Proax

Currency
0 Items
proax logo
Cart
Phoenix ContactOfficial Distributor

By Phoenix Contact

SKU
MPN
2866242
Weight
1.043 kg

QUINT-DC-UPS/24DC/40 - Uninterruptible power supply

Uninterruptible power supply 24 V/40 A. In the download area, there is a clearly arranged selection table available with load currents and buffer times, as well as charging times after buffer mode.

Technical Specifications

DC operation

Input Voltage24 V DC
Input voltage range22.5 V DC ... 30 V DC
Wide-range inputno
Input voltage range DC22.5 V DC ... 30 V DC
Voltage type of supply voltageDC
Buffer period5 min. (40 A)
Buffer period9 min. (40 A)
Current consumptionapprox. 0.1 A
Current consumption2.5 A (charging process)
Current consumption42.5 A (max.)
Fixed backup threshold< 22 V DC
Variable connect threshold(UIN - 1 V)/0.1 s
Input fuse50 A (slow-blow, internal)

Output data

Efficiency> 98 %
Nominal Output Voltage24 V DC (Normal operation: Uin- 0.5 V DC, buffer mode: 27.9 to 19.2 V DC)
Nominal output current (IN)40 A
Bridging time9 min.
Output Power960 W
Power dissipation20 W
Power dissipation30 W
Connection in parallelyes, for increasing the buffer period
Connection in seriesyes

Mains operation

Nominal Output Voltage24 V DC
Nominal output current (IN)40 A

Battery operation

Nominal Output Voltage24 V DC
Nominal output current (IN)40 A

Signal

Output descriptionPower OK

Signal: floating

Output descriptionAlarm
Maximum Switching Voltage≤ 30 V AC/DC
Continuous load current≤ 1 A
Output descriptionBattery Charge
Maximum Switching Voltage≤ 30 V AC/DC
Continuous load current≤ 1 A
Output descriptionBattery Mode
Maximum Switching Voltage≤ 30 V AC/DC
Continuous load current≤ 1 A

Energy storage

Nominal capacity range3.4 Ah ... 12 Ah
Battery module service life6 Years (20 °C)
Latest startup date (battery only)9 Months (20 °C ... 30 °C)
Latest startup date (battery only)6 Months (30 °C ... 40 °C)
Memory mediumexternal, battery 3.4 Ah / 7.2 Ah / 12 Ah
Network managementYes

Input

Connection MethodScrew connection
Conductor cross section, rigid min.0.5 mm²
Conductor cross section, rigid max.16 mm²
Conductor cross section flexible min.0.5 mm²
Conductor cross section flexible max.10 mm²
Conductor cross section AWG min.20
Conductor cross section AWG max.6
Stripping length10 mm
Screw threadM4

Output

Connection MethodScrew connection
Conductor cross section, rigid min.0.5 mm²
Conductor cross section, rigid max.16 mm²
Conductor cross section flexible min.0.5 mm²
Conductor cross section flexible max.10 mm²
Conductor cross section AWG min.20
Conductor cross section AWG max.6
Stripping length10 mm
Screw threadM4

Signal

Conductor cross section, rigid min.0.2 mm²
Conductor cross section, rigid max.4 mm²
Conductor cross section flexible min.0.2 mm²
Conductor cross section flexible max.2.5 mm²
Conductor cross section AWG min.24
Conductor cross section AWG max.12
Screw threadM3
Tightening torque, min0.5 Nm
Tightening torque max0.6 Nm

Signaling

Types of signalingLED
Operating voltage displayGreen LED

Signal output

Status displayLED "Power OK" green
Note on status displayPower OK: LED permanently lit

Signal output: floating

Status displayLED red
Note on status displayAlarm: LED permanently lit
Status displayLED flashing yellow
Note on status displayBattery charge: LED flashing
Status displayYellow LED
Note on status displayBattery mode: LED permanently lit

Electrical properties

Insulation voltage input/output2 kV (routine test)
Insulation voltage input/output4 kV (type test)

Product properties

MTBF (IEC 61709, SN 29500)> 500000 h

Insulation characteristics

Protection classII (in closed control cabinet)

Dimensions

Width66 mm
Height130 mm
Depth125 mm

Installation dimensions

Installation distance right/left5 mm / 5 mm
Installation distance top/bottom50 mm / 50 mm

Alternative assembly

Width122 mm
Height130 mm
Depth69 mm

Mounting

Mounting TypeDIN rail mounting
Assembly instructionsalignable: horizontally 0 mm, vertically 50 mm
Mounting Positionhorizontal DIN rail NS 35, EN 60715

Material specifications

Housing MaterialMetal
Type of housingAluNox (AlMg1)

Ambient conditions

Degree of ProtectionIP20
Ambient Temperature (Operation)-25 °C ... 70 °C
Ambient temperature (storage/transport)-40 °C ... 85 °C
Max. permissible relative humidity (operation)95 % (at 25 °C, non-condensing)

Standards and Regulations

Standard – Electronic equipment for use in electrical power installations and their assembly into electrical power installationsEN 50178/VDE 0160 (PELV)
Standard - Electrical safetyEN 60950-1/VDE 0805 (SELV)
Standard - Electrical safetyEN 61558-2-17
Standard - Safe isolationDIN VDE 0100-410
Standard - Safety of transformersEN 61558-2-17

Approvals

Shipbuilding approvalDNV GL (EMC A), ABS
UL approvalsUL/C-UL listed UL 508
UL approvalsUL/C-UL Recognized UL 60950-1

EMC data

Low Voltage DirectiveConformance with Low Voltage Directive 2014/35/EC
Noise immunityEN 61000-6-2:2005
Electromagnetic compatibilityConformance with EMC Directive 2014/30/EU
Noise emissionEN 55011 (EN 55022)

Why Proax for Phoenix Contact QUINT-DC-UPS/24DC/40?

Proax is an authorized distributor of Phoenix Contact QUINT-DC-UPS/24DC/40 and one of Phoenix Contact's largest distributors in North America. Our highly skilled in-house technical team is ready to assist with any technical needs.

Have a question in mind? to help you get the right product as quickly as possible for your project. We're always here to help!

Short Lead Time
Highly Trained Staff
Live Chat
Technical Support
Local Inventory
60+ Years Experience
Additional Information

Alternate NamesQUINTDCUPS24DC40
Pack Size1
Recommended

Available for order