Official Distributor
SKU
MPN
PLC-RPT- 24DC/21-21/MS
Weight
0.075 kg
This product is Not Cancellable/Not Returnable
Series PLC-RPT
PLC-RPT- 24DC/21-21/MS - Relay Module
PLC-INTERFACE, consisting of a relay base and pluggable power contact relay with manual operation, integrated status LED and freewheeling diode, Push-in connection, 2 changeover contacts, Freewheeling diode, Input voltage: 24 V DC
Technical Specifications
Product properties
Product family | PLC-INTERFACE |
Application | Palm switch |
Operating mode | 100% operating factor |
Mechanical service life | 5x 106 cycles |
Insulation characteristics
Insulation | Safe isolation, reinforced insulation |
Insulation characteristics: Air clearances and creepage distances between the power circuits
Insulation | Safe isolation, reinforced insulation |
Overvoltage category | III |
Pollution degree | 2 |
Electrical properties
Maximum power dissipation for nominal condition | 0.44 W |
Test voltage (Winding/contact) | 4 kVrms (50 Hz, 1 min.) |
Test voltage (Changeover contact/changeover contact) | 2.5 kVrms (50 Hz, 1 min.) |
Air clearances and creepage distances between the power circuits
Rated Insulation Voltage | 250 V AC |
Rated surge voltage | 6 kV |
Coil side
Nominal input voltage UN | 24 V DC |
Input voltage range | 20.2 V DC ... 33.6 V DC (20 °C) |
Drive and function | monostable |
Drive (polarity) | polarized |
Typical input current at UN | 18 mA |
Typical response time | 10 ms |
Typical release time | 10 ms |
Coil Voltage | 24 V DC |
Protective circuit | Surge protection; Freewheeling diode |
Operating voltage display | Yellow LED |
Switching
Contact switching type | 2 changeover contacts |
Type of switch contact | Single contact |
Contact Material | AgNi |
Maximum Switching Voltage | 250 V AC/DC (The separating plate PLC-ATP should be installed for voltages larger than 250 V (L1, L2, L3) between identical terminal blocks in adjacent modules. Potential bridging is then carried out with FBST 8-PLC... or ...FBST 500...) |
Minimum Switching Voltage | 12 V (10 mA) |
Limiting Continuous Current | 6 A |
Maximum Inrush Current | 12 A (20 ms) |
Min. switching current | 10 mA (12 V) |
Interrupting rating (ohmic load) max. | 192 W (24 V DC) |
Interrupting rating (ohmic load) max. | 62 W (48 V DC) |
Interrupting rating (ohmic load) max. | 42 W (60 V DC) |
Interrupting rating (ohmic load) max. | 55 W (110 V DC) |
Interrupting rating (ohmic load) max. | 66 W (220 V DC) |
Interrupting rating (ohmic load) max. | 2000 VA (250 V AC) |
Switching capacity | 1 A (24 V, DC13) |
Switching capacity | 1.5 A (230 V, AC15) |
Connection data
Connection Method | Push-in connection |
Stripping length | 10 mm |
Conductor cross section rigid | 0.14 mm² ... 2.5 mm² |
Conductor cross section flexible | 0.14 mm² ... 2.5 mm² |
Conductor cross section flexible | 0.2 mm² ... 2.5 mm² (Single ferrule) |
Conductor cross section flexible | 2x 0.5 mm² ... 1 mm² (TWIN ferrule) |
Conductor cross section AWG | 26 ... 14 |
Dimensions
Width | 14 mm |
Height | 80 mm |
Depth | 104 mm |
Material specifications
Color | gray (RAL 7042) |
Flammability rating according to UL 94 | V0 (Housing) |
Ambient conditions
Degree of protection (Relay) | RT II |
Degree of protection (Relay base) | IP20 |
Degree of protection (Installation location) | ≥ IP54 |
Ambient Temperature (Operation) | -40 °C ... 60 °C |
Ambient temperature (storage/transport) | -40 °C ... 85 °C |
Altitude | ≤ 2000 m |
CE
Certificate | CE-compliant |
UKCA
Certificate | UKCA-compliant |
UL, USA
Identification | UL 508 |
Identification | UL 508 Recognized |
UL, USA/Canada
Identification | UL 508 |
Identification | UL 508 Recognized |
Shipbuilding approval
Certificate | TAE0000196 |
Corrosive gas test
Identification | ISA-S71.04. G3 Harsh Group |
Identification | EN 60068-2-60 |
DNV GL data
Temperature | D |
Humidity | A |
Vibration | B/C |
EMC | B |
Enclosure | Required protection according to the Rules shall be provided upon installation on board |
EMC data
Low Voltage Directive | Conformance with Low Voltage Directive |
Electromagnetic compatibility | Conformance with EMC directive |
Air clearances and creepage distances between the power circuits
Standards/regulations | IEC 60947-5-1 |
Mounting
Mounting Type | DIN rail mounting |
Assembly instructions | in rows with zero spacing |
Mounting Position | any |
Accessories
- 2299660 - V8 adapter for 8 x PLC-INTERFACE (14 mm), controller: PLC system cabling of output cards, connection 1: IDC/FLK pin strip 1x 14-position, connection 2: Plug-in connection (Can be snapped onto 8x PLC-INTERFACE terminals), connection 3: Screw connection 1x 2-position, number of channels: 8, control logic: plusschaltend
- 2304306 - V8 adapter for 8 x PLC-INTERFACE (14 mm), controller: PLC system cabling of output cards, connection 1: IDC/FLK pin strip 1x 14-position, connection 2: Plug-in connection (Can be snapped onto 8x PLC-INTERFACE terminals), connection 3: Screw connection 1x 2-position, number of channels: 8, control logic: minusschaltend
Why Proax for Phoenix Contact 2910519?
Proax is an authorized distributor of Phoenix Contact 2910519 and one of Phoenix Contact's largest distributors in North America. Our highly skilled in-house technical team is ready to assist with any technical needs.
Have a question in mind? to help you get the right product as quickly as possible for your project. We're always here to help!
Short Lead Time
Highly Trained Staff
Live Chat
Technical Support
Local Inventory
60+ Years Experience
Additional Information
Pack Size | 10 |
Recommended