SKU
MPN
QUINT-DIODE/48DC/40
Weight
0.679 kg
Series QUINT-DIODE
QUINT-DIODE/48DC/40 - Redundancy module, with protective coating
QUINT-DIODE/48DC/40 redundancy module
Technical Specifications
DC operation
Input Voltage | 48 V DC (UN) |
Input Voltage | < 60 V DC (Umax) |
Input voltage range | 10 V DC ... 60 V DC |
Input voltage range DC | 10 V DC ... 60 V DC |
Voltage type of supply voltage | DC |
Reverse polarity protection | < yes120 V |
Nominal input current (IN) | 2x 20 A |
Nominal input current (IN) | 1x 40 A |
Maximum current Imax | 2x 19 A (6 mm² at 40°C) |
Maximum current Imax | 1x 39 A (6 mm² at 40°C) |
Maximum current Imax | 2x 16 A (6 mm² at 60°C) |
Maximum current Imax | 1x 32 A (6 mm² at 60°C) |
Maximum current Imax | 2x 27 A (10 mm² at 40°C) |
Maximum current Imax | 1x 54 A (10 mm² at 40°C) |
Maximum current Imax | 2x 21 A (10 mm² at 60°C) |
Maximum current Imax | 1x 43 A (10 mm² at 60°C) |
Maximum current Imax | 2x 30 A (16 mm² at 40 °C) |
Maximum current Imax | 1x 60 A (16 mm² at 40 °C) |
Maximum current Imax | 2x 24 A (16 mm² at 60°C) |
Maximum current Imax | 1x 48 A (16 mm² at 60°C) |
Nominal input current (IN) | 2x 20 A |
Nominal input current (IN) | 1x 40 A |
Maximum current Imax | 2x 17 A (6 mm² at 40°C for potentially explosive areas: Class I, Div. 2, Groups A, B, C, D; T4) |
Maximum current Imax | 1x 35 A (6 mm² at 40°C for potentially explosive areas: Class I, Div. 2, Groups A, B, C, D; T4) |
Maximum current Imax | 2x 14 A (6 mm² at 60°C for potentially explosive areas: Class I, Div. 2, Groups A, B, C, D; T4) |
Maximum current Imax | 1x 28 A (6 mm² at 60°C for potentially explosive areas: Class I, Div. 2, Groups A, B, C, D; T4) |
Maximum current Imax | 2x 24 A (10 mm² at 40°C for potentially explosive areas: Class I, Div. 2, Groups A, B, C, D; T4) |
Maximum current Imax | 1x 49 A (10 mm² at 40°C for potentially explosive areas: Class I, Div. 2, Groups A, B, C, D; T4) |
Maximum current Imax | 2x 19 A (10 mm² at 60°C for potentially explosive areas: Class I, Div. 2, Groups A, B, C, D; T4) |
Maximum current Imax | 1x 39 A (10 mm² at 60°C for potentially explosive areas: Class I, Div. 2, Groups A, B, C, D; T4) |
Maximum current Imax | 2x 27 A (16 mm² at 40°C for potentially explosive areas: Class I, Div. 2, Groups A, B, C, D; T4) |
Maximum current Imax | 1x 54 A (16 mm² at 40°C for potentially explosive areas: Class I, Div. 2, Groups A, B, C, D; T4) |
Maximum current Imax | 2x 22 A (16 mm² at 60°C for potentially explosive areas: Class I, Div. 2, Groups A, B, C, D; T4) |
Maximum current Imax | 1x 44 A (16 mm² at 60°C for potentially explosive areas: Class I, Div. 2, Groups A, B, C, D; T4) |
Transient surge protection | Transil diode |
Voltage drop, input/output | approx. 0.7 V |
Output data
Efficiency | > 97 % |
Nominal Output Voltage | 47.3 V DC (Input/output voltage drop of 48 V ... 0.7 V ) |
Nominal output current (IN) | 40 A |
Power loss nominal load max. | 28 W |
Connection in series | No |
Input
Connection Method | Screw connection |
Conductor cross section, rigid min. | 0.5 mm² |
Conductor cross section, rigid max. | 16 mm² |
Conductor cross section flexible min. | 0.5 mm² |
Conductor cross section flexible max. | 10 mm² |
Conductor cross section AWG min. | 20 |
