2907919
PHX2907919
Official Distributor
Type 3 surge protection device - PLT-SEC-T3-230-FM-UT
Type 2/3 surge protection, consisting of protective plug and base element with screw connection. For single-phase power supply network with integrated status indicator and remote signaling. Nominal voltage: 230 V AC/DC
- Surge protection family for universal use with optimum energy coordination from the lightning current arrester to the device protection
- Easy to maintain due to consistently pluggable protection modules
- Excellent level of information provided by mechanical/visual status indicator and remote indication contact
- Your preferred connection technology can be selected as both screw connection and Push-in connection are available
- Optimal additional protection of the industrial power supply for a longer service life and increased availability of the system
- 5-year warranty on your QUINT 4 power supply when installed together with PLT-SEC, see document in the download area
Technical Specifications
Dimensions
Height | 93.4 mm |
Width | 17.7 mm |
Depth | 74.5 mm (incl. DIN rail 7.5 mm) |
Horizontal pitch | 1 Div. |
Ambient conditions
Degree of Protection | IP20 |
Ambient Temperature (Operation) | -40 °C ... 80 °C |
Ambient temperature (storage/transport) | -40 °C ... 80 °C |
Altitude | ≤ 2000 m (operating voltage remote contact ≤ 250 V) |
Altitude | ≤ 6000 m (operating voltage remote contact ≤ 150 V) |
Permissible humidity (operation) | 5 % ... 95 % |
Shock (operation) | 30g (Half-sine / 11 ms / 3x ±X, ±Y, ±Z) |
Vibration (Operation) | 5g (5 ... 500 Hz / 2.5 h / X, Y, Z) |
General
EN type | T2 / T3 |
IEC power supply system | TT |
IEC power supply system | TN-S |
Number of Ports | One |
Mode of protection | L-N |
Mode of protection | L-PE |
Mode of protection | N-PE |
Mounting Type | DIN rail: 35 mm |
Color | light grey RAL 7035 |
Color | traffic grey A RAL 7042 |
Housing Material | PA 6.6-FR 20 % GF |
Housing Material | PA 6.6-FR |
Degree of pollution | 2 |
Flammability rating according to UL 94 | V-0 |
Type | DIN rail module, two-section, divisible |
Number of Positions | 2 |
Surge protection fault message | Optical, remote indicator contact |
Protective circuit
Nominal voltage UN | 240 V AC (TN-S) |
Nominal voltage UN | 240 V AC (TT) |
Nominal frequency fN | 50 Hz (60 Hz) |
Maximum continuous voltage UC | 264 V AC |
Rated load current IL | 26 A (at 30 °C) |
Residual current IPE | ≤ 5 µA |
Nominal discharge current In (8/20) µs | 5 kA |
Standby power consumption PC | ≤ 26.4 mVA (at UREF) |
Standby power consumption PC | ≤ 26.4 mVA (at UC) |
Reference test voltage UREF | 264 V AC |
Max. discharge current Imax (8/20) µs | 10 kA |
Combination wave UOC | 6 kV |
Voltage protection level Up (L-N) | ≤ 1.25 kV (at UOC) |
Voltage protection level Up (L-N) | ≤ 1.4 kV (at In) |
Voltage protection level Up (L-PE) | ≤ 1.4 kV |
Voltage protection level Up (N-PE) | ≤ 1.4 kV |
TOV behavior at UT (L-N) | 400 V AC (5 s / withstand mode) |
TOV behavior at UT (L-N) | 457 V AC (120 min / safe failure mode) |
TOV behavior at UT (L-PE) | 457 V AC (5 s / withstand mode) |
TOV behavior at UT (L-PE) | 457 V AC (120 min / withstand mode) |
TOV behavior at UT (L-PE) | 1464 V AC (200 ms / safe failure mode) |
TOV behavior at UT (N-PE) | 1200 V AC (200 ms / safe failure mode) |
Response time tA (L-N) | ≤ 25 ns |
Response time tA (L-PE) | ≤ 100 ns |
Response time tA (N-PE) | ≤ 100 ns |
Short-circuit current rating ISCCR | 10 kA AC |
Max. backup fuse with branch wiring | 32 A (gG / B / C) |
Maximum backup fuse for through wiring | 25 A (gG / B / C) |
Additional technical data
Short-circuit current rating ISCCR | 0.25 kA DC (Without additional backup fuse in the DC branch wiring) |
