Proax

Currency
0 Items
proax logo
Cart
Phoenix ContactOfficial Distributor

By Phoenix Contact

SKU
MPN
2701235
Weight
0.264 kg
This product is Not Cancellable/Not Returnable
Series AXL-F-RTD

AXL F RTD8 XC 1F - Temperature module

Axioline F, Temperature recording module, Analog inputs: 8 (for resistance temperature detectors), connection technology: 2-, 3-, 4-conductor (shielded), transmission speed in the local bus: 100 Mbps, Extreme conditions version, degree of protection: IP20, including bus base module and Axioline F connectors

  • 8 analog input channels for the connection of resistance temperature detectors (RTD)
  • 500 Ω and 5 kΩ linear inputs
  • Connection of sensors in 2-, 3-, and 4-conductor technology
  • Integrated, digital sensor linearization
  • Standardized measured value representation directly in °C, °F or Ω
  • Measured value display in 16-bit format or floating point format
  • Programmable filters
  • Short-circuit protected inputs
  • Temperature stability
  • Very high level of noise immunity
  • Low noise emission
  • Installation monitoring by means of “Channel scout” function
  • Can be used under extreme ambient conditions
  • Extended temperature range of -40 °C ... +70 °C (see “Tested successfully: use under extreme ambient conditions” in the data sheet)
  • Partially coated PCBs
  • Device rating plate stored
Technical Specifications

Dimensions

Width53.6 mm
Height126.1 mm
Depth54 mm
Note on dimensionsThe depth applies when a TH 35-7.5 DIN rail is used (in accordance with EN 60715).

Axioline F local bus

Number of interfaces2
Connection MethodBus base module
Transmission Speed100 Mbps

Module

Input address area16 Byte
Output address area16 Byte
Required parameter data 20 Byte
Required configuration data 6 Byte

Analog

Input nameAnalog inputs
Description of the inputInputs for resistive temperature sensors
Number of Inputs8 (for resistance temperature detectors)
Connection MethodPush-in connection
Connection technology2-, 3-, 4-conductor (shielded)
A/D converter resolution24 bit
Sensor types (RTD) that can be usedPt, Ni, KTY, Cu sensors
Data formatsIB IL, S7-compatible
Measured value representation16 bits (15 bits + sign bit)
Input filter time40 ms
Input filter time60 ms
Input filter time100 ms
Input filter time120 ms (adjustable)
Nominal value of the current sources1 mA (Pt 100, Ni 100, RLin 500 Ω; pulse current, the specification is valid during the sampling phase)
Nominal value of the current sources210 µA (P t1000, Ni 1000, RLin 5000 Ω; pulse current, the specification is valid during the sampling phase)
Differential non-linearitytyp. 1 ppm / ±0.0001 % (in all ranges)
Integral non-linearitytyp. 30 ppm / ±0.003 % (Pt 100)
Integral non-linearitytyp. 20 ppm / ±0.002 % (RLin 500 Ω)
Integral non-linearitytyp. 200 ppm / ±0.02 % (RLin 5000 Ω)
Linear resistance measuring range0 Ω ... 500 Ω
Linear resistance measuring range0 kΩ ... 5 kΩ
Protective circuitShort-circuit protection, overload protection of the inputs
Protective circuitTransient protection of inputs
Protective circuitTransient protection of sensor supplies

Product properties

Product familyAxioline F
Typeblock modular
Mounting Positionany (no temperature derating)
Scope of deliveryincluding bus base module and Axioline F connectors
Special PropertiesExtreme conditions version

Insulation characteristics

Overvoltage categoryII (IEC 60664-1, EN 60664-1)
Pollution degree2 (IEC 60664-1, EN 60664-1)

Potentials

Power consumptiontyp. 0.94 W (at UBus and UA (up to HW 01))
Power consumptiontyp. 0.59 W (at UBus and UA (from HW 02))
Power consumptionmax. 1.5 W (at UBus and UA (up to HW 01))
Power consumptionmax. 1.03 W (at UBus and UA (from HW 02))

