Official Distributor
SKU
MPN
ILC 131 ETH
Weight
0.378 kg
Series ILC
ILC 131 ETH - Controller
The Inline controller offers the option of communicating via PROFINET and Modbus/TCP. Programming is carried out using PC Worx Express or PC Worx (IEC 61131-3).
- Memory extendable by up to 2 GB via plug-in SD card
- Free engineering with PC Worx Express (IEC 61131-3)
- Complete INTERBUS master (4096 I/O points)
- PROFINET-Device
- Modbus/TCP-Client
- Integrated FTP and HTML5 web server
- Numerous protocols supported such as: HTTP, FTP, SNTP, SNMP, SMTP, SQL, MySQL, etc.
Technical Specifications
Utilization restriction
CCCex note | Use in potentially explosive areas is not permitted in China. |
Product properties
Product family | Inline-Controller |
Type | modular |
Display
Diagnostics display | No |
System properties
Processor | Altera Nios® II 64 MHz |
Retentive data storage | 8 kByte (NVRAM) |
IEC 61131 runtime system
Program Memory | 192 kByte |
Data storage system | 192 kByte |
Number of control tasks | 8 |
INTERBUS-Master
Amount of Process Data | max. 4096 bit (INTERBUS) |
Number of supported devices | max. 63 |
Number of local bus devices that can be connected | max. 63 (observe current consumption) |
Number of devices with parameter channel | max. 8 |
Modbus/TCP-Client
Amount of Process Data | max. 8192 bit (internal Modbus /TCP client) |
Number of Modbus/TCP clients | max. 4 later than FW 4.42 |
PROFINET
Device function | PROFINET device |
Specification | 2.2 |
Device ID | 007Dhex / 125dez |
Vendor ID | 00B0hex / 176dez |
Function
Diagnostics display | No |
Controller redundancy | No |
Safety function | No |
Functionality
Programming languages supported | Instruction list (IL) |
Programming languages supported | Symbolic flowchart (SFC) |
Programming languages supported | Ladder diagram (LD) |
Programming languages supported | Function block diagram (FBD) |
Programming languages supported | Structured text (ST) |
System requirements
Engineering tool | PC Worx |
Engineering tool | PC Worx Express |
Configuration tool | Config+ Version 1.01 or later |
Diagnostics tool | DIAG+ |
Runtime system | eCLR |
Application interface | OPC |
Electrical properties
Transmission medium | Copper |
Real-time clock
Realtime Clock | Yes |
Description realtime clock | integrated (rechargeable battery buffered) |
Potentials: 24 V supply UILC
Supply Voltage | 24 V DC -15 % / +20 % (in accordance with EN 61131-2) |
Supply Voltage Range | 19.2 V DC ... 30 V DC |
Current draw | 80 mA (without connected I/O terminal blocks) |
Potentials: 7.5 V communications power UL (potential jumper)
Supply Voltage | 7.5 V DC ±5 % |
Potentials: 24 V analog supply UANA (potential jumper)
Supply Voltage | 24 V DC -15 % / +20 % |
Supply Voltage Range | 19.2 V DC ... 30 V DC (including all tolerances, including ripple) |
Potentials: 24 V main supply UM
Supply Voltage | 24 V DC -15 % / +20 % (in accordance with EN 61131-2) |
Supply Voltage Range | 19.2 V DC ... 30 V DC (including all tolerances, including ripple) |
Current draw | max. 8 A DC |
Current draw | 6 mA (without sensors) |
Potentials: 24 V segment supply US
Supply Voltage | 24 V DC -15 % / +20 % (in accordance with EN 61131-2) |
Supply Voltage Range | 19.2 V DC ... 30 V DC (including all tolerances, including ripple) |
Current draw | max. 8 A DC |
Current draw | 10 mA (without actuators) |
Digital:
Input name | Digital inputs |
Description of the input | EN 61131-2 type 1 NPN/PNP |
Number of Inputs | 8 |
Cable Length | max. 30 m |
Connection Method | Inline potential distributor |
Connection technology | 2-, 3-, 4-conductor |
Input voltage range | -0.5 V ... 30 V |
Input voltage range "0" signal | -0.5 V ... 5 V |
Input voltage range "1" signal | 15 V ... 30 V |