Short-circuit current rating ISCCR | 5 kA DC (for 20 A gG / B backup fuse) |
Maximum continuous voltage UC | 275 V AC |
Maximum continuous voltage UC | 240 V DC |
Residual voltage Ures (L-N) | ≤ 1.15 kV (at 2 kA) |
Residual voltage Ures (L-N) | ≤ 1.25 kV (at 3 kA) |
Residual voltage Ures (L-N) | ≤ 1.1 kV (at UOC = 4 kV) |
Residual voltage Ures (L-PE) | ≤ 1.1 kV (at 2 kA) |
Residual voltage Ures (L-PE) | ≤ 1.1 kV (at 3 kA) |
Residual voltage Ures (L-PE) | ≤ 1.2 kV (at UOC = 4 kV) |
Residual voltage Ures (N-PE) | ≤ 1.1 kV (at 2 kA) |
Residual voltage Ures (N-PE) | ≤ 1.1 kV (at 3 kA) |
Residual voltage Ures (N-PE) | ≤ 1.2 kV (at UOC = 4 kV) |
Mode of protection | (DC+) - (DC-) |
Mode of protection | (DC+/DC-) - PE |
IEC test classification (in accordance with IEC 61643-21) | D1 |
Impulse durability (line-line) | D1 - 500 A |
Impulse durability (line-earth) | D1 - 500 A |
Pulse discharge current Iimp (10/350) µs (line-line) | 0.5 kA |
Pulse discharge current Iimp (10/350) µs (line-earth) | 0.5 kA |
Indicator/remote signaling
Switching function | Changeover contact |
Operating Voltage | 250 V AC |
Operating Voltage | 125 V DC (200 mA DC) |
Operating current | 0.5 A AC |
Operating current | 0.5 A DC (75 V DC) |
Connection Method | Screw connection |
Conductor cross section flexible | 0.2 mm² ... 2.5 mm² |
Conductor cross section solid | 0.2 mm² ... 2.5 mm² |
Conductor cross section AWG | 30 ... 12 |
Screw thread | M3 |
Tightening torque | 0.5 Nm |
Stripping length | 10 mm |
Connection data
Connection Method | Screw connection |
Conductor cross section flexible | 0.2 mm² ... 2.5 mm² |
Conductor cross section solid | 0.2 mm² ... 4 mm² |
Conductor cross section AWG | 24 ... 12 |
Screw thread | M3 |
Tightening torque | 0.5 Nm |
Stripping length | 10 mm |
UL specifications
SPD Type | 4CA |
Maximum continuous operating voltage MCOV | 264 V AC |
Maximum continuous operating voltage MCOV | 240 V DC |
Nominal Voltage | 240 V DC |
Rated load current IL | 20 A |
Mode of protection | L-N |
Mode of protection | L-G |
Mode of protection | N-G |
Mode of protection | (DC+) - (DC-) |
Mode of protection | (DC+) - G |
Mode of protection | (DC-) - G |
Power distribution system | Single phase |
Power distribution system | DC |
Nominal frequency | 50/60 Hz |
Measured limiting voltage MLV (L-N) | 1150 V |
Measured limiting voltage MLV (L-G) | 1180 V |
Measured limiting voltage MLV (N-G) | 1180 V |
Nominal discharge current In | 5 kA |
UL indicator/remote signaling
Operating Voltage | 250 V AC (0.5 A) |
Operating Voltage | 12 V DC (4 A) |
Operating Voltage | 24 V DC (2 A) |
Operating Voltage | 48 V DC (1 A) |
Tightening torque | 5 lbf-in. ... 7 lbf-in. |
Conductor cross section AWG | 30 ... 12 |
UL connection data
Conductor cross section AWG | 16 ... 12 |
Tightening torque | 4.4 lbf-in. |
Standards and Regulations
Standards/specifications | IEC 61643-11 2011 |
Standards/specifications | EN 61643-11 2012 |
Environmental Product Compliance
REACh SVHC | Lead 7439-92-1 |
China RoHS | Environmentally Friendly Use Period = 50 years |
China RoHS | For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration” |
Accessories
Why Proax for Phoenix Contact 2907919?
Proax is an authorized distributor of Phoenix Contact 2907919 and one of Phoenix Contact's largest distributors in North America. Our highly skilled in-house technical team is ready to assist with any technical needs.
Have a question in mind? to help you get the right product as quickly as possible for your project. We're always here to help!
Short Lead Time
Highly Trained Staff
Live Chat
Technical Support
Local Inventory
60+ Years Experience
Best Sellersin Surge Protection