Proax

Currency
0 Items
proax logo
Cart
Phoenix ContactOfficial Distributor

By Phoenix Contact

SKU
MPN
PSR-SPP-24-230UC/ESAM4/3X1/1X2
Weight
0.411 kg
This product has been discontinued and replaced with 2700525
Series PSR-SPP

PSR-SPP-24-230UC/ESAM4/3X1/1X2 - Safety relays

Safety relay for emergency stop and safety door monitoring up to SIL 3 or Cat. 4, PL e in accordance with EN ISO 13849, 1- or 2-channel operation, 3 enabling current paths, nominal input voltage: 24 V AC/DC ... 230 V AC/DC, plug-in Push-in terminal block

  • With inrush current reduction, therefore suitable for coupling to failsafe controllers (PSR-ESP4)
  • 1- and 2-channel control
  • With wide-range input (PSR-ESAM4/3X1)
Technical Specifications

Utilization restriction

EMC noteEMC: class A product, see manufacturer's declaration in the download area

Product properties

Product familyPSRclassic
ApplicationEmergency stop
ApplicationSafety door
ApplicationLight grid
Mechanical service lifeapprox. 107 cycles
Relay typeElectromechanical relay with force-guided contacts in accordance with IEC/EN 61810-3

Electrical properties

Maximum power dissipation for nominal condition2.88 W
Nominal operating mode100% operating factor

Air clearances and creepage distances between the power circuits

Rated Insulation Voltage250 V AC
Rated surge voltage/insulation6 kV/safe isolation, reinforced insulation and 6 kV between input circuits and output contact current paths (13/14, 23/24, 33/34), as well as between output contact current paths (13/14, 23/24, 33/34).

General

Input voltage range24 V AC/DC ... 230 V AC/DC
Input voltage range in reference to UN0.85 ... 1.1
Typical input current at UN120 mA (at 24 V DC)
Typical input current at UN20 mA (at 120 V AC)
Typical input current at UN10 mA (for 230 V AC)
Voltage at input/start and feedback circuitapprox. 24 V DC
Typical response time50 ms (manual start)
Typical response time60 ms (automatic start)
Typ. starting time with Us500 ms (when controlled via A1)
Typical release time20 ms (when controlled via S11/S12 and S21/S22)
Typical release time50 ms (at 24 V DC)
Typical release time110 ms (at 120 V AC)
Typical release time280 ms (for 230 V AC)
Concurrence
Recovery time1 s
Maximum switching frequency0.5 Hz
Protective circuitSurge protection; Suppressor diode and varistors
Max. permissible overall conductor resistance11 Ω
Operating voltage display1 x green LED
Status display2 x green LEDs

Output data

Contact switching type3 enabling current paths
Contact switching type1 signaling current path
Contact MaterialAgSnO2, + 0.2 µm Au
Maximum Switching Voltage250 V AC/DC
Minimum Switching Voltage10 V AC/DC
Limiting Continuous Current6 A (N/O contact / N/C contact)
Maximum Inrush Current6 A
Inrush current, minimum10 mA
Sq. Total current50 A2 (ITH2 = I12 + I22 + ... + IN2)
Interrupting rating (ohmic load) max.192 W (24 V DC, τ = 0 ms)
Interrupting rating (ohmic load) max.384 W (48 V DC, τ = 0 ms)
Interrupting rating (ohmic load) max.80 W (110 V DC, τ = 0 ms)
Interrupting rating (ohmic load) max.66 W (220 V DC, τ = 0 ms)
Interrupting rating (ohmic load) max.2000 VA (250 V AC, τ = 0 ms)
Maximum interrupting rating (inductive load)48 W (24 V DC, τ = 40 ms)
Maximum interrupting rating (inductive load)48 W (48 V DC, τ = 40 ms)
Maximum interrupting rating (inductive load)48 W (110 V DC, τ = 40 ms)
Maximum interrupting rating (inductive load)48 W (220 V DC, τ = 40 ms)
Switching capacity min.360 mW
Switching capacity (360/h cycles)4 A (24 V (DC13))
Switching capacity (360/h cycles)4 A (230 V (AC15))
Switching capacity (3600/h cycles)2.5 A (24 V (DC13))
Switching capacity (3600/h cycles)3 A (230 V (AC15))
Output fuse6 A gG NEOZED
Output fuseB6/C4A gL/gG automatic device

Connection technology

pluggableyes

Conductor connection

Connection MethodPush-in connection
Conductor cross section, rigid0.2 mm² ... 1.5 mm²
Conductor cross section, flexible0.2 mm² ... 1.5 mm²
Conductor cross section, flexible, with ferrule, with plastic sleeve0.25 mm² ... 1.5 mm² (only together with CRIMPFOX 6)
Conductor cross section flexible, with ferrule without plastic sleeve0.25 mm² ... 1.5 mm² (only together with CRIMPFOX 6)
Conductor cross section AWG24 ... 16
Stripping length8 mm

Dimensions

Width45 mm
Height112 mm
Depth114.5 mm

Material specifications

Coloryellow

Safety data

Stop category0

Safety data: EN ISO 13849

Category4
Performance level (PL)e

Safety data: IEC 61508 - High demand

Safety Integrity Level (SIL)3

Safety data: IEC 61508 - Low demand

Safety Integrity Level (SIL)3

Safety data: EN IEC 62061

Safety Integrity Level (SIL)3

Ambient conditions

Degree of ProtectionIP54
Degree of ProtectionIP20
Min. degree of protection of inst. locationIP54
Ambient Temperature (Operation)-20 °C ... 55 °C
Ambient temperature (storage/transport)-25 °C ... 85 °C
Maximum altitude≤ 2000 m (Above sea level)
Max. permissible humidity (storage/transport)75 % (on average, 85% infrequently, non-condensing)
Max. permissible relative humidity (operation)75 % (on average, 85% infrequently, non-condensing)
Shock15g
Vibration (Operation)10 Hz ... 150 Hz, 2g

Air clearances and creepage distances between the power circuits

Standards/regulationsDIN EN 50178/VDE 0160

Mounting

Mounting TypeDIN rail mounting
Mounting Positionany

Why Proax for Phoenix Contact 2981127?

Proax is an authorized distributor of Phoenix Contact 2981127 and one of Phoenix Contact's largest distributors in North America. Our highly skilled in-house technical team is ready to assist with any technical needs.

Have a question in mind? to help you get the right product as quickly as possible for your project. We're always here to help!

Short Lead Time
Highly Trained Staff
Live Chat
Technical Support
Local Inventory
60+ Years Experience
Additional Information

Pack Size1
Recommended

Not in stock

Request lead time or order—we'll ensure quick delivery

Phoenix Contact Availability