature stability
- Very high level of noise immunity
- Low noise emission
- Installation monitoring by means of “Channel scout” function
- Can be used under extreme ambient conditions
- Extended temperature range of -40 °C ... +70 °C (see “Tested successfully: use under extreme ambient conditions” in the data sheet)
- Partially coated PCBs
- Device rating plate stored
Technical Specifications
Dimensions
Width | 35 mm |
Height | 126.1 mm |
Depth | 54 mm |
Note on dimensions | The depth applies when a TH 35-7.5 DIN rail is used (in accordance with EN 60715). |
Axioline F local bus
Number of interfaces | 2 |
Connection Method | Bus base module |
Transmission Speed | 100 Mbps |
Module
Input address area | 8 Byte |
Output address area | 8 Byte |
Required parameter data | 12 Byte |
Required configuration data | 6 Byte |
Analog
Input name | Analog inputs |
Description of the input | Inputs for resistive temperature sensors |
Number of Inputs | 4 (for resistance temperature detectors) |
Connection Method | Push-in connection |
Connection technology | 2-, 3-, 4-conductor (shielded) |
A/D converter resolution | 24 bit |
Sensor types (RTD) that can be used | Pt, Ni, KTY, Cu sensors |
Data formats | IB IL, S7-compatible |
Measured value representation | 16 bits (15 bits + sign bit) |
Input filter time | 40 ms |
Input filter time | 60 ms |
Input filter time | 100 ms |
Input filter time | 120 ms (adjustable) |
Nominal value of the current sources | 1 mA (Pt 100, Ni 100, RLin 500 Ω; pulse current, the specification is valid during the sampling phase) |
Nominal value of the current sources | 210 µA (P t1000, Ni 1000, RLin 5000 Ω; pulse current, the specification is valid during the sampling phase) |
Differential non-linearity | typ. 1 ppm / ±0.0001 % (in all ranges) |
Integral non-linearity | typ. 30 ppm / ±0.003 % (Pt 100) |
Integral non-linearity | typ. 20 ppm / ±0.002 % (RLin 500 Ω) |
Integral non-linearity | typ. 200 ppm / ±0.02 % (RLin 5000 Ω) |
Linear resistance measuring range | 0 Ω ... 500 Ω |
Linear resistance measuring range | 0 kΩ ... 5 kΩ |
Protective circuit | Short-circuit protection, overload protection of the inputs |
Protective circuit | Transient protection of inputs |
Protective circuit | Transient protection of sensor supplies |
Product properties
Product family | Axioline F |
Type | block modular |
Mounting Position | any (no temperature derating) |
Scope of delivery | including bus base module and Axioline F connectors |
Special Properties | Extreme conditions version |
Insulation characteristics
Overvoltage category | II (IEC 60664-1, EN 60664-1) |
Pollution degree | 2 (IEC 60664-1, EN 60664-1) |
Potentials
Power consumption | max. 1.1 W (entire device) |
Potentials: Axioline F local bus supply (UBus)
Supply Voltage | 5 V DC (via bus base module) |
Current draw | max. 140 mA |
Power consumption | max. 700 mW |
Potentials: Supply for analog modules (UA)
Supply Voltage | 24 V DC |
Supply Voltage Range | 19.2 V DC ... 30 V DC (including all tolerances, including ripple) |
Current draw | max. 17 mA |
Power consumption | max. 400 mW |
Protective circuit | Surge protection; electronic (35 V, 0.5 s) |
Protective circuit | Reverse polarity protection; Polarity protection diode |
Protective circuit | Transient protection; Suppressor diode |
Electrical isolation/isolation of the voltage ranges
Test voltage: 5 V supply of the local bus (UBus) / 24 V supply (I/Os) | 500 V AC, 50 Hz, 1 min. |
Test voltage: 5 V supply of the local bus (UBus)/analog inputs | 500 V AC, 50 Hz, 1 min. |
Test voltage: 5 V supply of the local bus (UBus) / functional ground | 500 V AC, 50 Hz, 1 min. |
Test voltage: 24 V supply (I/O)/analog inputs | 500 V AC, 50 Hz, 1 min. |
Test voltage: 24 V supply (I/O) / functional ground | 500 V AC, 50 Hz, 1 min. |
Test voltage: Analog inputs/functional ground | 500 V AC, 50 Hz, 1 min. |
Connection technology
Connection name | Axioline F connector |
Note on the connection method | Please observe the information provided on conductor cross sections in the “Axioline F: system and installation” user manual. |
Conductor connection
Connection Method | Push-in connection |
Conductor cross section rigid | 0.2 mm² ... 1.5 mm² |
Conductor cross section flexible | 0.2 mm² ... 1.5 mm² |
Conductor cross section AWG | 24 ... 16 |
Stripping length | 8 mm |
Axioline F connector
Connection Method | Push-in connection |
