PLT-SEC-T3-120-P-UT/PT - Type 3 surge protection plug
Replacement plug for type 2/3 surge protection from the PLT-SEC-…-UT/PT product series. Nominal voltage 120 V.
Technical Specifications
Product properties
Product family | SEC Family |
IEC power supply system | TN-S |
IEC power supply system | TT |
Type | Male |
Number of Positions | 2 |
Surge protection fault message | optical |
Insulation characteristics
Overvoltage category | III |
Pollution degree | 2 |
IEC test classification | II / III |
IEC test classification | T2 / T3 |
EN type | T2 / T3 |
Number of Ports | One |
Connection data
Connection Method | pluggable |
Dimensions
Width | 17.5 mm |
Height | 46.7 mm |
Depth | 65.7 mm |
Horizontal pitch | 1 Div. |
Material specifications
Color | light grey (RAL 7035) |
Color | gray (RAL 7042) |
Flammability rating according to UL 94 | V-0 |
CTI value of material | 600 |
Insulating material | PA 6.6-FR 20 % GF |
Insulating material | PA 6.6-FR |
Housing Material | PA 6.6-FR 20 % GF |
Housing Material | PA 6.6-FR |
Protective circuit
Mode of protection | L-N |
Mode of protection | L-PE |
Mode of protection | N-PE |
Direction of action | 1L-N & N-PE |
Nominal voltage UN | 120 V AC (TN-S) |
Nominal voltage UN | 120 V AC (TT) |
Nominal frequency fN | 50 Hz (60 Hz) |
Maximum continuous voltage UC | 150 V AC |
Residual current IPE | ≤ 5 µA |
Standby power consumption PC | ≤ 10.60 mVA (at UREF) |
Standby power consumption PC | ≤ 13.50 mVA (at UC) |
Reference test voltage UREF | 132.00 V AC |
Nominal discharge current In (8/20) µs | 5 kA |
Maximum discharge current Imax (8/20) µs | 10 kA |
Combination wave UOC | 6 kV |
Voltage protection level Up (L-N) | ≤ 0.75 kV (at UOC) |
Voltage protection level Up (L-N) | ≤ 0.95 kV (at In) |
Voltage protection level Up (L-PE) | ≤ 0.85 kV |
Voltage protection level Up (N-PE) | ≤ 0.85 kV |
TOV behavior at UT (L-N) | 240 V AC (5 s / withstand mode) |
TOV behavior at UT (L-N) | 240 V AC (120 min / withstand mode) |
TOV behavior at UT (L-PE) | 240 V AC (5 s / withstand mode) |
TOV behavior at UT (L-PE) | 240 V AC (120 min / withstand mode) |
TOV behavior at UT (L-PE) | 1332 V AC (200 ms / safe failure mode) |
TOV behavior at UT (N-PE) | 1200 V AC (200 ms / safe failure mode) |
Response time tA (L-N) | ≤ 25 ns |
Response time tA (L-PE) | ≤ 100 ns |
Response time tA (N-PE) | ≤ 100 ns |
Short-circuit current rating ISCCR | 10 kA AC |
Max. backup fuse with branch wiring | 32 A (gG / B / C) |
Additional technical data
Short-circuit current rating ISCCR | 0.25 kA DC (Without additional backup fuse in the DC branch wiring) |
Short-circuit current rating ISCCR | 5 kA DC (for 20 A gG / B backup fuse) |
Residual voltage Ures (L-N) | ≤ 0.68 kV (at 2 kA) |
Residual voltage Ures (L-N) | ≤ 0.75 kV (at 3 kA) |
Residual voltage Ures (L-N) | ≤ 0.64 kV (at UOC = 4 kV) |
Residual voltage Ures (L-PE) | ≤ 0.58 kV (at 2 kA) |
Residual voltage Ures (L-PE) | ≤ 0.65 kV (at 3 kA) |
Residual voltage Ures (L-PE) | ≤ 0.75 kV (at UOC = 4 kV) |
Residual voltage Ures (N-PE) | ≤ 0.58 kV (at 2 kA) |
Residual voltage Ures (N-PE) | ≤ 0.65 kV (at 3 kA) |
Residual voltage Ures (N-PE) | ≤ 0.75 kV (at UOC = 4 kV) |
Maximum continuous voltage UC | 150 V DC |
Mode of protection | (DC+) - (DC-) |
Mode of protection | (DC+/DC-) - PE |
IEC test classification (in accordance with IEC 61643-21) | D1 |
Impulse durability (wire-wire) | D1 - 500 A |
Impulse durability (line-earth) | D1 - 500 A |
Pulse discharge current Iimp (10/350) µs (line-line) | 0.5 kA |
Pulse discharge current Iimp (10/350) µs (line-earth) | 0.5 kA |
Ambient conditions
Degree of Protection | IP20 |
Ambient Temperature (Operation) | -40 °C ... 80 °C |
Ambient temperature (storage/transport) | -40 °C ... 80 °C |
Altitude | ≤ 6000 m (amsl) |
Permissible humidity (operation) | 5 % ... 95 % |
Shock (operation) | 30g (Half-sine / 11 ms / 3x ±X, ±Y, ±Z) |
Vibration (Operation) | 5g (5 ... 500 Hz / 2.5 h / X, Y, Z) |
UL specifications
Maximum continuous operating voltage MCOV | 150 V AC |
Maximum continuous operating voltage MCOV | 150 V DC |
Short-circuit current rating (SCCR) | 10 kA AC |
Short-circuit current rating (SCCR) | 5 kA DC |
Voltage protection rating VPR (L-N) | 800 V |
Voltage protection rating VPR (L-G) | 900 V |
Voltage protection rating VPR (N-G) | 900 V |
Voltage protection rating VPR (DC+) - (DC-) | 700 V |
Voltage protection rating VPR (DC+) - G | 900 V |
Voltage protection rating VPR (DC-) - G | 900 V |
Nominal discharge current In | 5 kA |
Mode of protection | L-N |
Mode of protection | L-G |
Mode of protection | N-G |
Mode of protection | (DC+) - (DC-) |
Mode of protection | (DC+) - G |
Mode of protection | (DC-) - G |
Nominal Voltage | 150 V DC |
Rated load current IL | 20 A |
Power distribution system | Single phase |
Power distribution system | DC |
Nominal frequency | 50/60 Hz |
SPD Type | 2CA |
Standards and Regulations
Standards/specifications | IEC 61643-11 |
Note | 2011 |
EN 61643-11
Standards/specifications | EN 61643-11 |
Note | 2012 |
Mounting
Mounting Type | on base element |
Why Proax for Phoenix Contact 2907922?
Proax is an authorized distributor of Phoenix Contact 2907922 and one of Phoenix Contact's largest distributors in North America. Our highly skilled in-house technical team is ready to assist with any technical needs.
Have a question in mind? to help you get the right product as quickly as possible for your project. We're always here to help!
Short Lead Time
Highly Trained Staff
Live Chat
Technical Support
Local Inventory
60+ Years Experience
Additional Information
Pack Size | 1 |
Recommended