Potentials: Axioline F local bus supply (UBus)

Supply Voltage5 V DC (via bus base module)
Current drawmax. 180 mA (up to HW 01)
Current drawmax. 85 mA (from HW 02)
Current drawtyp. 115 mA (up to HW 01)
Current drawtyp. 60 mA (from HW 02)
Power consumptionmax. 900 mW (up to HW 01)
Power consumptionmax. 425 mW (from HW 02)
Power consumptiontyp. 580 mW (up to HW 01)
Power consumptiontyp. 300 mW (from HW 02)

Potentials: Supply for analog modules (UA)

Supply Voltage24 V DC
Supply Voltage Range19.2 V DC ... 30 V DC (including all tolerances, including ripple)
Current drawmax. 25 mA
Current drawtyp. 15 mA (up to HW 01)
Current drawtyp. 12 mA (from HW 02)
Power consumptionmax. 0.6 W
Protective circuitSurge protection; electronic (35 V, 0.5 s)
Protective circuitReverse polarity protection; Polarity protection diode
Protective circuitTransient protection; Suppressor diode

Electrical isolation/isolation of the voltage ranges

Test voltage: 5 V supply of the local bus (UBus) / 24 V supply (I/Os)500 V AC, 50 Hz, 1 min.
Test voltage: 5 V supply of the local bus (UBus)/analog inputs500 V AC, 50 Hz, 1 min.
Test voltage: 5 V supply of the local bus (UBus) / functional ground500 V AC, 50 Hz, 1 min.
Test voltage: 24 V supply (I/O)/analog inputs500 V AC, 50 Hz, 1 min.
Test voltage: 24 V supply (I/O) / functional ground500 V AC, 50 Hz, 1 min.
Test voltage: Analog inputs/functional ground500 V AC, 50 Hz, 1 min.

Connection technology

Connection nameAxioline F connector
Note on the connection methodPlease observe the information provided on conductor cross sections in the “Axioline F: system and installation” user manual.

Conductor connection

Connection MethodPush-in connection
Conductor cross section rigid0.2 mm² ... 1.5 mm²
Conductor cross section flexible0.2 mm² ... 1.5 mm²
Conductor cross section AWG24 ... 16
Stripping length8 mm

Axioline F connector

Connection MethodPush-in connection
Note on the connection methodPlease observe the information provided on conductor cross sections in the “Axioline F: system and installation” user manual.
Conductor cross section, rigid0.2 mm² ... 1.5 mm²
Conductor cross section, flexible0.2 mm² ... 1.5 mm²
Conductor cross section AWG24 ... 16
Stripping length8 mm

Ambient conditions

Ambient Temperature (Operation)-25 °C ... 60 °C (Standard)
Ambient Temperature (Operation)-40 °C ... 70 °C (Extended, see section “Tested successfully: use under extreme ambient conditions” in the data sheet.)
Degree of ProtectionIP20
Air pressure (operation)70 kPa ... 106 kPa (up to 3000 m above sea level)
Air pressure (storage/transport)70 kPa ... 106 kPa (up to 3000 m above sea level)
Ambient temperature (storage/transport)-40 °C ... 85 °C
Permissible humidity (operation)5 % ... 95 % (non-condensing)
Permissible humidity (storage/transport)5 % ... 95 % (non-condensing)

Standards and Regulations

Protection classIII (IEC 61140, EN 61140, VDE 0140-1)

Mounting

Mounting TypeDIN rail mounting
Mounting Positionany (no temperature derating)
Accessories

Why Proax for Phoenix Contact AXL F RTD8 XC 1F?

Proax is an authorized distributor of Phoenix Contact AXL F RTD8 XC 1F and one of Phoenix Contact's largest distributors in North America. Our highly skilled in-house technical team is ready to assist with any technical needs.

Have a question in mind? to help you get the right product as quickly as possible for your project. We're always here to help!

Short Lead Time
Highly Trained Staff
Live Chat
Technical Support
Local Inventory
60+ Years Experience
Additional Information

Alternate NamesAXLFRTD8XC1F
Pack Size1
Recommended