Conductor cross section AWG max. | 6 |
Stripping length | 10 mm |
Screw thread | M4 |
Tightening torque, min | 1.2 Nm |
Tightening torque max | 1.5 Nm |
Output
Connection Method | Screw connection |
Conductor cross section, rigid min. | 0.5 mm² |
Conductor cross section, rigid max. | 16 mm² |
Conductor cross section flexible min. | 0.5 mm² |
Conductor cross section flexible max. | 10 mm² |
Conductor cross section AWG min. | 20 |
Conductor cross section AWG max. | 6 |
Stripping length | 10 mm |
Screw thread | M4 |
Tightening torque, min | 1.2 Nm |
Tightening torque max | 1.5 Nm |
Electrical properties
Insulation voltage output / PE | 1 kV |
Insulation voltage input / PE | 1 kV |
Product properties
Product family | QUINT DIODE |
LED | No |
Insulation characteristics
Protection class | II |
Degree of pollution | 2 |
Dimensions
Width | 62 mm |
Height | 84 mm |
Depth | 102 mm |
Horizontal pitch | 3.4 Div. |
Installation dimensions
Installation distance right/left | 5 mm / 5 mm |
Installation distance top/bottom | 50 mm / 50 mm |
Mounting
Mounting Type | DIN rail mounting |
Assembly instructions | alignable: horizontal 20 mm, vertical 50 mm |
Mounting Position | horizontal and vertical DIN rail NS 35, EN 60715 |
Material specifications
Housing Material | Metal |
Type of housing | AIMg (hood), GD-ZnAICu (cooling unit) |
Ambient conditions
Degree of Protection | IP20 |
Ambient Temperature (Operation) | -25 °C ... 70 °C (> 60 °C derating, -25 ... 60°C) |
Ambient temperature (storage/transport) | -40 °C ... 85 °C |
Max. permissible relative humidity (operation) | ≤ 95 % (at 25 °C, non-condensing) |
Shock | 30g, 18 ms in accordance with IEC 60068-2-27 |
Vibration (Operation) | 3 Hz ... 15 Hz, amplitude ±2.5 mm; 15 Hz ... 100 Hz, 2.3g according to IEC 60068-2-6 |
Standards and Regulations
Declaration of conformity in acc. with EN 60079-15 | II 3 G Ex nA II T4 X |
Standard – Electronic equipment for use in electrical power installations and their assembly into electrical power installations | EN 50178/VDE 0160 (PELV) |
Standard - Electrical safety | EN 60950-1/VDE 0805 (SELV) |
Approvals
UL approvals | UL/C-UL listed UL 508 |
UL approvals | UL/C-UL Recognized UL 60950-1 |
UL approvals | UL/C-UL Listed UL 1604 Class I, Division 2, Groups A, B, C, D |
Conformity/Approvals
ATEX | II 3 G Ex nA II T4 |
EMC data
Low Voltage Directive | Conformance with Low Voltage Directive 2014/35/EC |
EMC requirements for noise emission | EN 61000-6-3 |
EMC requirements for noise emission | EN 61000-6-4 |
EMC requirements for noise immunity | EN 61000-6-1 |
EMC requirements for noise immunity | EN 61000-6-2 |
Electromagnetic compatibility | Conformance with EMC Directive 2014/30/EU |
Noise emission | EN 55011 |
Why Proax for Phoenix Contact 2866585?
Proax is an authorized distributor of Phoenix Contact 2866585 and one of Phoenix Contact's largest distributors in North America. Our highly skilled in-house technical team is ready to assist with any technical needs.
Have a question in mind? to help you get the right product as quickly as possible for your project. We're always here to help!
Short Lead Time
Highly Trained Staff
Live Chat
Technical Support
Local Inventory
60+ Years Experience
Additional Information
Pack Size | 1 |
Recommended