Nominal input current at UIN | typ. 7 mA |
Nominal input current at UIN | max. 15 mA |
Input filter time | typ. 5 ms (Signal change 01) |
Input filter time | typ. 5 ms () |
Output name | Digital outputs |
Connection Method | Spring-cage connection |
Connection technology | 2-, 3-, 4-conductor |
Number of Outputs | 4 |
Maximum Output Current per channel | 500 mA |
Maximum output current per module / terminal block | 2 A |
Nominal load, lamp | 12 W |
Nominal load, ohmic | 12 W |
Inline connector
Connection Method | Spring-cage connection |
Conductor cross section, rigid | 0.08 mm² ... 1.5 mm² |
Conductor cross section, flexible | 0.08 mm² ... 1.5 mm² |
Conductor cross section AWG | 28 ... 16 |
Interfaces
Web server | yes |
Ethernet
Bus system | RJ45 |
Number of interfaces | 1 |
Connection Method | RJ45 jack |
Transmission Speed | 10/100 Mbps |
No. of channels | 1 |
INTERBUS local bus (master)
Number of interfaces | 1 |
Connection Method | Inline data jumper |
Transmission Speed | 500 kBaud / 2 MBaud (can be switched) |
Parameterization/operation/diagnostics
Bus system | RS-232 |
Number of interfaces | 1 |
Connection Method | 6-pos. MINI DIN socket (PS/2) |
Transmission Speed | max. 115.2 kbps |
Transmission physics | Copper |
No. of channels | 1 |
Dimensions
Width | 80 mm |
Height | 119.8 mm |
Depth | 71.5 mm |
Material specifications
Color | green |
Ambient conditions
Degree of Protection | IP20 |
Ambient Temperature (Operation) | -25 °C ... 55 °C |
Ambient temperature (storage/transport) | -25 °C ... 85 °C |
Permissible humidity (operation) | 10 % ... 95 % (according to DIN EN 61131-2) |
Permissible humidity (storage/transport) | 10 % ... 95 % (according to DIN EN 61131-2) |
Shock | 25g, Criterion 1, according to IEC 60068-2-27 |
Vibration (Operation) | 5g |
Air pressure (operation) | 70 kPa ... 106 kPa (up to 3000 m above sea level) |
Air pressure (storage/transport) | 70 kPa ... 106 kPa (up to 3000 m above sea level) |
Resistance to gases that may endanger the functions, in acc. with DIN 40046-36, DIN 40046-37 | Sulfur dioxide (SO2) 10 ±0.3 ppm (test duration: 10 days), hydrogen sulfide (H2S) 1 ±0.3 ppm (test duration: 4 days), both at 25°C and with 75% humidity |
EMC data
Conformance with EMC directives | Immunity test in accordance with EN IEC 61000-6-2 Electrostatic discharge (ESD)IEC 61000-4-2 Criterion B, ±6 kV contact discharge, ±8 kV air discharge |
Conformance with EMC directives | Immunity test in accordance with EN IEC 61000-6-2 Electromagnetic fieldsIEC 61000-4-3 Criterion A, Field intensity: 10 V/m |
Conformance with EMC directives | Immunity test in accordance with EN IEC 61000-6-2 Fast transients (burst)IEC 61000-4-4 Criterion A, all interfaces ±1 kVCriterion B, all interfaces ±2 kV |
Conformance with EMC directives | Immunity test in accordance with EN IEC 61000-6-2 Transient overvoltage (surge)IEC 61000-4-5 Criterion B; DC supply lines: ±0.5 kV/±1.0 kV (symmetrical/asymmetrical), fieldbus cable shielding: ±1.0 kV |
Conformance with EMC directives | Immunity test in accordance with EN IEC 61000-6-2 Conducted interferenceIEC 61000-4-6 Criterion A, Test voltage 10 V |
Conformance with EMC directives | Noise emission test in accordance with EN IEC 61000-6-4 Class A |
Electromagnetic compatibility | Conformance with EMC Directive 2014/30/EU |
Mounting
Mounting Type | DIN rail mounting |
Accessories
Why Proax for Phoenix Contact 2700973?
Proax is an authorized distributor of Phoenix Contact 2700973 and one of Phoenix Contact's largest distributors in North America. Our highly skilled in-house technical team is ready to assist with any technical needs.
Have a question in mind? to help you get the right product as quickly as possible for your project. We're always here to help!
