Official Distributor
SKU
MPN
ILC 131 STARTERKIT
Weight
4.44 kg
Series ILC
ILC 131 STARTERKIT - Starter kit
ILC 131 starter kit incl. ILC 131 ETH, control panel, power supply unit, plus accessories and cables with test application set up
- Integrated I/Os: 8/4
- Processing time per 1000 instructions: 90 µs (bit data types), 1.7 ms (mixed data types)
- Program memory/data storage: 192 kB/192 kB
- Retentive data storage: 8 kB
- Supply voltage: 24 V DC
Technical Specifications
Product properties
Product family | Inline |
Type | Inline format with alignable I/Os |
System properties
Retentive data storage | 8 kByte (NVRAM) |
IEC 61131 runtime system
Program Memory | 192 kByte |
Data storage system | 192 kByte |
Number of control tasks | 8 |
INTERBUS-Master
Amount of Process Data | max. 4096 bit (INTERBUS) |
Number of supported devices | max. 63 |
Number of devices with parameter channel | max. 8 |
Modbus/TCP-Client
Amount of Process Data | max. 8192 bit (internal Modbus /TCP client) |
Number of Modbus/TCP clients | max. 4 later than FW 4.42 |
PROFINET
Device function | PROFINET device |
Functionality
Programming languages supported | Programming in acc. with IEC 61131-3 |
System requirements
Engineering tool | PC Worx |
Engineering tool | PC Worx Express |
Configuration tool | Config+ Version 1.01 or later |
Diagnostics tool | DIAG+ |
Runtime system | eCLR |
Application interface | OPC |
Real-time clock
Description realtime clock | integrated (rechargeable battery buffered) |
Potentials
Supply Voltage | 7.5 V DC ±5 % |
Supply Voltage | 24 V DC -15 % / +20 % |
Supply Voltage | 24 V DC -15 % / +20 % (in accordance with EN 61131-2) |
Current draw | max. 8 A DC |
Supply Voltage | 24 V DC -15 % / +20 % (in accordance with EN 61131-2) |
Current draw | max. 8 A DC |
Analog:
Number of Inputs | 2 |
Digital:
Input name | Digital inputs |
Description of the input | EN 61131-2 type 1 NPN/PNP |
Number of Inputs | 8 |
Connection Method | Inline potential distributor |
Connection technology | 2-, 3-, 4-conductor |
Output name | Digital outputs |
Connection Method | Spring-cage connection |
Connection technology | 2-, 3-, 4-conductor |
Mounting
Mounting Type | DIN rail mounting |
Why Proax for Phoenix Contact 2701835?
Proax is an authorized distributor of Phoenix Contact 2701835 and one of Phoenix Contact's largest distributors in North America. Our highly skilled in-house technical team is ready to assist with any technical needs.
Have a question in mind? to help you get the right product as quickly as possible for your project. We're always here to help!
Short Lead Time
Highly Trained Staff
Live Chat
Technical Support
Local Inventory
60+ Years Experience
Additional Information
Pack Size | 1 |
Recommended
- ILC 130 starter kit including ILC 130 ETH, analog input AI module, control panel, power supply unit as well as accessories and cable with set up test applicationInline Controller with Ethernet interface for coupling to other controllers and systems, with programming options according to IEC 61131-3, complete with plug and labeling field.Inline, Analog input terminal, Analog inputs: 2, 0 V ... 10 V, -10 V ... 10 V, 0 mA ... 20 mA, 4 mA ... 20 mA, -20 mA ... 20 mA, connection method: 2-wire, transmission speed in the local bus 500 kbps, degree of protection IP20, including Inline connector and labeling fieldVARIOFACE switch module, with COMBICON connector, for simulation, for 8 signals, for mounting DIN rail NS 35PC WORX EXPRESS is a piece of easy-to-operate engineering software. Class 100 and class 1000 modular small-scale controllers as well as the PC WORX SRT software controller with IEC-61131 programming languages ST and LD are supported. Free programming version w
- ILC 130 SBT starter kit including ILC 130 ETH, LPSDO and PSDI SafetyBridge modules, control panel, power supply unit, and accessories with pre-configured safety applicationInline Controller with Ethernet interface for coupling to other controllers and systems, with programming options according to IEC 61131-3, complete with plug and labeling field.Safety-related digital output module, IP20 protection, for the SafetyBridge system. The module has four safe digital outputs with two-channel occupancy or 8 safe digital outputs with single-channel occupancySafety-related digital input module, IP20 protection, for the SafetyBridge, INTERBUS-Safety, and PROFIsafe system. The module has 4 safe digital inputs for two-channel assignment or 8 safe digital inputs for single-channel assignment.VARIOFACE switch module, with COMBICON connector, for simulation, for 8 signals, for mounting DIN rail NS 35
- ILC 150 starter kit including ILC 150 PROFINET-Controller, bus terminal modules, I/O modules, control panel, power supply as well as accessories and cables for setting up a test applicationInline Controller with Ethernet interface for coupling to other controllers and systems, with programming options according to IEC 61131-3, complete with plug and labeling field.Inline, Analog output terminal, Analog output: 1, 0 V ... 10 V, connection method: 2-wire, transmission speed in the local bus 500 kbps, degree of protection IP20, including Inline connector and labeling fieldInline, Analog input terminal, Analog inputs: 2, 0 V ... 10 V, -10 V ... 10 V, 0 mA ... 20 mA, 4 mA ... 20 mA, -20 mA ... 20 mA, connection method: 2-wire, transmission speed in the local bus 500 kbps, degree of protection IP20, including Inline connector and labeling fieldDIN rail power supply unit 24 V DC/1.5 A, primary-switched mode, low-profile design
- The ILC 150 ETH CONSTRUCTION KIT consists of a ILC 150 ETH with integrated Web/FTP server, OPC and INTERBUS Master.It also includes I/O modules with analog outputs and inputs, a 24 V power supply unit and the PC WORX EXPRESS development environment.Inline Controller with Ethernet interface for coupling to other controllers and systems, with programming options according to IEC 61131-3, complete with plug and labeling field.Inline, Analog output terminal, Analog output: 1, 0 V ... 10 V, connection method: 2-wire, transmission speed in the local bus 500 kbps, degree of protection IP20, including Inline connector and labeling fieldInline, Analog input terminal, Analog inputs: 2, 0 V ... 10 V, -10 V ... 10 V, 0 mA ... 20 mA, 4 mA ... 20 mA, -20 mA ... 20 mA, connection method: 2-wire, transmission speed in the local bus 500 kbps, degree of protection IP20, including Inline connector and labeling fieldDIN rail power supply unit 24 V DC/1.5 A, primary-switched mode, low-pr