Proax

Currency
0 Items
proax logo
Cart
Phoenix ContactOfficial Distributor

By Phoenix Contact

SKU
MPN
2910105
Series UNO2-PS

UNO2-PS/1AC/24DC/480W - Power supply unit

Primary-switched power supply unit, UNO POWER, Screw connection, DIN rail mounting, input: 1-phase, output: 24 V DC / 20 A, adjustable from 24 V DC ... 28 V DC

  • Save space in the control cabinet, thanks to an extremely narrow overall width of just 59 mm
  • Save energy, thanks to a high degree of efficiency
  • Outdoor installation possible, with a wide temperature range of -25°C … +70°C
  • Simple output voltage monitoring, thanks to the floating DC OK relay contact
Technical Specifications

AC operation

Supply system configurationStar network (TN, TT, IT (PE))
Nominal input voltage range100 V AC ... 240 V AC
Input voltage range100 V AC ... 240 V AC -15 % ... +10 %
Derating< 90 V AC (1 %/V)
Typical national grid voltage120 V AC
Typical national grid voltage230 V AC
Voltage type of supply voltageAC
Inrush Currenttyp. 15 A (at 25 °C)
Inrush current integral (I2t)< 1 A2s
Frequency range (fN)50 Hz ... 60 Hz ±10 %
Mains buffering timetyp. 17 ms (120 V AC)
Mains buffering timetyp. 18 ms (230 V AC)
Current consumption5.4 A (100 V AC)
Current consumption4.4 A (120 V AC)
Current consumption2.3 A (230 V AC)
Current consumption2.2 A (240 V AC)
Protective circuitTransient surge protection; Varistor, gas-filled surge arrester
Switch-on timetyp. 1 s
Device mains fuse8 A internal (device protection), fast-blow
Recommended breaker for input protection10 A ... 16 A (Characteristic B, C, D, K or comparable)
Discharge current to PE< 3.5 mA

Output data

Efficiencytyp. 93 % (120 V AC)
Efficiencytyp. 94.6 % (230 V AC)
Nominal Output Voltage24 V DC
Setting range of the output voltage (USet)24 V DC ... 28 V DC (> 24 V DC, constant capacity restricted)
Nominal output current (IN)20 A
Short-circuit-proofyes
No-load proofyes
Derating55 °C ... 70 °C
Crest factortyp. 1.667 (120 V AC)
Crest factortyp. 1.75 (230 V AC)
Output power (PN)480 W
Connection in parallelyes, for redundancy
Connection in seriesyes, for increased output voltage
Feedback voltage resistance≤ 35 V DC
Protection against overvoltage at the output (OVP)≤ 35 V DC
Residual rippletyp. 70 mVPP (with nominal values)
Control deviation< 1 % (change in load, static 10 % ... 90 %)
Control deviation< 3 % (change in load, dynamic 10 % ... 90 %)
Control deviation< 0.1 % (change in input voltage ±10 %)
Rise time< 1 s (UOut = 10 % ... 90 %)
Minimum no-load power dissipation< 2.9 W (120 V AC)
Maximum no-load power dissipation< 3 W (230 V AC)
Minimum nominal load power dissipation< 37 W (120 V AC)
Power loss nominal load max.< 28 W (230 V AC)

Signal relay 13/14

Connection level3.x
Connection labeling3.1 (13), 3.2 (14)
Switch contact (floating)OptoMOS
Switching voltagemax. 30 V AC/DC
Switching voltagemax. 60 V DC
Current carrying capacitymax. 50 mA
State conditionUOUT > 0,9 x UN (Contact closed)
State conditionUOUT < 0,9 x UN (Contact open)

Input

Position1.x
Identification1.1 (), 1.2 (L), 1.3 (N)

Conductor connection

Connection MethodScrew connection
rigid0.2 mm² ... 6 mm²
flexible0.2 mm² ... 4 mm²
flexible with ferrule without plastic sleeve0.25 mm² ... 4 mm²
flexible with ferrule with plastic sleeve0.25 mm² ... 4 mm²
rigid (AWG)24 ... 10 (Cu)
Stripping length8 mm
Tightening torque0.5 Nm ... 0.6 Nm
Tightening torque4 lbf-in. ... 5 lbf-in.
Drive form screw headSlotted L

Output

Position2.x
Identification2.1, 2.2 (+), 2.3, 2.4 (-)

