Official Distributor
SKU
MPN
2905229
Weight
0.091 kg
Series PLT-SEC-T3
PLT-SEC-T3-230-FM - Type 3 surge protection device
Pluggable device protection, according to type 3/class III, for 1-phase power supply networks with separate N and PE (3-conductor system: L1, N, PE), with integrated surge-proof fuse and remote indication contact. Also suitable for DC applications.
Technical Specifications
Product properties
Product family | SEC Family |
IEC power supply system | TT |
IEC power supply system | TN-S |
Type | DIN rail module, two-section, divisible |
Number of Positions | 2 |
Surge protection fault message | Optical, remote indicator contact |
Insulation characteristics
Overvoltage category | III |
Pollution degree | 2 |
IEC test classification | III |
IEC test classification | T3 |
EN type | T3 |
Number of Ports | One |
Indicator/remote signaling
Connection name | Remote fault indicator contact |
Switching function | N/C contact |
Operating Voltage | 250 V AC |
Operating Voltage | 125 V DC (200 mA DC) |
Operating current | 3 A AC |
Operating current | 1 A DC (30 V DC) |
Connection data
Connection Method | Screw connection |
Screw thread | M3 |
Tightening torque | 0.8 Nm |
Conductor cross section flexible | 0.2 mm² ... 2.5 mm² |
Conductor cross section rigid | 0.2 mm² ... 4 mm² |
Conductor cross section AWG | 24 ... 12 |
Dimensions
Width | 17.7 mm |
Height | 90 mm |
Depth | 74.5 mm (incl. DIN rail 7.5 mm) |
Horizontal pitch | 1 Div. |
Material specifications
Flammability rating according to UL 94 | V-0 |
CTI value of material | 600 |
Insulating material | PA 6.6-FR 20% GF |
Insulating material | PA 6.6-FR |
Material group | I |
Housing Material | PA 6.6-FR 20 % GF |
Housing Material | PA 6.6-FR |
Protective circuit
Mode of protection | L-N |
Mode of protection | L-PE |
Mode of protection | N-PE |
Mode of protection | (L+) - (L-) |
Mode of protection | (L+/L-) - PE |
Direction of action | 1L-N & N-PE |
Nominal voltage UN | 230 V AC (TN-S) |
Nominal voltage UN | 230 V AC (TT - only in use with RCD) |
Nominal frequency fN | 50 Hz (60 Hz) |
Maximum continuous voltage UC | 264 V AC |
Maximum continuous voltage UC | 230 V DC |
Rated load current IL | 26 A (30 °C) |
Residual current IPE | ≤ 5 µA |
Standby power consumption PC | ≤ 275.00 mVA (at UREF) |
Standby power consumption PC | ≤ 300.00 mVA (at UC) |
Reference test voltage UREF | 255.00 V AC |
Nominal discharge current In (8/20) µs | 3 kA |
Combination wave UOC | 6 kV |
Voltage protection level Up (L-N) | ≤ 1.35 kV |
Voltage protection level Up (L-PE) | ≤ 1.5 kV |
Voltage protection level Up (N-PE) | ≤ 1.5 kV |
TOV behavior at UT (L-N) | 440 V AC (5 s / withstand mode) |
TOV behavior at UT (L-N) | 440 V AC (120 min / withstand mode) |
TOV behavior at UT (L-PE) | 440 V AC (5 s / withstand mode) |
TOV behavior at UT (L-PE) | 440 V AC (120 min / withstand mode) |
TOV behavior at UT (L-PE) | 1455 V AC (200 ms / safe failure mode) |
TOV behavior at UT (N-PE) | 1200 V AC (200 ms / safe failure mode) |
Response time tA (L-N) | ≤ 25 ns |
Response time tA (L-PE) | ≤ 100 ns |
Response time tA (N-PE) | ≤ 100 ns |
Short-circuit current rating ISCCR | 1.5 kA AC |
Short-circuit current rating ISCCR | 0.25 kA DC |
Max. backup fuse with branch wiring | not required |
Ambient conditions
Degree of Protection | IP20 |
Ambient Temperature (Operation) | -40 °C ... 80 °C |
Ambient temperature (storage/transport) | -40 °C ... 80 °C |
Altitude | ≤ 2000 m (amsl) |
Permissible humidity (operation) | 5 % ... 95 % |
Shock (operation) | 30g (Half-sine / 11 ms / 3x ±X, ±Y, ±Z) |
Vibration (Operation) | 5g (10 ... 150 Hz/20 cycles/axis/X, Y, Z) |
UL specifications
Maximum continuous operating voltage MCOV | 255 V AC |
Maximum continuous operating voltage MCOV | 230 V DC |
Nominal discharge current In | 3 kA |
Mode of protection | L-N |
Mode of protection | L-G |
Mode of protection | N-G |
Mode of protection | (L+) - (L-) |
Mode of protection | (L+) - G |
Mode of protection | (L-) - G |
Nominal Voltage | 230 V DC |
Rated load current IL | 25 A |
Power distribution system | Single phase |
Nominal frequency | 50/60 Hz |
Measured limiting voltage MLV (L-N) | 1290 V |
Measured limiting voltage MLV (L-G) | 1310 V |
Measured limiting voltage MLV (N-G) | 1310 V |
Measured limiting voltage MLV (L+) - (L-) | 1290 V |
Measured limiting voltage MLV (L+) - G | 1310 V |
Measured limiting voltage MLV (L-) - G | 1310 V |
SPD Type | 4CA |
UL connection data
Tightening torque | 5 lbf-in. ... 7 lbf-in. |
Conductor cross section AWG | 14 ... 12 |
Standards and Regulations
Standards/specifications | IEC 61643-11 |
Note | 2011 |
EN 61643-11
Standards/specifications | EN 61643-11 |
Note | 2012 |
Mounting
Mounting Type | DIN rail: 35 mm |
Accessories
Why Proax for Phoenix Contact PLT-SEC-T3-230-FM?
Proax is an authorized distributor of Phoenix Contact PLT-SEC-T3-230-FM and one of Phoenix Contact's largest distributors in North America. Our highly skilled in-house technical team is ready to assist with any technical needs.
Have a question in mind? to help you get the right product as quickly as possible for your project. We're always here to help!
Short Lead Time
Highly Trained Staff
Live Chat
Technical Support
Local Inventory
60+ Years Experience
Additional Information
Alternate Names | PLTSECT3230FM |
Pack Size | 1 |
Recommended