Short Lead Time
Highly Trained Staff
Live Chat
Technical Support
Local Inventory
60+ Years Experience
Additional Information
Pack Size | 1 |
Recommended
- ILC 131 STARTERKIT, Test the highly communicative ILC 131 ETH high-performance controller. Small to medium function units can be automated inexpensively using this high-performance controller. The high-performance controller features modular expansion, easy programming, and high performance. We have compiled this starter kit so that you can try out the capabilities of the ILC 131 ETH for yourself. It has digital and analog output and input terminals as well as simulation modules. In addition, example projects for PC WORX EXPRESS and the web server are available to the user.
- ILC 130 starter kit including ILC 130 ETH, analog input AI module, control panel, power supply unit as well as accessories and cable with set up test applicationInline Controller with Ethernet interface for coupling to other controllers and systems, with programming options according to IEC 61131-3, complete with plug and labeling field.Inline, Analog input terminal, Analog inputs: 2, 0 V ... 10 V, -10 V ... 10 V, 0 mA ... 20 mA, 4 mA ... 20 mA, -20 mA ... 20 mA, connection method: 2-wire, transmission speed in the local bus 500 kbps, degree of protection IP20, including Inline connector and labeling fieldVARIOFACE switch module, with COMBICON connector, for simulation, for 8 signals, for mounting DIN rail NS 35PC WORX EXPRESS is a piece of easy-to-operate engineering software. Class 100 and class 1000 modular small-scale controllers as well as the PC WORX SRT software controller with IEC-61131 programming languages ST and LD are supported. Free programming version w
- ILC 130 SBT starter kit including ILC 130 ETH, LPSDO and PSDI SafetyBridge modules, control panel, power supply unit, and accessories with pre-configured safety applicationInline Controller with Ethernet interface for coupling to other controllers and systems, with programming options according to IEC 61131-3, complete with plug and labeling field.Safety-related digital output module, IP20 protection, for the SafetyBridge system. The module has four safe digital outputs with two-channel occupancy or 8 safe digital outputs with single-channel occupancySafety-related digital input module, IP20 protection, for the SafetyBridge, INTERBUS-Safety, and PROFIsafe system. The module has 4 safe digital inputs for two-channel assignment or 8 safe digital inputs for single-channel assignment.VARIOFACE switch module, with COMBICON connector, for simulation, for 8 signals, for mounting DIN rail NS 35
- The ILC 150 ETH CONSTRUCTION KIT consists of a ILC 150 ETH with integrated Web/FTP server, OPC and INTERBUS Master.It also includes I/O modules with analog outputs and inputs, a 24 V power supply unit and the PC WORX EXPRESS development environment.Inline Controller with Ethernet interface for coupling to other controllers and systems, with programming options according to IEC 61131-3, complete with plug and labeling field.Inline, Analog output terminal, Analog output: 1, 0 V ... 10 V, connection method: 2-wire, transmission speed in the local bus 500 kbps, degree of protection IP20, including Inline connector and labeling fieldInline, Analog input terminal, Analog inputs: 2, 0 V ... 10 V, -10 V ... 10 V, 0 mA ... 20 mA, 4 mA ... 20 mA, -20 mA ... 20 mA, connection method: 2-wire, transmission speed in the local bus 500 kbps, degree of protection IP20, including Inline connector and labeling fieldDIN rail power supply unit 24 V DC/1.5 A, primary-switched mode, low-pr
- ILC 150 starter kit including ILC 150 PROFINET-Controller, bus terminal modules, I/O modules, control panel, power supply as well as accessories and cables for setting up a test applicationInline Controller with Ethernet interface for coupling to other controllers and systems, with programming options according to IEC 61131-3, complete with plug and labeling field.Inline, Analog output terminal, Analog output: 1, 0 V ... 10 V, connection method: 2-wire, transmission speed in the local bus 500 kbps, degree of protection IP20, including Inline connector and labeling fieldInline, Analog input terminal, Analog inputs: 2, 0 V ... 10 V, -10 V ... 10 V, 0 mA ... 20 mA, 4 mA ... 20 mA, -20 mA ... 20 mA, connection method: 2-wire, transmission speed in the local bus 500 kbps, degree of protection IP20, including Inline connector and labeling fieldDIN rail power supply unit 24 V DC/1.5 A, primary-switched mode, low-profile design