AXL F PSDOR4/2 1F - Module de sécurité
Axioline F, Module à relais, Sécurité fonctionnelle, PROFIsafe, destiné uniquement au raccordement sur des contrôleurs Phoenix Contact ou Siemens, Entrées de signalisation: 2, Sorties OUT24V_0 et OUT24V_1: 2, Sorties de relais sécurisées: 4 (indépendant du potentiel), Contact NO, indice de protection: IP20
Technical Specifications
Dimensions
Width | 53.6 mm |
Height | 126.1 mm |
Depth | 54 mm |
Note on dimensions | Housing dimensions |
Axioline F local bus
Connection Method | Bus base module |
Module
Input address area | 5 Byte |
Output address area | 6 Byte |
Required parameter data | 20 Byte ((I-and F-parameters)) |
Required configuration data | 10 Byte |
Digital:
Input name | Signal inputs |
Number of Inputs | 2 |
Input Voltage | Power supply from clock outputs UT1 and UT2 |
Nominal input current at UIN | typ. 3.2 mA |
Output name | Outputs OUT24V_0 and OUT24V_1 |
Number of Outputs | 2 |
Nominal Output Voltage | Power supply from U0 or U1 |
Relay
Number of Outputs | 4 (floating) |
Contact switching type | N/O contact |
Switching voltage | min. 12 V AC/DC |
Switching voltage | max. 30 V AC/DC |
Switching current | min. 3 mA |
Switching current | max. 6 A (30 V DC) |
Switching capacity | min. 60 mW |
Limiting Continuous Current | 6 A |
Mechanical service life | 10x 106 cycles |
Output fuse | 6 A gL/gG (See “Application examples” section) |
Product properties
Product family | Axioline F |
Application | Functional safety |
Application | PROFIsafe |
Application | only for connection to Phoenix Contact or Siemens controller |
Type | modular |
Mounting Position | any |
Operating mode | PROFIsafe 2.4, PROFIsafe 2.6.1 |
Insulation characteristics
Overvoltage category | II (IEC 60664-1) |
Pollution degree | 2 (IEC 60664-1) |
Electrical properties
Maximum power dissipation for nominal condition | 6.255 W |
Transmission medium | Copper |
Potentials
Protection | max. 500 mA slow-blow (for UI) |
Protection | max. 6 A gL/gG () |
Protective circuit | Polarity reversal protection of the supply voltage; parallel protection against polarity reversal for a limited period of time |
Protective circuit | Surge voltage detection; at 31 V |
Protective circuit | Undervoltage detection; at 17 V |
Protective circuit | Surge protection of the supply voltage; electronic (35 V, 0.5 s) |
Potentials: Axioline F local bus supply (UBus)
Supply Voltage | 5 V DC (via bus base module) |
Current draw | max. 163 mA (at UBus 5 V DC) |
Current draw | typ. 93 mA (at UBus 5 V DC) |
Potentials: Supply voltage UI for EDM
Supply Voltage | 24 V DC |
Supply Voltage Range | 19.2 V DC ... 30 V DC (including all tolerances, including ripple) |
Current draw | max. 30 mA |
Current draw | typ. 10 mA (Power supply from UI with 30 V DC, all inputs set) |
Potentials: Feed-in U0 and U1 for safe I/O supply
Supply Voltage | 24 V DC |
Supply Voltage Range | 19.2 V DC ... 30 V DC (including all tolerances, including ripple) |
Current draw | max. 6 A |
Current draw | typ. 1.6 mA (Power supply from U0 with 30 V DC, all inputs set without load) |
Connection technology
Connection name | I/O |
Note on the connection method | Note the specification in the section Conductor cross sections, and stripping and insertion lengths. |
Conductor connection
Connection Method | Push-in connection |
Conductor cross section rigid | 0.5 mm² ... 1.5 mm² |
Conductor cross section flexible | 0.5 mm² ... 1.5 mm² |
Conductor cross section AWG | 20 ... 16 |
Stripping length | 8 mm |
I/O
Connection Method | Push-in connection |
Note on the connection method | Note the specification in the section Conductor cross sections, and stripping and insertion lengths. |
Conductor cross section, rigid | 0.5 mm² ... 1.5 mm² |
Conductor cross section, flexible | 0.5 mm² ... 1.5 mm² |
Conductor cross section AWG | 20 ... 16 |
Stripping length | 8 mm |
Ambient conditions
Ambient Temperature (Operation) | -35 °C ... 60 °C |
Degree of Protection | IP20 |
Degree of protection at installation location | min. IP54 |
Air pressure (operation) | 70 kPa ... 108 kPa |
Air pressure (storage/transport) | 66 kPa ... 108 kPa |
Ambient temperature (storage/transport) | -40 °C ... 85 °C |
Standards and Regulations
Protection class | III (IEC 61140-1) |
Air clearances and creepage distances
Air clearances and creepage distances | IEC 60664-1 |
Mounting
Mounting Type | DIN rail mounting |
Mounting Position | any |
Why Proax for Phoenix Contact 2702858?
