Proax

Currency
0 Items
proax logo
Cart
Phoenix ContactOfficial Distributor

By Phoenix Contact

SKU
MPN
ILC 191 ETH 2TX
Weight
0.374 kg
Series ILC

ILC 191 ETH 2TX - Controller

The Inline controller offers the option of communicating via PROFINET and Modbus/TCP. Programming is carried out using PC Worx Express or PC Worx (IEC 61131-3).

  • Memory extendable by up to 2 GB via plug-in SD card
  • Free engineering with PC Worx Express (IEC 61131-3)
  • Complete INTERBUS master (4096 I/O points)
  • PROFINET-Device
  • Modbus/TCP-Client
  • Integrated FTP and HTML5 web server
  • Numerous protocols supported such as: HTTP, FTP, SNTP, SNMP, SMTP, SQL, MySQL, etc.
Technical Specifications

Utilization restriction

CCCex noteUse in potentially explosive areas is not permitted in China.

Product properties

Product familyInline-Controller
Typemodular

Display

Diagnostics displayNo

System properties

ProcessorAltera Nios® II 64 MHz
Clock frequency64 MHz
Retentive data storage48 kByte (NVRAM)

IEC 61131 runtime system

Program Memory1 Mbyte
Data storage system1 Mbyte
Number of control tasks8

INTERBUS-Master

Amount of Process Datamax. 4096 bit (INTERBUS)
Number of supported devicesmax. 128
Number of local bus devices that can be connectedmax. 63 (observe current consumption)
Number of devices with parameter channelmax. 24
Number of supported branch terminals with remote bus branchmax. 3

Modbus/TCP-Client

Amount of Process Datamax. 32768 bit (internal Modbus /TCP client)
Number of Modbus/TCP clientsmax. 16 later than FW 4.42

PROFINET

Device functionPROFINET device
Specification2.2
Vendor ID00B0hex / 176dez

Function

Diagnostics displayNo
Controller redundancyNo
Safety functionNo

Functionality

Programming languages supportedInstruction list (IL)
Programming languages supportedSymbolic flowchart (SFC)
Programming languages supportedLadder diagram (LD)
Programming languages supportedFunction block diagram (FBD)
Programming languages supportedStructured text (ST)

System requirements

Engineering toolPC Worx
Engineering toolPC Worx Express
Configuration toolConfig+ Version 1.01 or later
Diagnostics toolDIAG+
Runtime systemeCLR
Application interfaceOPC

Electrical properties

Transmission mediumCopper

Real-time clock

Realtime ClockYes
Description realtime clockintegrated (rechargeable battery buffered)

Potentials: 24 V supply UILC

Supply Voltage24 V DC -15 % / +20 % (in accordance with EN 61131-2)
Supply Voltage Range19.2 V DC ... 30 V DC
Current draw80 mA (without connected I/O terminal blocks)

Potentials: 7.5 V communications power UL (potential jumper)

Supply Voltage7.5 V DC ±5 %

Potentials: 24 V analog supply UANA (potential jumper)

Supply Voltage24 V DC -15 % / +20 %
Supply Voltage Range19.2 V DC ... 30 V DC (including all tolerances, including ripple)

Potentials: 24 V main supply UM

Supply Voltage24 V DC -15 % / +20 % (in accordance with EN 61131-2)
Supply Voltage Range19.2 V DC ... 30 V DC (including all tolerances, including ripple)
Current drawmax. 8 A DC
Current draw6 mA (without sensors)

Potentials: 24 V segment supply US

Supply Voltage24 V DC -15 % / +20 % (in accordance with EN 61131-2)
Supply Voltage Range19.2 V DC ... 30 V DC (including all tolerances, including ripple)
Current drawmax. 8 A DC
Current draw10 mA (without actuators)

Digital:

Input nameDigital inputs
Description of the inputEN 61131-2 type 1 NPN/PNP
Number of Inputs8
Cable Lengthmax. 30 m
Connection MethodInline potential distributor
Connection technology2-, 3-, 4-conductor
Input voltage range-0.5 V ... 30 V
Input voltage range "0" signal-0.5 V ... 5 V
Input voltage range "1" signal15 V ... 30 V
Nominal input current at UINtyp. 7 mA
Nominal input current at UINmax. 15 mA
Input filter timetyp. 5 ms (Signal change 01)
Input filter timetyp. 5 ms ()
Output nameDigital outputs
Connection MethodSpring-cage connection
Connection technology2-, 3-, 4-conductor
Number of Outputs4
Maximum Output Current per channel500 mA
Maximum output current per module / terminal block2 A
Nominal load, lamp12 W
Nominal load, ohmic12 W
Behavior with inductive overloadOutput can be destroyed