Conductor connection

Connection MethodScrew connection
rigid0.2 mm² ... 6 mm²
flexible0.2 mm² ... 4 mm²
flexible with ferrule without plastic sleeve0.25 mm² ... 4 mm²
flexible with ferrule with plastic sleeve0.25 mm² ... 4 mm²
rigid (AWG)24 ... 10 (Cu)
Stripping length8 mm
Tightening torque0.5 Nm ... 0.6 Nm
Tightening torque4 lbf-in. ... 5 lbf-in.
Drive form screw headSlotted L

Signal

Position3.x
Identification3.1 (13), 3.2 (14)

Conductor connection

Connection MethodScrew connection
rigid0.2 mm² ... 6 mm²
flexible0.2 mm² ... 4 mm²
flexible with ferrule without plastic sleeve0.25 mm² ... 4 mm²
flexible with ferrule with plastic sleeve0.25 mm² ... 4 mm²
rigid (AWG)24 ... 10 (Cu)
Stripping length8 mm
Tightening torque0.5 Nm ... 0.6 Nm
Tightening torque4 lbf-in. ... 5 lbf-in.
Drive form screw headSlotted L

LED signaling

Types of signalingLED DC OK – signal state operation (UN = 24 V DC, IOut = IN)
FunctionVisual operating state display
Colorgreen
LED offSupply voltage input AC not present (Off)
LED on (green), DC OKUOUT > 0,9 x UN (On (green), DC OK)
LED on (flashing green) DC OK < 0.9 x UNUOUT < 0,9 x UN (on (flashing green))

Electrical properties

Number of phases1.00
Insulation voltage input/output4 kV AC (type test)
Insulation voltage input/output3 kV AC (routine test)
Insulation voltage input / PE3.5 kV AC (type test)
Insulation voltage input / PE2.4 kV AC (routine test)

Product properties

Product familyUNO POWER
MTBF (IEC 61709, SN 29500)> 900000 h (25 °C)
MTBF (IEC 61709, SN 29500)> 530000 h (40 °C)
MTBF (IEC 61709, SN 29500)> 280000 h (55 °C)
Environmental protection directiveRoHS Directive 2011/65/EU
Environmental protection directiveWEEE
Environmental protection directiveReach

Insulation characteristics

Protection classI
Degree of pollution2

Item dimensions

Width59 mm
Height130 mm
Depth129 mm
Depth125 mm (Device depth (DIN rail mounting))

Installation dimensions

Installation distance right/left (active, passive)0 mm / 0 mm (POut ≥50% )
Installation distance top/bottom (active, passive)30 mm / 30 mm (POut ≥50% )

Mounting

Mounting TypeDIN rail mounting
Assembly instructionsalignable: 0 mm horizontally, 30 mm vertically
Mounting Positionhorizontal DIN rail NS 35, EN 60715
With protective coatingNo

Material specifications

Flammability rating according to UL 94V0 (Housing, terminal blocks)
Housing MaterialMetal
Housing MaterialAluminum (AlMg3) / sheet steel, zinc-plated
Hood versionStainless steel
Side element versionAluminum
Foot latch materialSheet steel, zinc-plated

Ambient conditions

Degree of ProtectionIP20
Ambient Temperature (Operation)-25 °C ... 70 °C (> 55 °C Derating: 2.5 %/K)
Ambient temperature (storage/transport)-40 °C ... 85 °C
Ambient temperature (start-up type tested)-40 °C
Maximum altitude≤ 3000 m (> 2000 m, Derating: 10 %/1000 m)
Max. permissible relative humidity (operation)≤ 95 % (at 25 °C, non-condensing)
Shock (operation)18 ms, 30g, per spatial direction (IEC 60068-2-27)
Vibration (Operation)10 Hz ... 50 Hz, amplitude ±0.2 mm
Vibration (Operation)50 Hz to 150 Hz, 2.3 g, 90 min.

