Official Distributor
SKU
MPN
AXL E IOL DO8 M12 6P
Weight
0.297 kg
This product is Not Cancellable/Not Returnable
AXL E IOL DO8 M12 6P - Digital module
Axioline E, Digital output device, IO-Link ports Class B: 1, connection method: M12 connector, A-coded, connection technology: 5-conductor, Digital outputs: 8, 24 V DC, 500 mA, connection technology: 3-conductor, Plastic housing, degree of protection: IP65/IP67
- Connection to an IO-Link master with M12 connector (A-coded, 4-pos.)
- Type B port with additional power supply
- IO-Link specification V1.1.2
- Connection up to 8 outputs with M12 connectors (A-coded, 5-pos.)
- Diagnostic and status indicators
- Short-circuit and overload protection of the sensor supply
- Device rating plate stored
- IP65/IP67 degree of protection
Technical Specifications
Dimensions
Width | 60 mm |
Height | 141 mm |
Depth | 20 mm |
Note on dimensions | The height is 170 mm including fixing clips. The depth is 30 mm including the connector. |
Utilization restriction
EMC note | EMC: class A product, see manufacturer's declaration in the download area |
Material specifications
Housing Material | Pocan® |
Color | anthracite grey RAL 7016 |
IO-Link
Number of Ports | 1 |
Connection Method | M12 connector, A-coded |
Connection technology | 5-conductor |
Port Type | Class B |
Specification | V1.1.2 |
Reverse polarity protection | yes |
Transmission Speed | 230.4 kbps (COM3) |
Cycle Time | < 1 ms |
Process data update | < 1 ms |
Amount of Process Data | 16 bit (Output data) |
Digital:
Output name | Digital outputs |
Connection Method | M12 connector |
Connection technology | 3-conductor |
Number of Outputs | 8 |
Protective circuit | Overload protection, short-circuit protection of outputs; Electronic |
Output Voltage | 24 V DC |
Limitation of the voltage induced on circuit interruption | -28 V ... -15 V |
Output Current | max. 500 mA (per port) |
Output Current | max. 4 A (per device) |
Nominal Output Voltage | 24 V DC (from voltage UA) |
Load min. | 10 kΩ |
Output voltage when switched off | max. 1 V |
Output current when switched off | max. 300 µA |
Nominal load, inductive | max. 12 VA (1.2 H, 48 Ω, with nominal voltage) |
Nominal load, lamp | max. 12 W (at nominal voltage) |
Nominal load, ohmic | max. 12 W (48 Ω, with nominal voltage) |
Switching frequency | max. 1000 per second |
Switching frequency | max. 1 per second (with inductive load) |
Switching frequency | max. 16 per second (with nominal lamp load) |
Reverse voltage resistance to short pulses | limited protection up to 0.5 A for 1 s |
Behavior with overload | Auto restart |
Behavior with inductive overload | Output can be destroyed |
Signal delay | max. 100 µs (when switched on) |
Signal delay | max. 100 µs (when switched off, with at least 50 mA load current) |
Overcurrent shut-down | as of 0.7 A |
Output current with ground connection interrupt when switched off | < 1 mA |
Product properties
Product family | Axioline E |
Type | Stand-Alone |
Special Properties | Plastic housing |
Supply: IO-Link
Designation | IO-Link port supply (L+) |
Nominal voltage for I/O supply | 24 V DC (Provided via the IO-Link interface of the IO-Link master.) |
Supply Voltage Range | 20 V DC ... 30 V DC (including all tolerances, including ripple) |
Nominal current per device | approx. 15 mA |
Permissible cable length | max. 20 m |
Protective circuit | Reverse polarity protection; yes |
Supply: Actuators
Designation | Supply of actuators (UA) |
Supply Voltage | 24 V DC (Nominal voltage) |
Supply Voltage Range | 19.2 V DC ... 30 V DC (including all tolerances, including ripple) |
Current consumption | max. 500 mA (per port) |
Current consumption | max. 4 A (Device dependent; observe the current of the IO-Link master that is made available via UA.) |
Electrical isolation/isolation of the voltage ranges
Test voltage: 24 V supply (logic supply)/24 V supply (actuator supply) | 500 V AC, 50 Hz, 1 min. |
Test voltage: 24 V supply (logic supply) / FE | 500 V AC, 50 Hz, 1 min. |
Test voltage: 24 V supply (actuator supply)/FE | 500 V AC, 50 Hz, 1 min. |
Connection data
Connection Method | M12 connector |
Note on the connection method | in accordance with IEC 61076-2-101, M12 connection technology |
Ambient conditions
Ambient Temperature (Operation) | -25 °C ... 60 °C |
Degree of Protection | IP65/IP67 |
Air pressure (operation) | 70 kPa ... 106 kPa (up to 3000 m above sea level) |
Air pressure (storage/transport) | 70 kPa ... 106 kPa (up to 3000 m above sea level) |
Ambient temperature (storage/transport) | -25 °C ... 70 °C |
Permissible humidity (operation) | 5 % ... 95 % |
Permissible humidity (storage/transport) | 5 % ... 95 % |
Standards and Regulations
Protection class | III (IEC 61140, EN 61140, VDE 0140-1) |
Mounting
Mounting Type | Wall mounting |
Why Proax for Phoenix Contact 2702659?
Proax is an authorized distributor of Phoenix Contact 2702659 and one of Phoenix Contact's largest distributors in North America. Our highly skilled in-house technical team is ready to assist with any technical needs.
Have a question in mind? to help you get the right product as quickly as possible for your project. We're always here to help!
Short Lead Time
Highly Trained Staff
Live Chat
Technical Support
Local Inventory
60+ Years Experience
Additional Information
Pack Size | 1 |
Recommended