Inline connector

Connection MethodSpring-cage connection
Conductor cross section, rigid0.08 mm² ... 1.5 mm²
Conductor cross section, flexible0.08 mm² ... 1.5 mm²
Conductor cross section AWG28 ... 16

Interfaces

Web serveryes

Ethernet

Bus systemRJ45
Number of interfaces2
Connection MethodRJ45 jack
Transmission Speed10/100 Mbps
No. of channels2

INTERBUS local bus (master)

Number of interfaces1
Connection MethodInline data jumper
Transmission Speed500 kBaud / 2 MBaud (can be switched)

Parameterization/operation/diagnostics

Bus systemRS-232
Number of interfaces1
Connection Method6-pos. MINI DIN socket (PS/2)
Transmission Speedmax. 115.2 kbps
Transmission physicsCopper
No. of channels1

Dimensions

Width80 mm
Height119.8 mm
Depth71.5 mm

Material specifications

Colorgreen

Ambient conditions

Degree of ProtectionIP20
Ambient Temperature (Operation)-25 °C ... 55 °C
Ambient temperature (storage/transport)-25 °C ... 85 °C
Permissible humidity (operation)10 % ... 95 % (according to DIN EN 61131-2)
Permissible humidity (storage/transport)10 % ... 95 % (according to DIN EN 61131-2)
Shock25g, Criterion 1, according to IEC 60068-2-27
Vibration (Operation)5g
Air pressure (operation)70 kPa ... 106 kPa (up to 3000 m above sea level)
Air pressure (storage/transport)70 kPa ... 106 kPa (up to 3000 m above sea level)
Resistance to gases that may endanger the functions, in acc. with DIN 40046-36, DIN 40046-37Sulfur dioxide (SO2) 10 ±0.3 ppm (test duration: 10 days), hydrogen sulfide (H2S) 1 ±0.3 ppm (test duration: 4 days), both at 25°C and with 75% humidity

EMC data

Conformance with EMC directivesImmunity test in accordance with EN IEC 61000-6-2 Electrostatic discharge (ESD)IEC 61000-4-2 Criterion B, ±6 kV contact discharge, ±8 kV air discharge
Conformance with EMC directivesImmunity test in accordance with EN IEC 61000-6-2 Electromagnetic fieldsIEC 61000-4-3 Criterion A, Field intensity: 10 V/m
Conformance with EMC directivesImmunity test in accordance with EN IEC 61000-6-2 Fast transients (burst)IEC 61000-4-4 Criterion A, all interfaces ±1 kVCriterion B, all interfaces ±2 kV
Conformance with EMC directivesImmunity test in accordance with EN IEC 61000-6-2 Transient overvoltage (surge)IEC 61000-4-5 Criterion B; DC supply lines: ±0.5 kV/±1.0 kV (symmetrical/asymmetrical), fieldbus cable shielding: ±1.0 kV
Conformance with EMC directivesImmunity test in accordance with EN IEC 61000-6-2 Conducted interferenceIEC 61000-4-6 Criterion A, Test voltage 10 V
Conformance with EMC directivesNoise emission test in accordance with EN 61000-6-4/IEC 61000-6-4 Class A
Electromagnetic compatibilityConformance with EMC Directive 2014/30/EU

Mounting

Mounting TypeDIN rail mounting
Accessories

Why Proax for Phoenix Contact 2700976?

Proax is an authorized distributor of Phoenix Contact 2700976 and one of Phoenix Contact's largest distributors in North America. Our highly skilled in-house technical team is ready to assist with any technical needs.

Have a question in mind? to help you get the right product as quickly as possible for your project. We're always here to help!

Short Lead Time
Highly Trained Staff
Live Chat
Technical Support
Local Inventory
60+ Years Experience
Additional Information

Pack Size1
Recommended

Available for order

Phoenix Contact Availability