AXL F SGI2 1H - Analog module
Axioline F, Strain gauge capture module, transmission speed in the local bus: 100 Mbps, degree of protection: IP20, including bus base module and Axioline F connectors
- 2 high-precision inputs for strain gauges
- Measuring ranges adjusted with nominal characteristic values upon delivery
- Manual entry of characteristic values
- Process data update can be parameterized in increments between 200 µs and 100 ms
- Path adjustment in the process environment
- 2-point adjustment
- Connection of strain gauges in 6- and 4-conductor technology
- Advanced wire-break detection
- Sensor supply of up to 115 mA (8 load cells with 350 Ω per channel)
- Per channel: low-resistance, floating N/O contact
- The channels are parameterized independently of one another via the bus system
- Tara device
Technical Specifications
Dimensions
Width | 35 mm |
Height | 126.1 mm |
Depth | 54 mm |
Note on dimensions | The depth applies when a TH 35-7.5 DIN rail is used (in accordance with EN 60715). |
Axioline F local bus
Number of interfaces | 2 |
Connection Method | Bus base module |
Transmission Speed | 100 Mbps |
Module
ID code (hex) | none |
Input address area | 12 Byte |
Output address area | 12 Byte |
Required parameter data | 48 Byte |
Required configuration data | 7 Byte |
Analog
Description of the input | Input channels for strain gauge |
Number of Inputs | 2 |
Connection technology | 6 or 4-wire, twisted pair shielded cable |
Bridge difference Ud | Measuring range specified by selecting the characteristic |
Bridge difference Ud | -35 mV ... +35 mV |
Bridge voltage U0 | 5 V |
Measured value representation | 32 bits |
Characteristics | can be parameterized: 350 μV/V ... 6500 μV/V |
Contacts
Description | Floating N/O contact |
Quantity | 2 (Ka1-Kb1, Ka2-Kb2) |
Contact resistance | < 1 Ω (typical) |
Contact resistance | < 3 Ω (maximum) |
Typical response time | typ. 0.2 ms (opening) |
Typical response time | typ. 2 ms (close) |
Analog
Output description | Jumper supply |
Number of Outputs | 2 |
Impedance | > 43 Ω (per channel) |
Output Voltage | typ. 5 V |
Output Current | max. 115 mA (per channel) |
Product properties
Product family | Axioline F |
Type | block modular |
Mounting Position | any (no temperature derating) |
Scope of delivery | including bus base module and Axioline F connectors |
Operating mode | Process data mode with 6 words |
Potentials
Power consumption | typ. 1.5 W (entire device) |
Power consumption | max. 3 W (entire device) |
Potentials: Axioline F local bus supply (UBus)
Supply Voltage | 5 V DC (via bus base module) |
Current draw | max. 75 mA |
Current draw | typ. 65 mA |
Power consumption | max. 375 mW |
Power consumption | typ. 325 mW |
Potentials: Supply for analog modules (UA)
Supply Voltage | 24 V DC |
Supply Voltage Range | 19.2 V DC ... 30 V DC (including all tolerances, including ripple) |
Current draw | typ. 110 mA (with maximum load: 8 weighing cells with 350 Ω per channel) |
Current draw | typ. 25 mA (with typical load: 1 weighing cell with 350 Ω, only one channel loaded) |
Current draw | typ. 55 mA (with maximum load: 8 weighing cells with 350 Ω, only one channel loaded) |
Power consumption | typ. 2.6 W (with maximum load: 8 weighing cells with 350 Ω per channel) |
Protective circuit | Surge protection; Suppressor diode |
Protective circuit | Reverse polarity protection; Polarity protection diode |
Electrical isolation/isolation of the voltage ranges
Test voltage: Logic | 500 V AC, 50 Hz, 1 min. |
Test voltage: 24 V supply (I/O) | 500 V AC, 50 Hz, 1 min. |
Test voltage: Analog inputs | 500 V AC, 50 Hz, 1 min. |
Test voltage: N/O contact Ka1 - Kb1 | 500 V AC, 50 Hz, 1 min. |
Test voltage: N/O contact Ka2 - Kb2 | 500 V AC, 50 Hz, 1 min. |
Test voltage: Functional ground | 500 V AC, 50 Hz, 1 min. |
Connection technology
Connection name | Axioline F connector |
Note on the connection method | Please observe the information provided on conductor cross sections in the “Axioline F: system and installation” user manual. |
Note on the connection method | Applications with UL approval: only use copper conductors. |
Conductor connection
Connection Method | Push-in connection |
Conductor cross section rigid | 0.2 mm² ... 1.5 mm² |
Conductor cross section flexible | 0.2 mm² ... 1.5 mm² |
Conductor cross section AWG | 24 ... 16 |
