Proax

Currency
0 Items
proax logo
Cart
Phoenix ContactOfficial Distributor

By Phoenix Contact

SKU
MPN
1328360
Weight
0.04 kg
Series PLC-RPT

PLC-RPT- 24DC/1/CB1-6 - Electronic circuit breaker

Combination of relay interface and electronic fuse protection on overall width: 6.2 mm, individual configuration of the nominal current (1 A ... 6 A), adjustable output characteristic, active signal output, easy system integration, with Push-in connection

Technical Specifications

Notes

Notes on operationRepeated hard short circuits can reduce the melting integral of the integrated backup fuse.
Notes on operationA suitable flyback diode must be used when switching inductive loads
Notes on operationIf the DIP switches are not covered by an adjacent module, the PLC-ATP partition plate must be used for ESD protection
Notes on operationThe device contains components that can be damaged or destroyed by electrostatic discharge. When handling the device, observe the necessary safety precautions against electrostatic discharge (ESD) according to EN 61340-5-1 and EN 61340-5-1.
Notes on operationThe PLC-ATP separating plate should be installed for safe isolation between adjacent modules
Notes on operationDo not connect adjacent channels to SELV/ PELV and voltages dangerous to the touch.
Notes on operationAt least one functional insulation against adjacent modules is complied with in the support rail direction.If the application has higher requirements on the insulation (basic or reinforced insulation), then these must be realized through suitable measures (e. g., partition plates).
Notes on operationDo not use to separate SELV / PELV circuits from other circuits, because safe isolation is not guaranteed.

Product properties

Product familyPLC-INTERFACE
Operating mode100% operating factor

Insulation characteristics: Air clearances and creepage distances

InsulationFunctional insulation
Overvoltage categoryI
Pollution degree2

Electrical properties

Maximum power dissipation for nominal condition< 1.6 W
Fuseelectronic

Input data

Operating voltage (UN)24 V DC (UIn+ - UA2)
Operating voltage range (DC)19.2 V DC ... 30 V DC (UIn+ - UA2)
Current consumption (In+)12 mA
Tripping current (IN)1 A (adjustable)
Tripping current (IN)2 A (adjustable)
Tripping current (IN)3 A (adjustable)
Tripping current (IN)4 A (adjustable)
Tripping current (IN)5 A (adjustable)
Tripping current (IN)6 A (preset)
Measuring tolerance± 15 %
Power dissipation0.06 W (Without load, A1 low)
Power dissipation0.4 W (Without load, A1 high)
Power dissipation< 1.6 W (Normal operation)

Switching: Switching input A1

Nominal switch-on voltage24 V (UA1 - UA2)
Switch-on voltage range11 V ... 30 V (UA1 - UA2)
Switch-off voltage range0 V ... 2 V (UA1 - UA2)
Current consumption (IA1)4 mA (24 V)
Switch-on time36 ms
Switch-off time10 ms
Switching frequency≤ 2.5 Hz

Load circuit: Power MOSFET switching output (positive switching)

Voltage drop0.16 V (6 A, UIn+ - Uout)
Short-circuit switching capacity100 A DC
Short-circuit switching capacity300 A DC (<5 short circuits)
Required backup fuseOnly required if Imax of power supply unit > short-circuit switching capacity. Integrated failsafe element
Fail-safe element15 A
Surge voltage protection> 33 V
Max. capacitive load12000 µF (Depending on the current setting and the short-circuit current available)
Shutdown time ()≤ 15 ms (Short circuit ≥3 x IN)
Shutdown time ()0.1 s (Short circuit 2 ... <3 x IN)
Shutdown time ()1 s (Short circuit 1.5 ... <2 x IN)
Shutdown time ()4 s (Short circuit 1.1 ... <1.5 x IN)
Undervoltage switch-off≤ 17.8 V (active)
Undervoltage switch-off≥ 19 V (inactive)
Overvoltage switch-off≥ 30.5 V (active)
Overvoltage switch-off≤ 29.5 V (inactive)
Waiting time5 s (Between the pulses)
Number5 (Start attempts in hiccup mode)

Signal: Feedback contact

Output VoltageUIn+ - 0.7 V (high level)
Current (Maximum current)≤ 20 mA
State condition (Normal operation)low
State condition (Error)high (Fuse has blown)
State condition (Hiccup mode)high (After all 5 start attempts have been completed)

Connection data

Connection MethodPush-in connection
Stripping length8 mm
Conductor cross section rigid0.14 mm² ... 1.5 mm²
Conductor cross section flexible0.14 mm² ... 1.5 mm²
Conductor cross section flexible (2 conductors with same cross section)0.5 mm² ... 1.5 mm² (TWIN ferrule with plastic sleeve)
Conductor cross section AWG26 ... 14

Item dimensions

Width6.2 mm
Height96 mm
Depth75 mm

Ambient conditions

Degree of ProtectionIP20
Degree of protection (Installation location)≥ IP54
Ambient Temperature (Operation)-25 °C ... 55 °C (Observe derating in the connected state)
Ambient temperature (storage/transport)-40 °C ... 70 °C
Altitude≤ 2000 m (Without derating)
Altitude≤ 3000 m (With correction factor for ambient temperature (operation) x 0.88)
Permissible humidity (operation)95 %

UL, USA/Canada

IdentificationUL 2367
IdentificationUL 60947-1
IdentificationUL 60947-5-1
IdentificationCSA C22.2 No. 60947-1
IdentificationCSA C22.2 No. 60947-5-1

UL data

Operating modeIndoor use

Electromagnetic compatibility (EMC)

Standards/regulationsEN 61000-6-2
Standards/regulationsEN 61000-6-3

Air clearances and creepage distances

Standards/regulationsIEC 60664

Mounting

Mounting TypeDIN rail mounting
Assembly instructionsin rows with zero spacing
Mounting Positionany

Why Proax for Phoenix Contact PLC-RPT- 24DC/1/CB1-6?

Proax is an authorized distributor of Phoenix Contact PLC-RPT- 24DC/1/CB1-6 and one of Phoenix Contact's largest distributors in North America. Our highly skilled in-house technical team is ready to assist with any technical needs.

Have a question in mind? to help you get the right product as quickly as possible for your project. We're always here to help!

Short Lead Time
Highly Trained Staff
Live Chat
Technical Support
Local Inventory
60+ Years Experience
Additional Information

Alternate NamesPLCRPT24DC1CB16
Pack Size1
Recommended

Available for order