Overvoltage category

EN 61010-1II (≤ 3000 m)
EN 62477-1III (≤3000 m)

Safety of power supply units up to 1100 V (insulation distances)

Standard designationSafety of power supply units up to 1100 V (insulation distances)
Standards/specificationsDIN EN 61558-2-16

Electrical safety

Standard designationElectrical safety
Standards/specificationsIEC 61010-2-201 (SELV)

Electronic equipment for use in power installations

Standard designationEquipping high voltage installations with electronic equipment
Standards/specificationsEN 50178/VDE 0160 (PELV)

Safety for measurement, control, and laboratory equipment

Standard designationSafety for equipment for measurement, control, and laboratory use
Standards/specificationsIEC 61010-1

Protective extra-low voltage

Standard designationProtective extra-low voltage
Standards/specificationsIEC 61010-1 (SELV)
Standards/specificationsIEC 61010-2-201 (PELV)

Safe isolation

Standard designationSafe isolation
Standards/specificationsIEC 61558-2-16
Standards/specificationsIEC 61010-2-201

Limitation of harmonic line currents

Standard designationLimitation of harmonic line currents
Standards/specificationsEN 61000-3-2

Mains voltage dips

Standard designationRequirement of the semiconductor industry with regard to mains voltage dips
Standards/specificationsSEMI F47 - 0706 (185 V AC)

UL

IdentificationUL/C-UL Listed UL 61010-1
IdentificationUL/C-UL Listed UL 61010-2-201
IdentificationUL/C-UL Listed ANSI/UL 121201 Class I, Division 2, Groups A, B, C, D (Hazardous Location)

SIQ

IdentificationCB scheme (IEC 61010-1, IEC 61010-2-201)

EMC data

Low Voltage DirectiveConformance with Low Voltage Directive 2014/35/EC
Interference emissionInterference emission in accordance with EN 61000-6-3 (residential and commercial) and EN 61000-6-4 (industrial)
EMC requirements for noise immunityEN 61000-6-2
Electromagnetic compatibilityConformance with EMC Directive 2014/30/EU
Conducted noise emissionEN 55016
Conducted noise emissionEN 61000-6-3 (Class B)
Noise emissionEN 55016
Noise emissionEN 61000-6-3 (Class B)

Harmonic currents

Standards/regulationsEN 61000-3-2
Standards/regulationsEN 61000-3-2 (Class A)
Frequency Range0 kHz ... 2 kHz

Flicker

Standards/regulationsEN 61000-3-3
Frequency Range0 kHz ... 2 kHz

Electrostatic discharge

Standards/regulationsEN 61000-4-2
Contact discharge6 kV (Test Level 3)
Discharge in air8 kV (Test Level 3)
CommentsCriterion A

Electromagnetic HF field

Standards/regulationsEN 61000-4-3
Frequency Range80 MHz ... 1 GHz
Test field strength10 V/m (Test Level 3)
Frequency Range1 GHz ... 6 GHz
Test field strength10 V/m (Test Level 3)
CommentsCriterion A

Fast transients (burst)

Standards/regulationsEN 61000-4-4
Input4 kV (Test Level 4 - asymmetrical)
Output2 kV (Test Level 3 - asymmetrical)
CommentsCriterion A

Surge voltage load (surge)

Standards/regulationsEN 61000-4-5
Input1 kV (Test Level 3 - symmetrical)
Input2 kV (Test Level 3 - asymmetrical)
Output0.5 kV (Test Level 2 - symmetrical)
Output1 kV (Test Level 2 - asymmetrical)
CommentsCriterion B

Conducted interference

Standards/regulationsEN 61000-4-6
Input/Outputasymmetrical
Frequency Range0.15 MHz ... 80 MHz
CommentsCriterion A
Voltage10 V (Test Level 3)

Voltage dips

Standards/regulationsEN 61000-4-11
Voltage230 V AC
Frequency50 Hz
Voltage dip70 %
Number of periods25 / 30 periods
CommentsCriterion A
Voltage dip40 %
Number of periods12 periods
Additional textTest Level 2
CommentsCriterion A
Voltage dip0 %
Number of periods1 period
Additional textTest Level 2
CommentsCriterion B

Criteria

Criterion ANormal operating behavior within the specified limits.
Criterion BTemporary impairment to operational behavior that is corrected by the device itself.
Accessories

Why Proax for Phoenix Contact UNO2-PS/1AC/24DC/480W?

Proax is an authorized distributor of Phoenix Contact UNO2-PS/1AC/24DC/480W and one of Phoenix Contact's largest distributors in North America. Our highly skilled in-house technical team is ready to assist with any technical needs.

Have a question in mind? to help you get the right product as quickly as possible for your project. We're always here to help!

Short Lead Time
Highly Trained Staff
Live Chat
Technical Support
Local Inventory
60+ Years Experience
Additional Information

Alternate NamesUNO2PS1AC24DC480W
Pack Size1
Recommended

Available for order