Stripping length | 8 mm |
Axioline F connector
Connection Method | Push-in connection |
Note on the connection method | Please observe the information provided on conductor cross sections in the “Axioline F: system and installation” user manual. |
Note on the connection method | Applications with UL approval: only use copper conductors. |
Conductor cross section, rigid | 0.2 mm² ... 1.5 mm² |
Conductor cross section, flexible | 0.2 mm² ... 1.5 mm² |
Conductor cross section AWG | 24 ... 16 |
Stripping length | 8 mm |
Ambient conditions
Ambient Temperature (Operation) | -25 °C ... 60 °C |
Degree of Protection | IP20 |
Air pressure (operation) | 70 kPa ... 106 kPa (up to 3000 m above sea level) |
Air pressure (storage/transport) | 70 kPa ... 106 kPa (up to 3000 m above sea level) |
Ambient temperature (storage/transport) | -40 °C ... 85 °C |
Permissible humidity (operation) | 5 % ... 95 % (non-condensing) |
Permissible humidity (storage/transport) | 5 % ... 95 % (non-condensing) |
Standards and Regulations
Protection class | III (IEC 61140, EN 61140, VDE 0140-1) |
Mounting
Mounting Type | DIN rail mounting |
Mounting Position | any (no temperature derating) |
Accessories
Why Proax for Phoenix Contact 2702911?
Proax is an authorized distributor of Phoenix Contact 2702911 and one of Phoenix Contact's largest distributors in North America. Our highly skilled in-house technical team is ready to assist with any technical needs.
Have a question in mind? to help you get the right product as quickly as possible for your project. We're always here to help!
Short Lead Time
Highly Trained Staff
Live Chat
Technical Support
Local Inventory
60+ Years Experience
Additional Information
Pack Size | 1 |
Recommended
- 1035430 - Axioline F, Temperature recording module, Analog inputs: 4 (for resistance temperature detectors), connection technology: 2-, 3-, 4-conductor (shielded), transmission speed in the local bus: 100 Mbps, Extreme conditions version, degree of protection: IP20, including bus base module and Axioline F connectors
- 2701235 - Axioline F, Temperature recording module, Analog inputs: 8 (for resistance temperature detectors), connection technology: 2-, 3-, 4-conductor (shielded), transmission speed in the local bus: 100 Mbps, Extreme conditions version, degree of protection: IP20, including bus base module and Axioline F connectors
- 2702120 - Axioline F, Temperature recording module, Analog inputs: 8 (for resistance temperature detectors), connection technology: 2-, 4-conductor (shielded), transmission speed in the local bus: 100 Mbps, measuring dynamics up to 8 Hz, degree of protection: IP20, including bus base module and Axioline F connectors
- 2688598 - Axioline F, Temperature recording module, Analog inputs: 4 (4 inputs for thermocouples or linear voltage, plus 1 input -5 V to +5 V), connection technology: 2-conductor (shielded, twisted pair), transmission speed in the local bus: 100 Mbps, degree of protection: IP20, including bus base module and Axioline F connectors
- 2688417 - Axioline F, Temperature recording module, Analog inputs: 8 (8 inputs for thermocouples or linear voltage, plus 1 input -5 V to +5 V), connection technology: 2-conductor (shielded, twisted pair), transmission speed in the local bus: 100 Mbps, degree of protection: IP20, including bus base module and Axioline F connectors
- 2702464 - Axioline F, Temperature recording module, Analog inputs: 8 (8 inputs for thermocouples or linear voltage, plus 1 input -5 V to +5 V), connection technology: 2-conductor (shielded, twisted pair), transmission speed in the local bus: 100 Mbps, Extreme conditions version, degree of protection: IP20, including bus base module and Axioline F connectors
- Axioline F, Module d'entrée numérique, Sécurité fonctionnelle, PROFIsafe, destiné uniquement au raccordement sur des contrôleurs Phoenix Contact ou Siemens, Entrées TOR: 4 (avec affectation de deux canaux), 8 (avec affectation d'un canal), 24 V DC, connectique: 2, 3 ou 4 fils, indice de protection: IP20
- Axioline F, Module à relais, Sécurité fonctionnelle, PROFIsafe, destiné uniquement au raccordement sur des contrôleurs Phoenix Contact ou Siemens, Entrées de signalisation: 2, Sorties OUT24V_0 et OUT24V_1: 2, Sorties de relais sécurisées: 4 (indépendant du potentiel), Contact NO, indice de protection: IP20