Proax is an authorized distributor of Phoenix Contact 2702858 and one of Phoenix Contact's largest distributors in North America. Our highly skilled in-house technical team is ready to assist with any technical needs.
Have a question in mind? to help you get the right product as quickly as possible for your project. We're always here to help!
Short Lead Time
Highly Trained Staff
Live Chat
Technical Support
Local Inventory
60+ Years Experience
Additional Information
Pack Size | 1 |
Recommended
- Axioline F, Module d'entrée numérique, Sécurité fonctionnelle, PROFIsafe, destiné uniquement au raccordement sur des contrôleurs Phoenix Contact ou Siemens, Entrées TOR: 4 (avec affectation de deux canaux), 8 (avec affectation d'un canal), 24 V DC, connectique: 2, 3 ou 4 fils, indice de protection: IP20
- 2702120 - Axioline F, Temperature recording module, Analog inputs: 8 (for resistance temperature detectors), connection technology: 2-, 4-conductor (shielded), transmission speed in the local bus: 100 Mbps, measuring dynamics up to 8 Hz, degree of protection: IP20, including bus base module and Axioline F connectors
- 2701235 - Axioline F, Temperature recording module, Analog inputs: 8 (for resistance temperature detectors), connection technology: 2-, 3-, 4-conductor (shielded), transmission speed in the local bus: 100 Mbps, Extreme conditions version, degree of protection: IP20, including bus base module and Axioline F connectors
- 1035430 - Axioline F, Temperature recording module, Analog inputs: 4 (for resistance temperature detectors), connection technology: 2-, 3-, 4-conductor (shielded), transmission speed in the local bus: 100 Mbps, Extreme conditions version, degree of protection: IP20, including bus base module and Axioline F connectors
- 2688417 - Axioline F, Temperature recording module, Analog inputs: 8 (8 inputs for thermocouples or linear voltage, plus 1 input -5 V to +5 V), connection technology: 2-conductor (shielded, twisted pair), transmission speed in the local bus: 100 Mbps, degree of protection: IP20, including bus base module and Axioline F connectors
- 2702464 - Axioline F, Temperature recording module, Analog inputs: 8 (8 inputs for thermocouples or linear voltage, plus 1 input -5 V to +5 V), connection technology: 2-conductor (shielded, twisted pair), transmission speed in the local bus: 100 Mbps, Extreme conditions version, degree of protection: IP20, including bus base module and Axioline F connectors
- 2688598 - Axioline F, Temperature recording module, Analog inputs: 4 (4 inputs for thermocouples or linear voltage, plus 1 input -5 V to +5 V), connection technology: 2-conductor (shielded, twisted pair), transmission speed in the local bus: 100 Mbps, degree of protection: IP20, including bus base module and Axioline F connectors