Note on the connection method | Please observe the information provided on conductor cross sections in the “Axioline F: system and installation” user manual. |
Conductor cross section, rigid | 0.2 mm² ... 1.5 mm² |
Conductor cross section, flexible | 0.2 mm² ... 1.5 mm² |
Conductor cross section AWG | 24 ... 16 |
Stripping length | 8 mm |
Ambient conditions
Ambient Temperature (Operation) | -25 °C ... 60 °C (Standard, applications with UL approval, use in zone 2 potentially explosive area) |
Ambient Temperature (Operation) | -40 °C ... 70 °C (Extended, see section “Tested successfully: use under extreme ambient conditions” in the data sheet.) |
Degree of Protection | IP20 |
Air pressure (operation) | 70 kPa ... 106 kPa (up to 3000 m above sea level) |
Air pressure (storage/transport) | 70 kPa ... 106 kPa (up to 3000 m above sea level) |
Ambient temperature (storage/transport) | -40 °C ... 85 °C |
Permissible humidity (operation) | 5 % ... 95 % (non-condensing) |
Permissible humidity (storage/transport) | 5 % ... 95 % (non-condensing) |
Standards and Regulations
Protection class | III (IEC 61140, EN 61140, VDE 0140-1) |
ATEX
Identification | II 3 G Ex ec IIC T4 Gc |
Certificate | UL 20 ATEX 2441X |
References to standards | EN IEC 60079-0, EN IEC 60079-7 |
UKEX
Identification | II 3 G Ex ec IIC T4 Gc |
Certificate | PxCIMA22UKEX2701949X |
References to standards | EN IEC 60079-0, EN IEC 60079-7 |
IECEx
Identification | Ex ec IIC T4 Gc |
Certificate | IECEx ULD 20.0026X |
References to standards | IEC 60079-0 Ed. 7, IEC 60079-7 Ed. 5.1 |
UL, USA/Canada
Identification | cULus |
Certificate | E238705 |
UL Ex, USA / Canada
Identification | Class I, Zone 2, AEx ec IIC T4 |
Identification | Class I, Division 2, Groups A, B, C, D, T4 |
Identification | Ex ec IIC T4 Gc X |
Certificate | E366272 |
References to standards | UL 60079-0 Ed. 7 / CSA C22.2 NO. 60079-0 Ed. 4 |
References to standards | UL 60079-7 Ed. 5 / CSA C22.2 NO. 60079-7 Ed. 2 |
CCC / China-Ex
Identification | Ex ec IIC T4 Gc |
Certificate | , 2021122309114456 |
References to standards | GB/T 3836.1-2021, GB/T 3836.3-2021 |
Mounting
Mounting Type | DIN rail mounting |
Mounting Position | any (no temperature derating) |
Accessories
Why Proax for Phoenix Contact 1035430?
Proax is an authorized distributor of Phoenix Contact 1035430 and one of Phoenix Contact's largest distributors in North America. Our highly skilled in-house technical team is ready to assist with any technical needs.
Have a question in mind? to help you get the right product as quickly as possible for your project. We're always here to help!
Short Lead Time
Highly Trained Staff
Live Chat
Technical Support
Local Inventory
60+ Years Experience
Additional Information
Pack Size | 1 |
Recommended
- 2701235 - Axioline F, Temperature recording module, Analog inputs: 8 (for resistance temperature detectors), connection technology: 2-, 3-, 4-conductor (shielded), transmission speed in the local bus: 100 Mbps, Extreme conditions version, degree of protection: IP20, including bus base module and Axioline F connectors
- 2702120 - Axioline F, Temperature recording module, Analog inputs: 8 (for resistance temperature detectors), connection technology: 2-, 4-conductor (shielded), transmission speed in the local bus: 100 Mbps, measuring dynamics up to 8 Hz, degree of protection: IP20, including bus base module and Axioline F connectors
- 2688598 - Axioline F, Temperature recording module, Analog inputs: 4 (4 inputs for thermocouples or linear voltage, plus 1 input -5 V to +5 V), connection technology: 2-conductor (shielded, twisted pair), transmission speed in the local bus: 100 Mbps, degree of protection: IP20, including bus base module and Axioline F connectors
- 2702464 - Axioline F, Temperature recording module, Analog inputs: 8 (8 inputs for thermocouples or linear voltage, plus 1 input -5 V to +5 V), connection technology: 2-conductor (shielded, twisted pair), transmission speed in the local bus: 100 Mbps, Extreme conditions version, degree of protection: IP20, including bus base module and Axioline F connectors
- 2688417 - Axioline F, Temperature recording module, Analog inputs: 8 (8 inputs for thermocouples or linear voltage, plus 1 input -5 V to +5 V), connection technology: 2-conductor (shielded, twisted pair), transmission speed in the local bus: 100 Mbps, degree of protection: IP20, including bus base module and Axioline F connectors